Panasonic WJ-FS416, WJ-FS316, WJ-FS309, WJ-FS409 User Manual

Video Multiplexer WJ-FS
309
FS
O
N
P
O
W
E
R
O
O
N
P
O
W
E
R
O
Video Multiplexer WJ-FS
409
FS
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
Model No. WJ-FS309
WJ-FS316 WJ-FS409 WJ-FS416
Video Multiplexer
Operating Instructions
ENGLISH
FRANÇAIS
2
The serial number of this product may be found on the bot­tom of the unit. You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid identification in the event of theft.
Model No. Serial No.
WARNING:
To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.
The lightning flash with arrowhead sym­bol, within an equilateral triangle, is intended to alert the user to the pres­ence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilat­eral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appli­ance.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SA 1965
SA 1966
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Caution: To assure continued compliance, (example ­use only shielded interface cables when connecting to com­puter or peripheral devices). Any changes or modifications not expressly approved by the party responsible for compli­ance could void the user’s authority to operate this equip­ment.
For U.S.A
Caution:
Before attempting to connect or operate this product, please read the label on the bottom.
3

CONTENTS

PREFACE .................................................................................................................................................................................... 4
FEATURES .................................................................................................................................................................................. 4
PRECAUTIONS ........................................................................................................................................................................... 5
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ..................................................................................................... 6
Front View ............................................................................................................................................................................. 6
Rear View ............................................................................................................................................................................. 8
SETUP MENU .............................................................................................................................................................................. 9
Setup Menu ........................................................................................................................................................................ 10
Alarm Setup Menu .............................................................................................................................................................. 11
Monitor Output Setup Menu ............................................................................................................................................... 13
Record Output Setup Menu ............................................................................................................................................... 14
Sequence Setup Menu ....................................................................................................................................................... 15
System Setup Menu ........................................................................................................................................................... 17
INSTALLATIONS ......................................................................................................................................................................... 22
Mounting in the Rack .......................................................................................................................................................... 22
SYSTEM CONNECTIONS ............................................................................................................................................................ 23
Basic System Connection .................................................................................................................................................. 23
Connection with the Time Lapse VCR ................................................................................................................................ 24
Connection of the Digital Disk Recorder (Example: WJ-HD100) to a Video Multiplexer .................................................... 25
Connection with the Monitors ............................................................................................................................................. 26
Connection with the WV-CU360 System Controller ............................................................................................................ 26
ALARM/REMOTE Connector .............................................................................................................................................. 27
Connection with the Alarm Sensors ................................................................................................................................... 28
Connection with the Alarm Output ..................................................................................................................................... 28
Connection with the Remote (External) Switches ............................................................................................................... 29
OPERATING PROCEDURES ....................................................................................................................................................... 30
Monitoring the Camera Picture ........................................................................................................................................... 30
Recording on the Time Lapse VCR .................................................................................................................................... 34
Monitoring the Playback Picture ......................................................................................................................................... 34
ALARM CONTROL FUNCTION ................................................................................................................................................... 37
Alarm Input ......................................................................................................................................................................... 37
Alarm Operation ................................................................................................................................................................. 37
Alarm Reset ........................................................................................................................................................................ 38
OTHER FUNCTIONS ................................................................................................................................................................... 39
Camera Switching Pulse Loss Display ............................................................................................................................... 39
ALL RESET .................................................................................................................................................................................. 39
OPERATING CONTROL OF SYSTEM UNITS (Supplementary) .................................................................................................. 39
Channel Loss Alarm ........................................................................................................................................................... 39
APPENDIX ................................................................................................................................................................................... 40
SPECIFICATIONS ........................................................................................................................................................................ 42
STANDARD ACCESSORIES ....................................................................................................................................................... 42
ENGLISH
4

