15.48. SS-Board (2 of 2), SS2 and SS3-Board Schematic
Diagram
16 Explo ded Views & Replacement Parts List
16.1. Exploded Views
16.2. Packing Exploded Views (Accessories box)
16.3. Packing Exploded Views (Stand)
16.4. Replacement Parts List Notes
16.5. Mechanical Replacement Parts List (PDP TV)
16.6. Mechanical Replacement Parts List (Stand)
16.7. Electrical Replacement Parts List
TH-58PE75U
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
107
108
109
110
111
112
113
3
TH-58PE75U
1 Applicable signals
4
TH-58PE75U
2 Safety Precautions
2.1. General Guidelines
1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. When wiring units (with cables, flexible cables or lead wires)are supplied as repair parts and only one wireor some of the wires
have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. When conducting repairs and servicing, do not twist the Faston connectors but plugthem straight in orunplug them straightout.
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1Mohm and 5.2Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be
Figure 1
.
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15µF capacitors, between each exposed metallic part on
the set and a good earth ground such as a water pipe, as
shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the ACplugintheACoutlet and repeat eachof the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
5
TH-58PE75U
3 Prevention of Electrostatic Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ESdevices.(Otherwiseham less motion suchasthebrushing
together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to
damage an ES device).
6
TH-58PE75U
4 About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol PbF stamped on the back of PCB.
Caution
· Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 °F (30~40 °C) higher.
Please use a high temperature soldering iron and set it to 700 ± 20 °F (370 ± 10 °C).
· Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
· After applying PbF solder to double layered boards, please check the component side for excess solder which may flow onto
the opposite side. (see figure below)
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder.
However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also be used.
Speaker out, Sound Processor
AV Terminal, AV Switch
Digital Signal Processor, Micon, HDMI Interface
Peaks Lite 2
KRemote receiver, Power LEDSSSustain Drive
SPower SwitchSS2Sustain out (Upper)
GSSD Card Slot, Key SwitchSS3Sustain out (Lower)
C1Data Driver (Lower Right)
C2Data Driver (Lower Center)
C3Data Driver (Lower Left)
SCScan Drive
SUScan out (Upper)
SDScan out (Lower)
8
6 Plasma panel replacement method
6.1. Remove the rear cover
1. See Service Hint (Section 5)
6.2. Remove the rear terminal
cover
1. Remove the screws (×8).
2. Remove the rear terminal cover.
5. Disconnect the connectors (CN06-CN02, CN08-CN1602
and CN1702-CN1601).
6. Remove the screws (×13
TH-58PE75U
).
6.3. Remove the P-Board
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (P2, P6, P7, P9, P10, P11, P12,
and P25).
3. Remove the screws (×8
) and remove the P-Board unit.
7. Remove the molding props (×4).
8. Remove the P(Multi)-Board.
9. Remove the molding props (×7
10. Remove the P(Sus)-Board.
).
4. Remove the screws (×34) on the back side.
9
TH-58PE75U
Note:
When assembling the P(Multi)-Board and the P(Sus)Board, the position of each hole of the insulation sheets(A,
B, C, D) is set to the position of each hole of the P(Multi)Board and the P(Sus)-Board and then assemble them. (
marks indicate setting positions.)
P-Board back side
6.4. Remove the Tuner unit
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (A1, A5, A6, A7, A12 and A52).
3. Remove the screws (×2
4. Remove the screws (×4
) and remove the tuner cover.
) and remove the tuner unit.
P-Board back side
10
6.5. Remove the A-Board
1. Remove the tuner unit. (See section 6.4.)
2. Remove the screws (×6
) and remove the A-Board.
6.6. Remove the D-Board
1. Remove the tuner unit. (See section 6.4.)
2. Disconnect the connectors (D5 and D25).
3. Disconnect the flexible cables (D20, D31 and D32).
4. Remove the screws (×4
) and remove the D-Board.
TH-58PE75U
6.8. Remove the SD-Board
1. Remove the screws (×4).
2. Remove the flexible cables (SD1, SD2, SD3 and SD4)
connected to the SD-Board and remove the connector
(SC46-SD46).
3. Slide the SD-Board to the left to disconnect from a
connector (SC43-SD43 and SC44-SD44) on the SC-Board
and remove the SD-Board.
