Phottix INDRA Instruction Manual

1
INSTRUCTION MANUAL
En
INSTRUCTION MANUAL ------------------------- 2
说明书 ---------------------------------------------- 20
說明書 -----------------------------------------------36
Cn
Simp
Cn
Trad
Phottix Indra Battery Pack
2
Thank you for purchasing a Phottix product:
Note: Before using the Phottix Indra Battery Pack, please read this instruction manual carefully.
The Phottix Indra Battery Pack is a professional power supply for flashes with an external power port. With the Phottix Indra Battery Pack ash recycling times can be reduced to 1/4th of the time needed when using internal batteries, allowing you to shoot faster and miss fewer shots. When used, for example, with the Phottix Mitros+ TTL Transceiver Flash for Canon, the Phottix Indra Battery Pack can provide eight times as many ashes compared with the internal batteries. Reliable and durable, it is equipped with both overcharge and over-discharge protection systems to help extend the battery life. With the removable backup Li-ion cell, it promises great power performance.
For your safety
The AC Charging Unit and the Indra Battery Pack contains high voltage electronic parts. Do not disassemble or attempt to repair them. Keep this product out of the reach of children.
Do not touch the metal parts of the AC charging unit.
The Li-ion cell has a lifespan based on use. When the Indra Li-ion cell is no longer functional contact local authorities for proper disposal and replace the cell with a new one.
Never use this product near combustible gases, solvents or in an environment with a high electrical charge.
Make sure all plugs and cables are well connected during charging and use.
3
INSTRUCTION MANUAL
En
Faulty electrical contacts or short circuits may cause the Battery Pack to overheat. If this happens turn o the Battery Pack immediately and all disconnect devices.
Do not expose the Li-ion cell to high
temperatures over 45°C (e.g. left in a car trunk).
This product is not waterproof. Keep away
from rain, snow and high humidity conditions.
Do not clean either the Battery Pack body or any accessories with organic solvent or alcohol­based liquid.
Use only a Phottix Indra original Li-ion cell. Third party cells could cause damage to the unit.
The fast recycle times made possible when using the Phottix Indra Battery Pack could
damage your flash if continuously shooting at high power settings. Some flashes have overheating protection settings, some do not. Consult your ash manual and use cautiously.
If the Battery Pack voltage is very low there will be no output. Charge the Battery Pack before use.
When powering ashes or other products, it is normal for the Phottix Indra Battery Pack to become hot.
Do not touch the metal contacts on the Battery Pack or the cell with metal objects.
Charge the Battery Pack regularly to extend the battery life time.
Use caution in touching the casing after use. It may still be hot and could cause burns.
4
Consult local authorities on the proper disposal
or recycling of a Phottix Indra Battery Pack.
5
INSTRUCTION MANUAL
En
Parts
Battery Pack
1. Output Port 1
2. Output Port 2
3. USB Output Port
4. Output Toggle Switch
5. Output Indicator
6. Battery Level Indicators
7. Cable Locking Lever
8. Carrying Strap Slot
9. Body
10. Locking Latch Release Button
11. Li-ion Cell
6
Body
1. Negative Electrical Contacts
2. Positive Electrical Contacts
3. Locking Slot
Li-ion Cell
1. Positive Electrical Contacts Slot
2. Charging Port
3. Negative Electrical Contacts Slot
4. Mounting Slot
7
INSTRUCTION MANUAL
En
AC Charging Unit
1. Charging Unit
2. Charing Indicator
3. Output Charging Connector
Please note:
When using only one output port, please cover the
unused output port to avoid possible short circuits.
Install AA batteries when using hot shoe ashes with
the Phottix Indra Battery Pack.
Only use compatible flash power cords, non-
compatible flash power cords may cause damage to the ash.
When powering two ashes at the same time, more
power is used. Recycling time with two flashes is slower than with one ash.
When the Phottix Indra Battery Pack over heat sit will
no longer supply power to external ashes. The output indicator(s) on the Battery Pack will start flickering. This overheating protection will last 4-5 minutes and after this time the Indra Battery Pack can be used again. After the overheating protection is triggered
8
button downwards with one hand.
2. With the other hand hold the Body of the Phottix Indra Battery Pack and pull it to the left. This will separate the two parts. (See picture 1)
picture 1
To assemble
1. Hold the Li-ion cell in one hand and use the other hand
any ashes attached to the Indra Battery Pack will switch to internal batteries power. (See you flash manual for more details).Recycling time will become slower.
Note: when powering two studio lights, firing at 1/1 output levels and at a speed of once per 5s, at the same time, after about 120 shots, the Phottix Indra Battery Pack will trigger the overheating protection.
Turn off the Battery Pack when not in use. If left on
battery power will continue to drain even if no devices are attached. Over-discharge will cause damage to the unit.
Assembling and disassembling the Phottix Indra Battery Pack
To disassemble
1. Hold the Li-ion cell and slide the locking latch release
9
INSTRUCTION MANUAL
En
to hold the body of the Battery Pack.