PREF ACE

FEATURES

The WJ-FS309 and WJ-FS316 are Black and White Video Multiplexers, and the WJ-FS409 and WJ-FS416 are Color Video Multiplexers designed for use in surveillance security systems combined with cameras, alarm sensors, a Time Lapse VCR, two video monitors and a PC. Spot pictures and image sequences of multiple cameras can be moni­tored simultaneously on two video monitors. Multiscreen pictures and the Multiscreen sequence pictures can be dis­played on Multiscreen monitors.
Camera and playback pictures can be displayed as zoomed and stilled Spot pictures and Still Multiscreen pic­tures. Setup menus for Alarm, Monitoring, Recording and Play­back are available to match system preferences to your requirements. The WJ-FS309/FS316/FS406/FS416 and other devices com­patible with Panasonic Security Data mode the bear logo
.
• The WJ-FS309 (/FS316/FS409/FS416) can be controlled from a PC or the System Control Unit (example: WV­CU360) via an RS-485 interface.
• The pictures of any connected camera can be dis­played as a Spot picture on a full screen or Sequential screen, or as shown below on a 4-, 9- or 16-segment Multiscreen. Still and zoom modes (full screen only) are available both for live pictures and for video playback. (The 16-segment multiscreen is available with WJ­FS316 or FS416.)
• High picture quality of 720 x 480 pixels
• Multiplexed video signals with camera IDs are supplied to the Recording Output
• Versatile recording mode initiated by alarm trigger
• Playback image is displayed automatically without need to operate VCR/CAM button
• The full screen image can be zoomed in 2 times.
• Preset sequence of up to 16 (9) steps with dwell times
• Video loss detector
• On screen setup menu
• Secret view
• Versatile alarm capability
16-SEGMENT SCREEN
9-SEGMENT SCREEN
4-SEGMENT SCREEN
5
• Refer all work related to the installation of this product to qualified service personnel or system installers.
• Do not block the ventilation opening or slots on the cover.
To prevent the appliance temperature from rising, place the appliance at least 5 cm (2 inches) away from the wall.
• Do not drop metallic parts through slots.
This could permanently damage the appliance. Turn the power off immediately and refer servicing to qualified service personnel.
• Do not attempt to disassemble the appliance.
To prevent electric shock, do not remove screws or covers. There are no user-serviceable parts inside. Refer main­tenance to qualified service personnel.
• Handle the appliance with care.
Do not strike or shake, as this may damage the appli­ance.
• Do not expose the appliance to water or moisture, nor try to operate it in wet areas.
Do take immediate action if the appliance becomes wet. Turn the power off and refer servicing to qualified service personnel. Moisture can damage the appliance and also cause electric shock.
• Do not use strong or abrasive detergents when cleaning the appliance body.
Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent and wipe gently. Afterwards, wipe off the remained part of the detergent in it with a dry cloth.
• Do not operate the appliance beyond its specified temperature, humidity or power source ratings.
Do not use the appliance in an extreme environment where high temperature or high humidity exists. Use the appliance at temperatures within –10°C ­+50°C (14°F - 122°F) and a humidity below 90 %. The input power source for this appliance is 120 V AC 60 Hz.