6.7. Remove the SU-Board
1. Remove the screws (×4).
2. Remove the flexible cables (SU1, SU2, SU3 and SU4)
connected to the SU-Board and remove the connector
(SC45-SU45).
3. Slide the SU-Board to the left to disconnect from a
connector (SC41-SU41 and SC42-SU42) on the SC-Board
and remove the SU-Board.
11
TH-58PE75U
6.9. Remove the SC-Board
6.11. Remove the SS3-Board
1. Remove the SU-Board and SD-Board. (See section 6.7.
and 6.8.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connector (SC2).
4. Disconnect the flexible cable (SC20).
5. Remove the screws (×10
) and remove the SC-Board.
1. Disconnect the connector (SS24) and disconnect the
flexible cable (SS57).
2. Remove the screws (×2
) and remove the SS3-Board.
6.10. Remove the SS2-Board
1. Disconnect the connector (SS23) and disconnect the
flexible cable (SS52).
2. Remove the screws (×2
) and remove the SS2-Board.
6.12. Remove the SS-Board
1. Disconnect the connectors (SS11, SS12 SS23, SS24,
SS33 and SS35).
2. Remove a short-jumper connector SS34 and re-use for new
SS-Board.
3. Disconnect the flexible cables (SS54 and SS55).
4. Remove the screws (×7
) and remove the SS-Board.
12
6.13. Remove the stand brackets
and rear mounting metals
1. Remove the plasma panel section from the servicing stand
and lay on a flat surface such as a table (covered) with the
plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screw (×2
each).
3. Remove the rear mounting metals (left, right) fastening
screws (×4
4. Remove the stand brackets and rear mounting metals.
each).
TH-58PE75U
6.15. Remove the C2-Board
1. Remove the tuner unit. (See section 6.4.)
2. Remove the flexible cables holder fastening screws (×8
).
3. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
4. Disconnect the flexible cables (C20, C21 and C22).
5. Remove the screws (×6
) and remove the C2-Board.
5. Remove the fastening screws (×4each).
6. Remove the stand brackets from rear mounting metals.
6.14. Remove the C1-Board
1. Remove the tuner unit. (See section 6.4.)
2. Remove the stand bracket (right) and the rear mouting
metal (right). (See section 6.13.)
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB1, CB2, CB3, and CB4).
5. Disconnect the flexible cables (C10 and C11).
6. Remove the screws (×6
) and remove the C1-Board.
6.16. Remove the C3-Board
1. Remove the tuner unit. (See section 6.4.)
2. Remove the stand bracket (left) and the rear mouting metal
(left). (See section 6.13.)
3. Remove the flexible cables holder fastening screws (×6
).
4. Disconnect the flexible cables (CB9, CB10 and CB11).
5. Disconnect the flexible cable (C32).
6. Disconnect the connectors (C33 and C35).
7. Remove the screws (×5
) and remove the C3-Board.
13
TH-58PE75U
6.17. Remove the front bracket and
the front shield case cover
1. Disconnect the connector (A52). (See section 6.4.)
2. Remove the screws (×4
and the front shield case cover.
) and remove the front bracket
6.18. Remove the GS-Board
1. Remove the front bracket and the front shield case cover.
(See section 6.17.)
2. Remove the screws (×2
top and the control button.
) and remove the front shield
6.20. Remove the S-Board
1. Remove the screws (×2) and remove the S-Board metal
frame.
2. Disconnect the connector (S2).
3. Remove the screws (×2
) and remove the S-Board.
3. Remove the screws (×2) and disconnect the connector
(GS52).
4. Remove the GS-Board.
6.19. Remove the speaker L, R
1. Disconnect the connector (A12). (See section 6.4.)
2. Remove the screws (×4
L, R.
each) and remove the speaker
6.21. Remove the K-Board
1. Remove the S-Board. (See section 6.20.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connector (A1). (See section 6.4.)
4. Remove the screws (×2
5. Disconnect the connectors (K1 and K2) and remove the KBoard.
) and remove the K-Board.
14
6.22. Remove the Plasma panel
section from the Cabinet assy
(glass)
1. Remove the stand brackets (left, right) fastening screw (×2
each).
