Pelco CM9700-SER-32 User Manual

CM9700-SER-32 Port Expander
INSTALLATION/OPERATION
C579M-A (5/05)

Contents

Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4 Sercom Cards, 1 Rocket Port Card (64 Total Ports) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4 Sercom Cards, 2 Rocket Port Cards, Com 2 Unavailable (96 Total Ports) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
3 Sercom Cards, 2 Rocket Port Cards, Com 2 Available (88 Total Ports) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Sercom Cards, 3 Rocket Port Cards, Com 2 Unavailable (120 Total Ports) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

List of Illustrations

1 CM9700-SER-32 Assembly Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2 Removing the CC1 Top Cover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3 CC1 Internal Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Rocket Card to Expansion Port Control Association. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5 Sercom Card Mounting Plate Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
6 Sercom/PCI Card Configuration for 88 Ports, Com 2 Available . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
7 CM9700-ADP-120 Adapter Plate Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
8 Sercom/PCI Card Configuration for 120 Ports, Com 2 Unavailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 C579M-A (5/05)

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

Installation

The CM9700-SER-32 port expander assembly increases by 32 the number of available Sercom (serial communication) ports in a node-based CM9700-CC1 via the installation of an RP (rocket port) PCI expansion card. A maximum of 120 total ports can be achieved by using three CM9700-SER-32 assemblies in conjunction with the Sercom cards in the CC1. Refer to Figure 1 for assembly detail.
Figure 1. CM9700-SER-32 Assembly Detail

4 SERCOM CARDS, 1 ROCKET PORT CARD (64 TOTAL PORTS)

1. Turn off all power to the CC1. Disconnect and label all attached cabling.
2. Install the RP card into the CC1. Refer to Figure 2 and Figure 3 and do the following:
a. Remove the top cover mounting screws.
b. From the rear, tilt the top cover up at a slight angle, and then pull backwards away from the front edge to remove the cover from the
CC1 chassis.
NOTE: If the VGA card is present in PCI slot 2, remove the retaining screw and gently pull the card up. Reinstall the card into PCI slot 4 (follow
steps c and d, applying them to the VGA card and PCI slot 4).
c. Remove the retaining screw and slot cover for PCI slot 2. Slide the cover out.
d. Install the RP card into PCI slot 2. Carefully align the gold-fingered edge connector of the RP card with the PCI slot. Gently but firmly
press the RP card down until fully seated into the PCI slot. Reinstall the retaining screw to secure the RP card into place.
WARNINGS:
Software version 9.03.007 or higher must be installed in the CC1 to enable port expansion ability. If running a previous version, contact Pelco for software upgrade kit options and availability.
Failure to turn off the CC1 power could result in serious damage to the equipment.
Electrostatic discharge (ESD) precautions must be observed when performing the procedures described in this manual. Always wear a gounding strap connected to an approved grounding source when working on or around exposed electronic components.
CONNECTING DATA CABLE (2) ONE SET OF CONNECTING DATA CABLES IS PROVIDED. EACH CABLE IS THREE FEET LONG.
CM9700-ADP-120 ADAPTER BRACKET FOR USE WITH RP CARD IN PCI SLOT 1.
PCI EXPANSION CARD (1) (ROCKET PORT CARD)
HOST CONNECTIONS
ADAPTER DB25 TO RJ-45 (32)
RS-232/422 SWITCH (32) COMM INTERFACE FOR EACH CONNECTOR IS SET BY THIS SWITCH. UP IS RS-422; DOWN IS RS-232
2
3
2
4
2
2