PRECAUTIONS

6

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

Front View

<WJ-FS309/FS409>
q Power Switch (POWER ON/OFF)
This switch turns the power of the video multiplexer on or off. The LED lights up when the power is turned on.
Note: To prevent that the power of the video multiplexer
is turned off accidentally, install the supplied switch protector as shown below.
w Alarm Reset Button (ALARM RESET)
This button resets the active Alarm mode. Pressing this button turns off the Alarm indicator and replaces the “Alarm” indication on the monitor screen with the cam­era title.
<WJ-FS316/FS416>
e Alarm Indicator (ALARM)
This indicator blinks when an alarm is activated. It changes to steady light when the auto-reset time has elapsed or the alarm recovery signal is received from the VCR. To turn the indicator off, press the ALARM RESET button.
r Multiscreen Selection Button (MULTISCREEN
SELECT)
This button selects the multiscreen pattern for the moni­tor. Multiscreen is available only MULTI OUTPUT mode. Pressing this button repeatedly switches patterns as fol­lows:
Multiscreen Picture:
494 screen segments (WJ-FS309/FS409) 49164 screen segments (WJ-FS316/FS416)
Note: When ON is selected for QUAD SHIFT on the
MONITOR OUTPUT SETUP menu, the screen changes by pressing this button as follows: 4A4B9 screen segments (WJ-FS309/FS409) 4A4B4C4D→9→16 screen segments (WJ-FS316/FS416)
t
POWER
ON OFF
SWITCH
PROTECTER
ALARM
ALARM RESET
MULTI SCREEN
SELECT
SPOT MULTISCREEN
SEQ
1
2 3 4 5 6 7 8 9
t
MULTI SCREEN
SELECT
SPOT MULTISCREEN
1
SEQ
2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
POWER
ON OFF
SWITCH
PROTECTER
ALARM
ALARM RESET
SWITCH
PROTECTOR
CAMERA SELECT
CAMERA SELECT
STILL
EL-ZOOM
VCR
MENU
CAM
SET
SET
ESC
STILL
MENU
ESC
EL-ZOOM
VCR CAM
Video Multiplexer WJ-FS
Video Multiplexer WJ-FS
FS
309
FS
316
9
7
!2 Electric Zoom Button (EL-ZOOM)
This button specifies the zooming area in the multi­screen output picture. Pressing this button displays the “+” sign representing the center of the area to be enlarged. While the “+” sign is displayed for 5 seconds, move the “+” sign with the cursor buttons to the desired position and press the Increment (+) button. The desig­nated area is enlarged. To return to the normal picture press the Decrement (–) or the EL-ZOOM button.
!3 MENU/ESC Button (MENU/ESC)
Pressing this button for 2 seconds or more opens the Setup Menu of the Video Multiplexer. If pressed for less than 1 second, it functions as the Escape button and returns you to the previous menu. To close the Setup menu when the setup is completed, press the button for 2 seconds.
Notes:
• Make sure to distinguish between 1-second and 2­second operation of this button.
• Opening the Setup menu does not affect the recording signal (REC OUT) output from the rear panel.
!4 VCR/Camera Selection Button (VCR/CAM)
This button selects either VCR playback or the camera picture for display on the monitor. At the same time, it disables or enables recording on the VCR, since the connected VCR performs only playback or recording at a time. The playback picture is displayed on the moni­tor if you start playing back the VCR while the LED (Green) is on. The camera picture is displayed on the monitor while the LED is off. The camera picture is recorded on the tape if you start the VCR recording.
Notes:
• If PLAYBACK AUTO is set to ON in the setup, pressing this button is ignored, instead this button follows the VCR status automatically. VCR is select­ed while playing back, and CAMERA is selected during non-playback mode of the VCR.
• There may be a delay of a few seconds after switching this button between VCR and CAMERA when PLAYBACK AUTO is ON.
* The picture may be disturbed for a moment after
switch between VCR and camera.
• Blinking of the LED is a warning that the ID code is missing in the playback signal. This may happen when using certain VCR types. In this case, the playback picture goes straight to the monitor instead of through the Video Multiplexer. As a result, the playback picture will not be recognizable unless only a single channel is recorded throughout the tape.
The 4A screen is a compressed picture of channels 1 through 4, the 4B of channels 5 through 8, the 4C of channels 9 through 12, and the 4D of channels 13 through 16. The 9-segment screen shows the pictures of channels 1 through 9 in a 3x3 pattern.
t Spot/Multiscreen Selection Button
(SPOT/MULTISCREEN)
This button is used to select either the Spot output or Multiscreen output.
y Sequence Button (SEQ)
This button activates the sequence mode. In this mode, a series of camera pictures is displayed in succession on the monitor screen for the specified duration.
u Camera Selection Buttons (CAMERA SELECT)
These buttons select the camera for live picture or pic­ture recorded on the tape. When the VCR is in playback mode and the LED on the VCR/CAM button is on, these buttons select the specified camera picture from the tape for display on the monitor. When the LED is off, the buttons select the live picture of the specified camera.
i Cursor Buttons (C, D, A, B)
These buttons move the cursor in the SETUP MENU of the Video Multiplexer, or select an area for Electronic Zooming.
C: Downward D: Upward A: Left B: Right
o Increment/Decrement Buttons (, +)
Electronic Zooming is operated with these buttons, Zoom In with the + button and Zoom Out with the – but­ton. During the setup, these buttons are used to select parameters.
!0 Set Button (SET)
This button executes the selected parameter in the setup menu, and opens a submenu for more detailed settings. Menu items having a submenu are identified by a return symbol at the end of the line.
!1 Still Button (STILL)
This button selects either still or moving mode for dis­play on the multiscreen output monitor. Pressing a CAMERA SELECT button will display the correspond­ing picture either in still or moving mode. When a still picture is displayed, the LED lights. Pressing the button again restores the moving picture and turns off the LED. Note: Please note that the tape continues running while
the picture is stilled. You may sometimes have to rewind the tape to the desired position.
Note: Do not press more than two buttons on the front
panel simultaneously. This may cause malfunction.
8
SIGNAL
GND
ALARM/REMOTE
OUT
IN
VIDEO
16 15 14 13 12 11 10 9 8
16 15 14 13 12 11 10 9 8
7654 21
76543321
PLAY IN
REC OUT
SPOT OUT
DATA
CAMERA
SW IN
MULTI SCREEN OUT
io
u!1
!0
q Video Input Connectors (VIDEO IN)
These connectors accept a composite video signal from a camera. Note: If the input signals have a high jitter content, as in
the case of a VCR playback picture, it may not be possible to synchronize this unit.
w Video Output Connectors (VIDEO OUT)
The video signals connected to the Video Input Connectors (VIDEO IN) are looped through to these connectors with an automatic 75 termination.
e Alarm/Remote Control Connector (ALARM/
REMOTE)
This connector accepts the alarm signals from the associated alarm sensor units and the control signals from the external system.
r Playback Input Connector (PLAY IN)
The playback signal from the time lapse VCR is sup­plied to this connector.
t Record Output Connector (REC OUT)
The recording signal for the time lapse VCR is provided via this connector.
y Multiscreen Output Connector (MULTISCREEN OUT)
The video output signal for the multiscreen monitor is provided via this connector.
u Spot Output Connector (SPOT OUT)
Provides the video output signal for the spot monitor.
i Data Port (DATA)
For exchange control data with the WV-CU360 System Control Unit or a PC within a system.
o Camera Switching Input Connector
(CAMERA SW IN)
The camera switching pulse from the time lapse VCR is supplied to this connector. The camera switching interval (Sequential Dwell Time) can be synchronized with the time lapse mode set in the associated time lapse VCR.
!0 Signal Ground Terminal (SIGNAL GND)
!1 Power Cord

