Pelco CM9760-SAT Specsheet

CM9760-SAT Matrix Switcher
CM9740/CM9760 SATELLITE VIDEO MATRIX SWITCHER, 16 X 4
control site
Product Features
16-Input Satellite Switcher
4 Outputs; Programmable for Local Monitoring or Remote Tie Lines
16 Alarm Inputs for Both Local and Remote Alarm Handling
Economical Solution for Remote Switching
Compatible with Both CM9740 and CM9760 Systems (Requires
Version 7.80.003 Software or Later)
On-screen Programming via Local KBD300 Keyboard or Remote
CM9760-KBD Keyboard
The CM9760-SAT allows you to distribute switching capability around a facility, reducing the number of coaxial cable runs to the 9740/9760 matrix and allowing local monitoring at the satellite switch locations. Up to 16 cameras can be connected to one CM9760-SAT. Four outputs are provided. At least one must be used for video feed to a camera input on the CM9740/CM9760 matrix bay. The others can be used for either local monitors or additional video feeds. This allows 16 cameras to share
• one video feed, one camera at a time, and three local monitors; or
• two video feeds, two cameras at a time, and two local monitors; or
• three video feeds, three cameras at a time, and one local monitor (see illustration below); or
• four video feeds, four cameras at a time, and no local monitor.
CM9760-SAT (FRONT)
CM9760-SAT (BACK)
Cameras can be selected for viewing and controlled from either the main keyboard at the CM9740/CM9760 matrix bay or from a local keyboard at the satellite unit. In addition to camera selection and control, the satellite provides 16 alarm inputs that can transport alarms to the main control center.
The KBD200A and KBD300A keyboards can be used with the CM9760-SAT.
REMOTE SITE
1-16 CAMERAS
KBD300A
LOCAL MONITOR
DataFAX
SPEC: 21510 MANUAL: Not Available through DataFAX
®
C1510 / REVISED 10-02
CM9760SAT
RS-422 DATA LINE
VIDEO FEEDS
LOCAL SITE
CM9740/CM9760
CPU
MATRIX BAY
CM9760-KBD
International Organization
for Standardization;
Registered ISO 9001
TECHNICAL SPECIFICATIONS
MODELS
CM9760-SAT Satellite video matrix switcher, 16 inputs by
4 outputs, NTSC
CM9760-SAT-X Satellite video matrix switcher, 16 inputs by
4 outputs, PAL
Note: Requires 9740/9760 System Software Version 7.80.003 or later
RELATED PRODUCTS
KBD200A Desktop keyboard, multi-speed PTZ. KBD300A Desktop keyboard, variable-speed PTZ. KBDKIT Remote keyboard wiring kit. Required if
connecting multiple keyboards to the remote keyboard port. Includes RJ-45 wall block and 120 VAC to 12 VAC transformer. (One kit required for each keyboard.)
KBDKIT-X Same as KBDKIT except includes 230 VAC to
12 VAC transformer.
SWITCHING
Switching Duration Programmable; user defined between 1 and
99 seconds Programmable Number of Steps per Sequence Sixteen Maximum Number of Sequences Four
VIDEO
Number of Inputs Sixteen
75-ohm unbalanced terminating or looping;
jumper selectable Number of Outputs Four (maximum)
75-ohm unbalanced Level 1 Vp-p Connector Type Panel-mount BNC Video Fail Detection
Type Vertical sync detector Action Switch to back-up sync generator
Connector Type Panel-mount BNC Bandwidth 17 Mhz Frequency Response Flat to 8 Mhz, ±1.0 dB to 15 Mhz Gain Unity (±1 dB) Differential Gain 2% typical Differential Phase 0.2 degree typical Tilt 0.5% typical Signal-to-Noise -55 dB (peak-to-peak vs. RMS noise) DC Output Zero volts Cross Talk -50 dB typical at 3.58 Mhz
CHARACTER GENERATOR
Display White with black border Program Menus Raster background with white characters
SAT COM CONNECTIONS
Connector Type One 12-pin connector with mating plug
(supplied)
Data Ports
COM 1 (Receiver Control) RS-422, P protocol; program selectable baud
rate COM 2 (Comm Interface) RS-422, 9600 baud, odd parity, one stop bit
KEYBOARD INTERFACE
Protocol Keyboard Number of Ports Two
One Local RJ-45, 8-pin modular (powered) One Remote 6-pin header with mating plug
(KBDKIT required)
Number of Independent Keyboards Four (combined total) Data Rate 9600 baud
ALARM INTERFACE INPUTS
Number of Inputs Sixteen Connector Type 12-pin screw terminal Sensing Programmable, N.O./N.C.
AUXILIARY OUTPUTS
Number of Outputs Three Connector Type 12-pin screw terminal Contact Configuration
F1 Form C, 0.5 amp at 125 VAC maximum F2 and F3 Open collector, 32 VDC, 25 mA maximum
POWER SUPPLY
Input Voltage
CM9760-SAT 120 VAC, 50/60 Hz CM9760-SAT-X 230 VAC, 50 Hz
Power Consumption 10 watts Ambient Operating Temperature 20° to 120°F (-7° to 49°C) Humidity 10% to 90%, non-condensing
PHYSICAL SPECIFICATIONS
Dimensions 3.5" H x 19.0" W x 10.5" D (2 RUs)
(8.89 x 48.26 x 26.67 cm)
Mounting Factory configured for EIA rack mount; rack
ears can be removed for wall mount or
free-standing applications.
Weight
CM9760-SAT 10.15 lb (4.61 kg) CM9760-SAT-X 10.06 lb (4.56 kg)
Shipping Weight 11 lb (4.99 kg)
Pelco Worldwide Headquarters:
3500 Pelco Way, Clovis, California 93612-5699 USA
USA & Canada Tel: (800) 289-9100 • FAX (800) 289-9150 • DataFAX (800) 289-9108 International Tel: (559) 292-1981 • FAX (559) 348-1120 • DataFAX (559) 292-0435
®
www.pelco.com
CERTIFICATIONS
• CE, Class B (CM9760-SAT-X)
• UL Listed (CM9760-SAT)
• UL Listed to Canadian safety standards (CM9760-SAT)
• FCC, Class A (CM9760-SAT)
Specifications subject to change without notice.
©Copyright 2002, Pelco. All rights reserved.