Two-hand Relays
EN 574, Type IIIC
P2HZ X1
Two-hand relay in accordance with
VDE 0113-1, 11/98, EN 60204-1,
12/97 and IEC 204-1, 11/98.
Features
● 2 semiconductor outputs
(Fault, CH.1/CH. 2)
● Conforms to type IIIC in
accordance with EN 574
and category 4 in accordance
with EN 954-1
Approvals
Technical Details P2HZ X1
Electrical Data
Supply Voltage
Tolerance 85 ... 110 %
Power Consumption Approx. 6 VA/2.5 W
Residual Ripple DC 10 %
Voltage and Current at the N/C: 24 VDC, 20 mA
Input Circuits 1/2 N/O: 24 VDC, 10 mA
Switching Capability in accordance with
EN 60947-4-1, 10/91 AC1: 240 V/6 A/1500 VA
EN 60947-5-1, 111/97 AC15: 230 V/2.5 A; DC13: 24 V/1.5 A
(DC13: 6 cycles/min.)
Output Contacts 3 safety contacts (N/O),
Contact Fuse Protection 6 A quick or 4 A slow
(EN 60947-5-1, 11/97)
Times
Repsonse time (delay-on de-energisation) N/O: approx.15 ms, N/C: approx. 30 ms
Recovery Time Min. 250 ms
Simultaneity channel 1/2 < 0.5 s
Environmental Data
Storage Temperature -25 ... +85 °C
Mechanical Data
Maximum Cross Section of 2 x 1.5 mm
External Conductors Single-core or multi-core with
Dimensions (H x W x D) 87 x 45 x 121 mm
Weight AC: 390 g, DC: 290 g
AC: 24, 42, 48, 110, 115, 120, 200, 230,
240 V
DC: 24 V
DC1: 24 V/5 A/120 W
1 auxiliary contact (N/C)
2
crimp connectors
3
P2HZ X1
●
●
●
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-078-11/01
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Description
● 45 mm, P-93 housing, DIN-Rail
mounting
● Positive-guided relay outputs:
– 3 safety contacts (N/O)
– 1 auxiliary contact (N/C)
● Increase in the number of
safety contacts available by
connecting extpander modules
● LEDs for power, channel 1 and
channel 2
Function Description
The two-hand relay is a safety device
to ensure that operators keep their
hands away from the danger zone.
The relay is suitable for use with
mechanical and hydraulic presses, or
in safety circuits.
A cycle can only be initiated by
pressing the two pushbuttons
simultaneously (within 0.5 s). A cycle
is interrupted by releasing one or
both buttons to stop the output.
The output signal can only be
reinitiated after both inputs have
been released and the pushbuttons
are operated again.
Two-hand Relays
EN 574, Type IIIC
P2HZ X1
3
Internal Wiring Diagram
A2
A1
T1
+
~
=
Y31
Y35
Y32
Y30
Function Diagram
1
U
B
0
1
Button 1
0
1011
Button 2
K2
K1
Input circuit
S12
S13
Feedback
control loop
S11
Control logic
Channel 1
● Increase in safety contacts
The number of output contacts can
Safety
Input circuit
S22
S23
Y2
Y1
S21
Channel 2
K1
13
K2
14
contacts
23
24
33
34
Auxiliary
contact
41
42
be increased by using expander
modules or relays/contactors with
positive-guided contacts.
L1
F1
K5 K6
X1 X2
N
23
24
K5 K6
F2
43
44
– Driving a load
L+
F2
F1
13
23
Feedback
1
control
loop
0
1
1
Output
0
t0t
t
1
2
No significance
Feedback control loop open: 0
Feedback control loop closed: 1
t0:UB must be applied at least 200 ms
before button 1 is pressed
Connection Example
L1
S1 S2
F3
S11
S12 S13 S21 S22
A1
13 23 33 Y1
14
24 34 41 42
Y30
Y31 Y32 Y35
N
S23
Y2
A2
t
3
t
1
t1: Simultaneity < 0.5 s
t2: Operating cycle is ended via button
1 or 2
t3: Y1-Y2 must be closed at least 200 ms
before a button is operated
– Key
S1/S2: Two-hand pushbuttons
14
24
L-
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-078-11/01
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de