This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
21. Exploded View and Replacement Parts List 130
21.1 Indoor Unit ............................................... 130
21.2 Outdoor Unit ............................................ 134
1. Safety Precautions
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the
power plug and main circuit for the model installed.
The caution items stated here must be followed because these important contents are related to safety. The
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction
will cause harm or damage, and the seriousness is classified by the following indications.
WARNING
CAUTION
The items to be followed are classified by the symbols:
Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation,
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for
future reference.
1. Do not modify the machine, part, material during repairing service.
This indication shows the possibility of causing death or serious injury
This indication shows the possibility of causing injury or damage to properties.
This symbol denotes item that is PROHIBITED from doing.
WARNING
2. If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit.
3. Do not wrench the fasten terminal. Pull it out or insert it straightly.
4. Engage authorized dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water
leakage, electrical shock or fire.
5. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire.
6. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire
or electrical shock.
7. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done,
the set will drop and cause injury.
8. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet
must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
9. This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD).
Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown.
10. Do not use joint cable for indoor/outdoor connection cable. Use the specified indoor/outdoor connection cable, refer to installation instruction
CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor/outdoor connection. Clamp the cable so that no external force
will be acted on the terminal. If connecting or fixing is not perfect, it will cause heat up or fire at the connection.
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause
heat-up or fire at the connection point of terminal, fire or electrical shock.
12. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle
(piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may
climb up to outdoor unit and cross over the handrail and causing accident.
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and
telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown.
15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.
16. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with
other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.
17. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may
break and cause refrigerant gas leakage.
18. For R410A model, use piping, flare nut and tools which is specified for R410A refrigerant. Using of existing (R22) piping, flare nut
and tools may cause abnormally high pressure in the refrigerant cycle (piping), and possibly result in explosion and injury.
Thickness or copper pipes used with R410A must be more than 1/32" (0.8 mm). Never use copper pipes thinner than 1/32" (0.8 mm).
It is desirable that the amount of residual oil is less than 0.0008 oz/ft (40 mg/10 m).
3
19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping
and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
20. During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of refrigeration piping while compressor is
operating and valves are opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury
etc.).
21. After completion of installation or service, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant
contacts with fire.
22. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fire.
23. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
24. Must not use other parts except original parts describe in catalog and manual.
25. Using of refrigerant other than the specified type may cause product damage, burst and injury etc.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the
unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage
the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare
may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
WARNING
CAUTION
5. Select an installation location which is easy for maintenance.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
7. Power supply connection to the room air conditioner.
Power supply cord shall be UL listed or CSA approved 3 conductor with minimum AWG14 (For E9RK and E12RK) and AWG12
(For E18RK and E24RK) wires.
Power supply point should be in an easily accessible place for power disconnection in case of emergency.
In some countries, permanent connection of this air conditioner to the power supply is prohibited.
Fix power supply connection to a circuit breaker for permanent connection.
Use NRTL approved fuse or circuit breaker (rating refers to name plate) for permanent connection.
8. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take
care of the liquid refrigerant, it may cause frostbite.
9. Installation or servicing work: It may need two people to carry out the installation or servicing work.
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
11. Do not sit or step on the unit, you may fall down accidentally.
12. Do not touch the sharp aluminium fins or edges of metal parts.
If you are required to handle sharp parts during installation or servicing, please wear hand glove.
Sharp parts may cause injury.
4
2. Specification
Model
Performance Test Condition ARI ARI
Power Supply
Min. Mid. Max. Min. Mid. Max. Min. Mid. Max. Min. Mid. Max.