2. Remove the cabinet assy and the plasma panel fastening
screws (×10
).
TH-58PE75U
3. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
4. Remove the spacers and spacer rings (×6).
6.23. Replace the plasma panel
(finished)
1. Place the new plasma panel (finished) on the flat surface of
the table (covered by a soft cloth), with the plasma panel
surface facing downward.
2. Attach the C1-Board, C2-Board and the C3-Board, connect
the flexible cables (×22) from the plasma panel to the C1Board, C2-Board and the C3-Board, and fit the flexible
cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow
any debris, dust or handling residue to remain between
the front glass and plasma panel.
15
TH-58PE75U
7 Caution statement
7.1. Caution statement.
Caution:
Please confirm that all flexible cables are assembled correctly.
Also make sure that they are locked in the connectors.
Verify by giving the flexible cables a very slight pull.
16
8 Location of Lead Wiring
8.1. Lead of Wiring (1)
TH-58PE75U
17
TH-58PE75U
8.2. Lead of Wiring (2)
18
8.3. Lead of Wiring (3)
TH-58PE75U
19
TH-58PE75U
9 Self-check Function
Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
9.1. Check of the IIC bus lines
9.1.1. How to access
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote
control for more than 3 seconds.
9.1.2. Exit
Disconnect the AC cord from wall outlet.
9.1.3. Screen display
9.1.4. Check Point
Confirm the following parts if NG was displayed.
20
9.2. Power LED Blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
TH-58PE75U
21
TH-58PE75U
9.3. No Power
First check point
There are following 2 states of No Power indication by power LED.
1. No lit
2. Red is lit then turns red blinking a few seconds later. (See 9.2.)
22
9.4. No Picture
TH-58PE75U
23
TH-58PE75U
9.5. Local screen failure
Plasma display may have local area failure on the screen. Fig-1 is the possible defect P.C.B. for each local area.
Fig-1
24
10 Service Mode
10.1. How to enter into Service Mode
While pressing [VOLUME ( - )] button of the main unit, press [RECALL] button of the remote control three times within 3
seconds.
10.1.1. Key command
“1” button...Main items Selection in forward direction
“2” button...Main items Selection in reverse direction
“3” button...Sub items Selection in forward direction
“4” button...Sub items Selection in reverse direction
“VOL” button...Value of sub items change in forward direction ( + ), in reverse direction ( - )
TH-58PE75U
25
TH-58PE75U
10.1.2. Contents of adjustment mode
·Value is shown as a hexadecimal number.
·Preset value differs depending on models.
·After entering the adjustment mode, take note of the value in each item before starting adjustment.
COUNT
ALL WHITE
ALL RED
ALL GREEN
ALL BLUE
ON/OFF
RAMP WHITE
RAMP RED
RAMP GREEN
RAMP BLUE
1% WINDOW
COLOR BAR
A-ZONE B-ZONE/4 TRIO
SCROLL
WHITE FLAME
RM-SETCODEAFixed
SRV-TOOL-See next
10.1.3. How to exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
26
TH-58PE75U
10.2. Service tool mode
10.2.1. How to access
1. Select “SRV-TOOL” in Service Mode.
2. Press [OK] button on the remote control.
10.2.2. Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by “Self-check indication and forced to factory
shipment setting”.
10.2.3. POWER ON TIME/COUNT Note: To display TIME/COUNT menu, highlight position, then press MUTE for (3sec).
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not cleared by either of the self-check or any other command.
10.2.4. Exit
1. Disconnect the AC code from wall outlet.
27
TH-58PE75U
11 Adjustment Proce dure
11.1. Driver Set-up
11.1.1. Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Vivid
Normal: Set
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-100V, Voltage of Vscn is 45V ±4V.
11.1.2. Adjustments
Adjust driver section voltages referring the panel data on the
panel data label.
Check or adjust the following voltages with the multimeter.
VbkTPVBK (SC)155V ± 1VVR6604 (SC)
SS BoardVeTPVE (SS)Ve ± 1VVR6000 (SS)*
D, DG BoardWhite balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
29
TH-58PE75U
11.4. Adjustment Volume Location
11.5. Test Point Location
30
Loading...
+ 104 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.