Rear View

<WJ-FS309/FS409>
<WJ-FS316/FS416>
987 6543 21
IN
OUT
987 6543 21
VIDEO
PLAY IN
ALARM/REMOTE
REC OUT
MULTI SCREEN OUT
i
DATA
SPOT OUT
u!1
o!0
CAMERA
SW IN
SIGNAL
GND
9

SETUP MENU

In the SETUP MENU you can set preferences for ALARM, MONITOR, REC OUT, SEQUENCE and SYSTEM to meet your requirements.

Displaying the SETUP MENU

1. Confirm that the camera and peripherals are connected correctly and securely.
2. Turn on the power switches of all system components.
3. Press the MENU/ESC button for 2 seconds or more. The SETUP MENU appears on the monitor as shown below.
WJ-FS316 SETUP
ALARM SETUP MONITOR OUTPUT SETUP REC OUTPUT SETUP SEQUENCE SETUP SYSTEM SETUP
MENU
ESC
• The following buttons are used in the SETUP MENU:
C: Moves the cursor downward. D: Moves the cursor upward. A: Moves the cursor to the left. B: Moves the cursor to the right.
– : Selects the mode or parameter. + : Selects the mode or parameter. SET: Executes the selections and displays a submenu
for an item with the ( ) mark.
• Press the MENU/ESC button to execute the currently highlighted setting and return to the previous menu in the SETUP MENU.
• To finalize the setting and return to normal viewing, press the MENU/ESC button for 2 seconds while the SETUP MENU is displayed.
Note: If alarm is activated during the setup operation,
the SETUP MENU disappears and the display returns to the normal picture. Any settings previous­ly made take effect, even if the MENU/ESC button was not pressed yet.
SET
9 10 11 12 13 14 15
The items of the WJ-FS309/FS409 SETUP MENU are the same as in the WJ-FS316/FS416 SETUP MENU.
<WJ-FS316/FS416>
1
SET
2 3 4 5 6 7
<WJ-FS309/FS409>
10

