Pilz P2HZ X1 Data Sheet

Two-hand Relays
EN 574, Type IIIC
P2HZ X1
Two-hand relay in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98.
Features
Conforms to type IIIC in accordance with EN 574 and category 4 in accordance with EN 954-1
Approvals
Technical Details P2HZ X1
Electrical Data
Supply Voltage
Tolerance 85 ... 110 % Power Consumption Approx. 6 VA/2.5 W Residual Ripple DC 10 % Voltage and Current at the N/C: 24 VDC, 20 mA Input Circuits 1/2 N/O: 24 VDC, 10 mA Switching Capability in accordance with EN 60947-4-1, 10/91 AC1: 240 V/6 A/1500 VA
EN 60947-5-1, 111/97 AC15: 230 V/2.5 A; DC13: 24 V/1.5 A (DC13: 6 cycles/min.) Output Contacts 3 safety contacts (N/O),
Contact Fuse Protection 6 A quick or 4 A slow (EN 60947-5-1, 11/97)
Times
Repsonse time (delay-on de-energisation) N/O: approx.15 ms, N/C: approx. 30 ms Recovery Time Min. 250 ms Simultaneity channel 1/2 < 0.5 s
Environmental Data
Storage Temperature -25 ... +85 °C
Mechanical Data
Maximum Cross Section of 2 x 1.5 mm External Conductors Single-core or multi-core with
Dimensions (H x W x D) 87 x 45 x 121 mm Weight AC: 390 g, DC: 290 g
AC: 24, 42, 48, 110, 115, 120, 200, 230, 240 V DC: 24 V
DC1: 24 V/5 A/120 W
1 auxiliary contact (N/C)
2
crimp connectors
3
P2HZ X1
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-078-11/01 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Description
45 mm, P-93 housing, DIN-Rail mounting
Positive-guided relay outputs: – 3 safety contacts (N/O) – 1 auxiliary contact (N/C)
Increase in the number of safety contacts available by connecting extpander modules
LEDs for power, channel 1 and channel 2
Function Description
The two-hand relay is a safety device to ensure that operators keep their hands away from the danger zone. The relay is suitable for use with mechanical and hydraulic presses, or in safety circuits. A cycle can only be initiated by pressing the two pushbuttons simultaneously (within 0.5 s). A cycle
is interrupted by releasing one or both buttons to stop the output. The output signal can only be reinitiated after both inputs have been released and the pushbuttons are operated again.
Two-hand Relays
EN 574, Type IIIC
P2HZ X1
3
Internal Wiring Diagram
A2
A1
T1
+
~
=
Y31
Y35
Y32 Y30
Function Diagram
1
U
B
0
1
Button 1
0
1011
Button 2
K2
K1
Input circuit
S12
S13
Feedback control loop
S11
Control logic
Channel 1
Increase in safety contacts The number of output contacts can
Safety
Input circuit
S22
S23
Y2
Y1
S21
Channel 2
K1
13
K2
14
contacts
23
24
33
34
Auxiliary contact
41
42
be increased by using expander modules or relays/contactors with positive-guided contacts.
L1
F1
K5 K6
X1 X2
N
23
24
K5 K6
F2
43
44
– Driving a load
L+
F2
F1
13
23
Feedback
1
control loop
0
1
1
Output
0
t0t
t
1
2
No significance
Feedback control loop open: 0 Feedback control loop closed: 1
t0:UB must be applied at least 200 ms
before button 1 is pressed
Connection Example
L1
S1 S2
F3
S11
S12 S13 S21 S22
A1
13 23 33 Y1
14
24 34 41 42
Y30
Y31 Y32 Y35
N
S23
Y2
A2
t
3
t
1
t1: Simultaneity < 0.5 s t2: Operating cycle is ended via button
1 or 2
t3: Y1-Y2 must be closed at least 200 ms
before a button is operated
– Key
S1/S2: Two-hand pushbuttons
14
24
L-
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-078-11/01 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de