2. Push it to the right until the lock engages with a click, this ensures it is locked. (See picture 2)
Note: when the Li-ion cell is properly assembled onto the body of the Battery Pack, the Output Indicator (orange), the Battery Level Indicators (green) and the USB indicator (red) will all light up and ash 3 times.
picture 2
To charge the battery pack
Use an original Phottix AC Charging Unit only.
1. Insert the output charging connector of the AC Charging Unit into the charging port on the Battery Pack.
2. Connect the AC power cord of the AC Charging Unit to the mains power supply. (See picture 3)
picture 3
10
When charging, the charging indicator on the AC Charging Unit will light red. It will turn green when fully charged. (See picture 4)
Picture 4
To connect the ashes
A compatible Phottix flash power cord is required for use with Canon, Nikon, Sony, and Phottix Mitros series ashes as well as the Phottix Indra 500 TTL Studio Light. The Phottix Indra Battery Pack can power a single ash or two ashes at the same time.
Please turn o all switches on the Phottix Indra Battery Pack and the ashes before connecting the ash power cords.
To power a single ash
1. Align the plug of the ash power cord with the Battery Pack output port. Make sure to use a compatible flash power cord.
2. Slide the cable locking lever up and insert the cord into the port until the lock engages with a click. (See picture 5)
11
INSTRUCTION MANUAL
En
Picture 5
3. Insert the other end of the cord into the external power port on the ash. (See picture 6 and 7)
Picture 6 Picture 7
To power two ashes at the same time
The Phottix Indra Battery Pack can power two ashes at the same time. A compatible flash or studio light power cord is required.
1. Insert the ash power cords into the output ports on the Phottix Indra Battery Pack.
12
2. Insert the other end of the cords into the external power ports on the ashes. (See picture 8)
Picture 8
To disconnect the ashes
1. Before disconnecting the flash, move the output
toggle switch to the “OFF” position. The output indicator will go out after 2 seconds.
2. Slide the cable locking lever to the “UNLOCK” position and pull the cable out of the output port. (See picture 9)
Picture 9
Using the Battery Pack
1. Install batteries in the flash properly (See picture 10)
13
INSTRUCTION MANUAL
En
and make sure the battery power is strong enough to power on the flash. If the power of the internal batteries is not sufficient, the Indra Battery Pack cannot power the ash.
Picture 10
2. Make sure all the power cords are well connected to the Battery Pack. When the output toggle switch is turned on, the Battery level indicators will light green. If no device has been detected, both output ports will
cut o automatically after 10 seconds, and the Battery indicators will go out. If a device has been detected by either of the output port, the corresponding output will start powering, and the corresponding Output indicator (orange) and the Battery level indicators will light up simultaneously. (See picture 11)
Picture 11
Note: If the output toggle switch is not turned on, there will be no output from both output ports. However, there will be output from the USB output port if a device has been connected to it.
14
3. There are 2 power levels for option on the Indra Battery Pack, “High Speed” and “Standard”. If “High Speed” is selected, the Indra Battery Pack will charge the ash(es) very fast. To extend usage time and reduce load intensity of the Battery Pack, please use Standard output power level unless faster recharge times are required. (See picture 11)
USB Powering
The 5V output USB port can be used to charge mobile devices, such as tablets, smartphones and media players.
If no device is connected to the USB port, there will be no output from the USB output. If an external mobile device is connected and charging, the USB indicator will light red. When fully charged, the USB indicator will turn o. (See picture 12)
Picture 12
When using the Indra Battery Pack, the battery level indicators on the Battery Pack will light up to display the power capacity left in the Li-ion cell. (From left to right, see picture 13)
4 LED indicators light up ≥80%
15
INSTRUCTION MANUAL
En
3 LED indicators light up ≥60%
2 LED indicators light up ≥40%
1 LED indicators light up ≥20%
1 LED indicator ashes ≤20%
When the battery capacity is less than 10%, the Battery Pack will stop powering and need to be charged.
Picture 13
Battery capacity indication (part):
4 LED lights (≥80%)
2 LED lights (≥40%)
1 LED lights (≥20%)
16
Technical Specication
Cell type
Cycle life
Charging time
Recycle time (at 1/1 ash power levels; the Studio Light Flash-ready indi­cator lights red)
Li-Ion polymer batteries
10000mAh
H mode
S mode
10000mAh: approx. 5.5 hrs 5000mAh: approx. 2.5 hrs
Phottix Indra 500 TTL Studio Light Single/Two ashes: 1s/2.3s
Phottix Indra 500 TTL Studio Light Single/Two ashes: 1.4s/5.4s
Phottix Mitros/Mitros+ Flash Single ash: 0.26s
Phottix Mitros/Mitros+ Flash Single ash: 0.38s
3.7V/10000mAh*4=14.8V/10000mAh, approx. 400-cyclerecharge
3.7V/5000mAh*4=14.8V/5000mAh, approx. 400-cyclerecharge
Loading...