SETUP MENU

ALARM SETUP (Alarm Setup)
Page 11
MULTI OUTPUT
TITLE DISP (Camera Title Display) STILL DISP (Still Display) BORDER (Border Display) QUAD SHIFT (Quad Shift)
SECRET VIEW
BAUD RATE DATA BIT
TITLE DISP
TITLE DISPLAY (Record Title Display) REC MODE (Recording Mode)
SPOT OUTPUT
TITLE SETUP (Camera Title Setup) TITLE POSI (Camera Title Display Position) CAM SW LOSS (Camera Switching Pulse Loss Alarm) PLAYBACK AUTO (Automatic VCR Mode) PASSWORD (Password) PWR ON MULTI (Startup Multiscreen) PWR ON SPOT (Startup Spot Screen) COM. SETUP (Communication Setup)
UNIT ADDRESS CAM NUMBER (Camera Number)
WAIT TIME ALARM DATA
PARITY CHECK STOP BIT
SW INTERVAL (Field Timing) NO. OF CAMS (Camera Channel)
ENCODE
MONITOR OUTPUT SETUP (Monitor Output Setup)
REC OUTPUT SETUP (Record Output Setup)
SEQUENCE SETUP (Sequence Setup)
SYSTEM SETUP (System Setup)
Page 13
Page 17
MULTI OUTPUT
AUTO SKIP (Automatic Skip) SEQ MODE
AUTO SKIP (Automatic Skip)
SPOT OUTPUT
MLT/SPT SEQ SETUP
Page 15
DYNAMIC REC (Dynamic Recording)
ALM REC MODE (Alarm Recording Mode) AUTO RESET (Automatic Reset) ALM DISPLAY (Alarm Display) ALM OUTPUT (Alarm Output Duration) ALM BUZZER (Alarm Buzzer Duration) ALM INPUT (Alarm Input) VIDEO LOSS (Video Input Signal Loss Alarm) MLT OUT MODE (Alarm Channel Multiscreen Output Mode) SPT OUT MODE (Alarm Channel Spot Output Mode)
Page 14
Setup Menu
As shown below, the SETUP MENU has five main submenus: Alarm Setup, Monitor Output Setup, Record Output Setup, Sequence Setup and System Setup. All of these submenus are further divided into additional submenus.
11
1. Move the cursor on GROUP in the DYNAMIC REC line and press the SET button to open the GROUP SETUP menu shown above.
2. Move the cursor to the desired position by pressing the C, D, A, B buttons. Note: To turn over the page for WJ-FS316/FS416,
keep the cursor moving up or down.
3. Select the camera number by pressing the Increment (+) or Decrement (–) button.
4. Repeat steps 2 and 3 until all groupings are entered. Note: Assigning one camera channel to plural
alarm inputs is acceptable.
2. ALM REC MODE
This item lets you select the time interval (field rate) for switching the camera channel for the REC OUT signal. This setting takes effect only when an alarm is activated.
1. Move the cursor to the ALM REC MODE parameter.
2. Select a field rate or EXT by pressing the + or – button. The initial factory setting is 004.
004 - 128: REC OUT signal is switched from one cam-
era channel to another at the field rate specified here. The appropriate field rate may vary depend­ing on the VCR model. Consult the VCR specifica­tions on the field rate.
EXT: Switching of the REC OUT signal is controlled by
the camera switching signal supplied by the con­nected VCR.
1. DYNAMIC REC
This item lets you select the camera channel(s) whose pic­ture is to be recorded on the VCR when an alarm signal is received. There are priority options for recording of chan­nel(s) ranging from equal priority of all channels to exclu­sive recording of a specified channel.
1. Move the cursor to the DYNAMIC REC parameter.
2. Select OFF, ALM - PRI, ALM-ONLY or GROUP by pressing the + or – button. The initial factory setting is OFF.
OFF: The video signals are recorded from channels
number 1 to 9 (WJ-FS309/FS409) or 1 to 16 (WJ-FS 316/FS416) regardless of any channels receiving the alarm signal.
ALM - PRI: The video signal of the channel that
received the alarm signal is recorded with more fields than normal.
ALM-ONLY: The recording output is monopolized by
the picture of the channel that received the alarm, while the pictures on other channels are omitted.
Note: ALM-ONLY is not applicable, when a WJ-DR200
AV Disc Recorder is connected to the unit.
GROUP: Up to 4 channels are merged into a group.
When an alarm is received, the video signals of this channel group are recorded with more fields than
normal. If the DYNAMIC REC parameter is on GROUP, proceed as follows:

