PRODUCT SPECIFICATION
CM9760-SAT Matrix Switcher
CM9740/CM9760 SATELLITE VIDEO MATRIX SWITCHER, 16 X 4
control site
Product Features
• 16-Input Satellite Switcher
• 4 Outputs; Programmable for Local Monitoring or Remote Tie Lines
• 16 Alarm Inputs for Both Local and Remote Alarm Handling
• Economical Solution for Remote Switching
• Compatible with Both CM9740 and CM9760 Systems (Requires
Version 7.80.003 Software or Later)
• On-screen Programming via Local KBD300 Keyboard or Remote
CM9760-KBD Keyboard
The CM9760-SAT allows you to distribute switching capability
around a facility, reducing the number of coaxial cable runs to the
9740/9760 matrix and allowing local monitoring at the satellite
switch locations. Up to 16 cameras can be connected to one
CM9760-SAT. Four outputs are provided. At least one must be used
for video feed to a camera input on the CM9740/CM9760 matrix
bay. The others can be used for either local monitors or additional
video feeds. This allows 16 cameras to share
• one video feed, one camera at a time, and three local monitors; or
• two video feeds, two cameras at a time, and two local monitors; or
• three video feeds, three cameras at a time, and one local monitor
(see illustration below); or
• four video feeds, four cameras at a time, and no local monitor.
CM9760-SAT (FRONT)
CM9760-SAT (BACK)
Cameras can be selected for viewing and controlled from either the
main keyboard at the CM9740/CM9760 matrix bay or from a local
keyboard at the satellite unit. In addition to camera selection and
control, the satellite provides 16 alarm inputs that can transport
alarms to the main control center.
The KBD200A and KBD300A keyboards can be used with the
CM9760-SAT.
REMOTE SITE
1-16 CAMERAS
KBD300A
LOCAL MONITOR
DataFAX
SPEC: 21510
MANUAL: Not Available through DataFAX
®
C1510 / REVISED 10-02
CM9760SAT
RS-422
DATA
LINE
VIDEO FEEDS
LOCAL SITE
CM9740/CM9760
CPU
MATRIX
BAY
CM9760-KBD
International Organization
for Standardization;
Registered ISO 9001
TECHNICAL SPECIFICATIONS
MODELS
CM9760-SAT Satellite video matrix switcher, 16 inputs by
4 outputs, NTSC
CM9760-SAT-X Satellite video matrix switcher, 16 inputs by
4 outputs, PAL
Note: Requires 9740/9760 System Software Version 7.80.003 or later
RELATED PRODUCTS
KBD200A Desktop keyboard, multi-speed PTZ.
KBD300A Desktop keyboard, variable-speed PTZ.
KBDKIT Remote keyboard wiring kit. Required if
connecting multiple keyboards to the remote
keyboard port. Includes RJ-45 wall block and
120 VAC to 12 VAC transformer.
(One kit required for each keyboard.)
KBDKIT-X Same as KBDKIT except includes 230 VAC to
12 VAC transformer.
SWITCHING
Switching Duration Programmable; user defined between 1 and
99 seconds
Programmable Number
of Steps per Sequence Sixteen
Maximum Number of
Sequences Four
VIDEO
Number of Inputs Sixteen
75-ohm unbalanced terminating or looping;
jumper selectable
Number of Outputs Four (maximum)
75-ohm unbalanced
Level 1 Vp-p
Connector Type Panel-mount BNC
Video Fail Detection
Type Vertical sync detector
Action Switch to back-up sync generator
Connector Type Panel-mount BNC
Bandwidth 17 Mhz
Frequency Response Flat to 8 Mhz, ±1.0 dB to 15 Mhz
Gain Unity (±1 dB)
Differential Gain 2% typical
Differential Phase 0.2 degree typical
Tilt 0.5% typical
Signal-to-Noise -55 dB (peak-to-peak vs. RMS noise)
DC Output Zero volts
Cross Talk -50 dB typical at 3.58 Mhz
CHARACTER GENERATOR
Display White with black border
Program Menus Raster background with white characters
SAT COM CONNECTIONS
Connector Type One 12-pin connector with mating plug
(supplied)
Data Ports
COM 1
(Receiver Control) RS-422, P protocol; program selectable baud
rate
COM 2
(Comm Interface) RS-422, 9600 baud, odd parity, one stop bit
KEYBOARD INTERFACE
Protocol Keyboard
Number of Ports Two
One Local RJ-45, 8-pin modular (powered)
One Remote 6-pin header with mating plug
(KBDKIT required)
Number of
Independent Keyboards Four (combined total)
Data Rate 9600 baud
ALARM INTERFACE INPUTS
Number of Inputs Sixteen
Connector Type 12-pin screw terminal
Sensing Programmable, N.O./N.C.
AUXILIARY OUTPUTS
Number of Outputs Three
Connector Type 12-pin screw terminal
Contact Configuration
F1 Form C, 0.5 amp at 125 VAC maximum
F2 and F3 Open collector, 32 VDC, 25 mA maximum
POWER SUPPLY
Input Voltage
CM9760-SAT 120 VAC, 50/60 Hz
CM9760-SAT-X 230 VAC, 50 Hz
Power Consumption 10 watts
Ambient Operating
Temperature 20° to 120°F (-7° to 49°C)
Humidity 10% to 90%, non-condensing
PHYSICAL SPECIFICATIONS
Dimensions 3.5" H x 19.0" W x 10.5" D (2 RUs)
(8.89 x 48.26 x 26.67 cm)
Mounting Factory configured for EIA rack mount; rack
ears can be removed for wall mount or
free-standing applications.
Weight
CM9760-SAT 10.15 lb (4.61 kg)
CM9760-SAT-X 10.06 lb (4.56 kg)
Shipping Weight 11 lb (4.99 kg)
Pelco Worldwide Headquarters:
3500 Pelco Way, Clovis, California 93612-5699 USA
USA & Canada Tel: (800) 289-9100 • FAX (800) 289-9150 • DataFAX (800) 289-9108
International Tel: (559) 292-1981 • FAX (559) 348-1120 • DataFAX (559) 292-0435
®
www.pelco.com
CERTIFICATIONS
• CE, Class B (CM9760-SAT-X)
• UL Listed (CM9760-SAT)
• UL Listed to Canadian safety standards (CM9760-SAT)
• FCC, Class A (CM9760-SAT)
Specifications subject to change without notice.