SS12 THRU S100
SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
VOLTAGE - 20 to 100 Volts CURRENT - 1.0 Ampere
FEATURES |
|
||
• Plastic package has Underwriters Laboratory |
|
||
|
Flammability Classification 94V-O |
|
|
• For surface mounted applications |
SMA/DO-214AC |
||
• |
Low profile package |
||
|
|||
• Built-in strain relief |
|
||
• Metal to silicon rectifier |
|
||
|
majority carrier conduction |
|
|
• Low power loss, High efficiency |
|
||
• High current capability, low VF |
|
||
• |
High surge capacity |
|
|
• For use in low voltage high frequency inverters, |
|
||
|
free wheeling, and polarity protection applications |
|
|
• |
High temperature soldering: |
|
|
|
260 ¢J /10 seconds at terminals |
|
MECHANICAL DATA
Case: JEDEC DO-214AC molded plastic
Terminals: Solder plated, solderable per MIL-STD-750,
Method 2026
Polarity: Color bank denotes cathode
Standard packaging: 12mm tape (EIA-481)
Weight: 0.002 ounce, 0.064 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ¢J ambient temperature unless otherwise specified.
Resistive or inductive load.
SYMBOLS SS12 SS13 SS14 SS15 SS16 SS18 SS19 |
S100 |
UNITS |
Maximum Recurrent Peak Reverse Voltage |
VRRM |
20 |
30 |
40 |
50 |
60 |
80 |
90 |
100 |
Volts |
Maximum RMS Voltage |
VRMS |
14 |
21 |
28 |
35 |
42 |
56 |
64 |
71 |
Volts |
Maximum DC Blocking Voltage |
VDC |
20 |
30 |
40 |
50 |
60 |
80 |
90 |
100 |
Volts |
Maximum Average Forward Rectified Current |
I(AV) |
|
|
|
|
1.0 |
|
|
|
Amps |
at TL (See Figure 1) |
|
|
|
|
|
|
|
|
|
|
Peak Forward Surge Current 8.3ms single half sine- |
IFSM |
|
|
|
30.0 |
|
|
|
Amps |
|
wave superimposed on rated load(JEDEC method) |
|
|
|
|
|
|
|
|
|
|
Maximum Instantaneous Forward Voltage at 1.0A |
VF |
|
0.5 |
|
|
0.70 |
|
0.85 |
|
Volts |
(Note 1) |
|
|
|
|
|
|
|
|
|
|
Maximum DC Reverse Current TA=25 ¢J (Note 1) |
IR |
|
|
|
|
0.5 |
|
|
|
mA |
At Rated DC Blocking Voltage TA=100 ¢J |
|
|
|
|
20.0 |
|
|
|
|
|
Maximum Thermal Resistance (Note 2) |
R £KJL |
|
|
|
|
28 |
|
|
|
¢J /W |
|
R £KJA |
|
|
|
|
88 |
|
|
|
|
Operating Junction Temperature Range |
TJ |
|
|
|
-50 to +125 |
|
|
|
¢J |
|
Storage Temperature Range |
TSTG |
|
|
|
-50 to +150 |
|
|
|
¢J |
NOTES:
1.Pulse Test with PW=300 £g sec, 2% Duty Cycle.
2.Mounted on P.C.Board with 5.0mm2 (.013mm thick) copper pad areas.