Alarm Setup Menu

Move the cursor to ALARM SETUP on the SETUP menu, then press the SET button. The ALARM SETUP menu appears on the monitor screen as shown below.
WJ-FS316 SETUP ALARM SETUP
MONITOR OUTPUT SETUP REC OUTPUT SETUP SEQUENCE SETUP SYSTEM SETUP
ALARM SETUP DYNAMIC REC OFF
ALM REC MODE 004 AUTO RESET OFF ALM DISPLAY ON ALM OUTPUT 2S ALM BUZZER 2S ALM INPUT N.O. VIDEO LOSS ON MLT OUT MODE SPOT SPT OUT MODE SPOT
2/2
GROUP SETUP 1/2
CH CH CH CH
ALM 1 1 -- -- -­ ALM 2 2 -- -- -­ ALM 3 3 -- -- -­ ALM 4 4 -- -- -­ ALM 5 5 -- -- -­ ALM 6 6 -- -- -­ ALM 7 7 -- -- -­ ALM 8 8 -- -- --
GROUP SETUP
CH CH CH CH
ALM 1 1 -- -- -­ ALM 2 2 -- -- -­ ALM 3 3 -- -- -­ ALM 4 4 -- -- -­ ALM 5 5 -- -- -­ ALM 6 6 -- -- -­ ALM 7 7 -- -- -­ ALM 8 8 -- -- -­ ALM 9 9 -- -- --
<WJ-FS316/FS416>
<WJ-FS309/FS409>
12
Notes:
If set to EXT, make sure that the CAMERA SW IN terminal on the rear panel is connected to the Time Lapse VCR.
Depending on the mutual timing between the alarm trigger and the field rate, the initial picture recorded after an alarm is activated may not be related to the alarm.
3. AUTO RESET
This item lets you set the time the Video Multiplexer retains the alarm mode before automatic resetting to non-alarm mode. When alarm is activated the display of the camera title on the monitor alternates with ALARM. After the time you set, the previous, non-alarm mode is restored.
1. Move the cursor to the AUTO RESET parameter.
2. Select the desired duration by pressing the + or – but­ton. The initial factory setting is OFF.
OFF: Disables auto reset. 1-30S, 40S, 50S, 1-5M: Selects an alarm duration from
1-30, 40, 50 seconds or 1-5 minutes.
4. ALM DISPLAY
This item lets you enable or disable the Alarm display overlaid on the camera picture while the alarm is activated.
1. Move the cursor to the ALM DISPLAY parameter.
2. Select ON or OFF by pressing the + or – button. The initial factory setting is ON.
ON: Enables alarm display on the monitor. OFF: Disables alarm display on the monitor.
5. ALM OUTPUT
This item lets you select the duration of the Alarm Output signal. When the alarm signal comes in, the Alarm Output signal is supplied to the external device connected. Consult the specifications of the external device on the duration.
1. Move the cursor to the ALM OUTPUT parameter.
2. Select the parameter by pressing the + or – button. The initial factory setting is 2S.
OFF: No Alarm Output signal is supplied, regardless of
an incoming alarm.
1S30S, 40S, 50S, 1M5M: The connected external
device is driven for the duration set here. S and M stand for seconds and minutes.
EXT: The Alarm Output signal continues until the
ALARM RESET button is pressed or an alarm
recovery signal is supplied from the VCR.
6. ALM BUZZER
This item lets you select the ringing duration of the built-in alarm buzzer when alarm is activated.
1. Move the cursor to the ALM BUZZER parameter.
2. Select the duration by pressing the + or – button. The initial factory setting is 2S.
OFF: Disables the alarm buzzer output. 1-30S, 40S, 50S, 1-5M: Selects an alarm duration from
1-30, 40, 50 seconds or 1-5 minutes.
EXT: The alarm buzzer continues to beep until the
ALARM RESET button is pressed or an external
alarm recover signal is received.
7. ALM INPUT
This item lets you select the input form of the alarm signal. Consult the specifications of the sensor device.
1. Move the cursor to the ALM INPUT parameter.
2. Select the parameter by pressing the + or – button. The initial factory setting is N.O.
N.O.: Stands for Normally Open type contact. When
active the contact closes.
N.C.: Stands for Normally Closed type contact. When
active the contact opens.
8. VIDEO LOSS
This item lets you enable or disable the channel loss dis­play on the monitor screen if the video signal is interrupted due to, for example, a cable disconnection.
1. Move the cursor to the VIDEO LOSS parameter.
2. Select ON or OFF by pressing the + or – button. The initial factory setting is ON.
ON: Enables the channel loss display (CHXX LOSS) on
the monitor screen.
Note: XX indicates the channel number.
OFF: Disables the channel loss display on the monitor
screen.
Note: If the video signal is interrupted and the message
CHXX LOSS is displayed, check that the connec­tions are correct and firm, then input the video sig­nal again or press the ALARM RESET button. This resets the channel loss display.
13
9. MLT OUT MODE
This item lets you select whether to switch the multiscreen output monitor screen automatically to the camera picture of the channel whose alarm is activated.
1. Move the cursor to the MLT OUT MODE parameter.
2. Select OFF or SPOT by pressing the + or – button. The initial factory setting is SPOT.
OFF: Ignores alarm activation and continues to display
the pictures in the mode selected previously. All buttons except alarm reset button do not valid on condition that alarm reset does not complete.
SPOT: The camera picture whose alarm is activated is
displayed and retained until the alarm is reset.
10. SPT OUT MODE
This item lets you select whether to switch the spot output monitor screen automatically to the camera picture of the channel whose alarm is activated.
1. Move the cursor to the SPT OUT MODE parameter.
2. Select OFF or SPOT by pressing the + or – button. The initial factory setting is SPOT.
OFF: Ignores alarm activation after and continues to
display the pictures in the mode selected previous­ly. All buttons except alarm reset button do not valid on condition that alarm reset does not complete.
SPOT: The camera picture whose alarm is activated is
displayed and retained until the alarm is reset.

