PRODUCT INFORMATION

Features

-Colour white/grey

-Careeza soleplate

-Tank capacity (350 ml)

-Steam rate (40 g/min)

-Shot of steam (80 g)

-Vertical steam

-Permanent Anti-Calc

-Automatic shut off

-Soft touch hand grip

-Protective storage cover

-Integrated cord winder with clip

-Extra long cord : 3 m.

Safety Information

-This product meets the requirements regarding interference suppression on radio and TV.

-After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as officially laid down at this moment.

TECHNICAL INFORMATION

Voltage

: 120 V, 220 - 240 V

Frequency

:

50 - 60 Hz

Power consumption

:

1450 W, 2200 W

Water advice

Suitable for tap water use. However if the tap water in your area is very hard, we advise you to mix it with an equal portion of distilled water or to use distilled water only.

Cleaning of the Iron

Use only the Calc clean button for cleaning of the Iron. Never use vinegar or other descaling agents.

Soleplate

Careeza is a multi layer chemical substance that gives an excellent gliding over various fabrics and better care for the garments.

Auto shut-off (ASO)

A relay in the electronic module interrupts the power to the heating element when the iron has been motionless.

-for 30 secs in the horizontal position.

-for 8 minutes in the vertical position. The red “Auto-off” pilot light starts blinking.

When the iron is moved again, it is automatically switched ‘ON’ again.

Vertical Steam

When the iron is kept in a vertical position, the shot of steam (S.O.S) button can be used to iron hanging fabrics such as curtains.

Anti drip

Water is only released to through the tank valve into the steam chamber if the soleplate temperature is high enough to evaporate all water. If the temperature is too low, the tank valve is closed by means of a bi-metal disc.

Protective storage cover

The cover protects the soleplate from accidental damage.

Caution : Do not use the cover while the iron is heating up or with the plug in the mains.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

03/06

Philips GC4040 Service Manual

DISASSEMBLY ADVICE

DIAL 1

RATTLE SPRING 2

BACKPLATE 102, 103

CORDSET 4

SWIVEL HOLDER 101

SWIVEL 104

Remove Screw A

Remove Screws B1, B2

FILLING DOOR 6

INLAY 7

OPERATION KNOBS 8 ASO UNIT 9 (PCB)

Remove Screw A

Remove Backplate 3, 26

SLIDE UNIT 10

NEEDLE SET 11

TANK SEAL 12

HANDLE 13

SELF CLEAN BUTTONS 14 SPRAY NOZZLE ASSY 15 PUMP ASSY 16

Remove

Screw A

Remove

Backplate 102, 103

Remove

Inlay 106

Remove Operation knobs 107, 108 Remove Screws C1, C2

Remove Slide Unit 114, 115 Remove Needle set 116, 117, 118 Remove Screws D1, D2

THERMOSTAT BUSH 17

 

WATER TANK 18

Remove

Screw A

Remove

Backplate 102, 103

Remove

Inlay 7

Remove Operation knobs 107, 108

Remove

Screws D1, D2

Remove

Handle 13

Remove

Screws E1, E2

Remove

Water tank 18

Remove

Screw F

GC4040

SOLEPLATE COVER 19

ISOLATION PLUG 20

SOS SEAL 21

DOSING SEAL 22

SOLEPLATE ASSY 23

Remove

Screw A

Remove

Backplate 102, 103

Remove

Inlay 7

Remove Operation knobs 107, 108

Remove

Screws D1, D2

Remove

Handle 13

Remove

Screws E1, E2

Remove

Water tank 18

Remove

Screw F

Remove

Heat shield

Remove

Screws G1, G2

Remove

Soleplate cover 19

REPAIR INSTRUCTIONS

-Due to high voltage of the iron, ONLY the specified cordsets must be used.

-For standardisation reasons :

Dial

: With English / Spanish text only.

Rattle spring : 5 pcs will be supplied when ordered.

Type plate : No information about the typenumber and voltage have been stamped onto the typeplate. When replacing the typeplate, engrave at least typenumber onto the typeplate with a sharp object.

-Parts with numbers from 100 and higher, cannot be ordered separately

-Thermostat 119, fitted to the soleplate 23 has already been adjusted by the supplier and secured by glue.

To avoid mal-function of the iron, NEVER re-adjust the thermostat.

-The thermostat 119 can only be ordered together with the soleplate assembly 23.

OPTIONAL (accessories)

- No specific issues

2-4