Monitor Output Setup Menu

1. MULTI OUTPUT
Move the cursor to MONITOR OUTPUT SETUP on the SETUP menu, then press the SET button. The MONI­TOR OUTPUT SETUP menu appears on the monitor screen as shown below.
WJ-FS316 SETUP ALARM SETUP
MONITOR OUTPUT SETUP REC OUTPUT SETUP SEQUENCE SETUP SYSTEM SETUP
MONITOR OUTPUT SETUP MULTI OUTPUT
TITLE DISP ON STILL DISP ON BORDER WHITE QUAD SHIFT OFF SECRET VIEW OFF SPOT OUTPUT TITLE DISP ON
1-1. TITLE DISP
This item lets you enable or disable the camera title display overlaid on the multiscreen picture.
1. Move the cursor to the TITLE DISP parameter.
2. Select ON or OFF by pressing the + or – button. The initial factory setting is ON.
ON: Enables display of the camera title. OFF: Disables display of the camera title.
1-2. STILL DISP
This item lets you enable or disable the subtitle STILL overlaid on the multiscreen output picture.
1. Move the cursor to the STILL DISP parameter.
2. Select ON or OFF by pressing the + or – button. The initial factory setting is ON.
ON: Enables display of the subtitle STILL”. OFF: Disables display of the subtitle STILL”.
Loading...