Capacity
Running Current A - 4.2 - - 3.8 - - 5.5 - - 5.0 -
Input Power W 250 860 1.00k250 860 1.00k250 1.13k 1.30k 250 1.13k 1.30k
EER
Cooling
Heating
Compressor
Indoor Fan
Power Factor % - 98 - - 98 - - 99 - - 98 -
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Capacity
Running Current A - 4.6 - - 4.2 - - 4.5 - - 4.0 -
Input Power W 200 950 1.50k200 950 1.50k200 910 1.71k 200 910 1.71k
COP
Power Factor % - 99 - - 98 - - 97 - - 99 -
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Max Current (A) / Max Input Power (W) 5.3 / 1.20k 7.0 / 1.61k
Starting Current (A) 4.6 5.5
Min Circuit Ampacity 15.0 15.0
Max. Current Protection 15.0 15.0
SEER / HSPF 16.00 / 8.50 16.00 / 8.50
Type Hermetic Motor / Rotary Hermetic Motor / Rotary
Motor Type Brushless (6 poles) Brushless (6 poles)
Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) 3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft) 15 (49.2) 15 (49.2)
Piping
Additional Gas Amount g/m (oz/ft) 20 (0.2) 20 (0.2)
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Drain Hose
Inner Diameter mm (inch) 16.7 (5/8) 16.7 (5/8)
Length mm (inch) 650 (25-5/8) 650 (25-5/8)
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Indoor Heat
Exchanger
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 15 × 21 2 × 15 × 21
Size (W × H × L) inch 1 × 12-13/32 × 24 1 × 12-13/32 × 24
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Outdoor
Heat
Exchanger
Air Filter
Fin Type Corrugate Fin Corrugate Fin
Row × Stage × FPI 2 × 24 × 17 2 × 24 × 17
Size (W × H × L) inch
1-13/32 × 19-13/16 × 28-1/16
26-15/16
1-13/32 × 19-13/16 × 28-1/16
26-15/16
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Outdoor Outdoor
Power Supply Cord A - -
Thermostat - -
Protection Device - -
6
Model
DRY BULB WET BULB DRY BULB WET BULB
Indoor Operation Range
(Cooling) (°F / °C)
Outdoor Operation Range
(Cooling) (°F / °C)
Indoor Operation Range
(Heating) (°F / °C)
Outdoor Operation Range
(Heating) (°F / °C)
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
Indoor CS-RE9SKUA CS-RE12SKUA
Outdoor CU-RE9SKUA CU-RE12SKUA
Maximum 89.6 / 32 73.4 / 23 89.6 / 32 73.4 / 23
Minimum 60.8 / 16 51.8 / 11 60.8 / 16 51.8 / 11
Maximum 114.8 / 46 78.8 / 26 114.8 / 46 78.8 / 26
Minimum 0 / -17.8 - / - 0 / -17.8 - / -
Maximum 86.0 / 30 - / - 86.0 / 30 - / -
Minimum 60.8 / 16 - / - 60.8 / 16 - / -
Maximum 75.2 / 24 64.4 / 18 75.2 / 24 64.4 / 18
Minimum -4 / -20 -2.2 / -19 -4 / -20 -2.2 / -19
7
Model
Performance Test Condition ARI ARI
Power Supply
Min. Mid. Max. Min. Mid. Max. Min. Mid. Max. Min. Mid. Max.
Capacity
Running Current A - 7.00 - - 6.30 - - 11.70 - - 10.50-
Input Power W 430 1.40k 1.55k430 1.40k 1.55k430 2.39k 2.55k 430 2.39k 2.55k
EER
Cooling
Heating
Compressor
Indoor Fan
Power Factor % - 96 - - 97 - - 98 - - 99 -
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Capacity
Running Current A - 6.90 - - 6.20 - - 8.8 - - 7.9 -
Input Power W 380 1.38k 1.75k380 1.38k 1.75k380 1.78k 2.45k 380 1.78k 2.45k
COP
Power Factor % - 96 - - 97 - - 97 - - 98 -
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Max Current (A) / Max Input Power (W) 12.1 / 2.74k 12.5 / 2.87k
Starting Current (A) 7.0 11.7
Min Circuit Ampacity 15.0 20.0
Max. Overcurrent Protection 20.0 25.0
SEER / HSPF 16.00 / 8.50 16.00 / 8.50
Type Hermetic Motor / Rotary Hermetic Motor / Rotary
Motor Type Brushless (4 poles) Brushless (4 poles)
Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6) 3 (9.8) ~ 20 (65.6)
I/D & O/D Height different m (ft) 15 (49.2) 15 (49.2)
Piping
Additional Gas Amount g/m (oz/ft) 20 (0.2) 20 (0.2)
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Drain Hose
Inner Diameter mm (inch) 16.7 (5/8) 16.7 (5/8)
Length mm (inch) 650 (25-5/8) 650 (25-5/8)
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Indoor Heat
Exchanger
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 15 × 21 2 × 15 × 21
Size (W × H × L) inch 1 × 12-13/32 × 31-7/8 1 × 12-13/32 × 31-7/8
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Outdoor
Heat
Exchanger
Air Filter
Fin Type Corrugate Fin Corrugate Fin
Row × Stage × FPI 2 × 31 × 19 2 × 31 × 19
Size (W × H × L) inch
1-13/32 × 25-5/8 × 33-5/8
32-15/32
1-13/32 × 25-5/8 × 33-5/8
32-15/32
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Outdoor Outdoor
Power Supply Cord A - -
Thermostat - -
Protection Device - -
9
Model
DRY BULB WET BULB DRY BULB WET BULB
Indoor Operation Range
(Cooling) (°F / °C)
Outdoor Operation Range
(Cooling) (°F / °C)
Indoor Operation Range
(Heating) (°F / °C)
Outdoor Operation Range
(Heating) (°F / °C)
1. Cooling capacities are based on indoor temperature of 80°F DRY BULB, 67°F WET BULB and outdoor air temperature of 95°F DRY BULB,
75°F WET BULB.
2. Heating capacities are based on indoor temperature of 70°F DRY BULB, 60°F WET BULB and outdoor air temperature of 47°F DRY BULB,
43°F WET BULB.
3. Specifications are subjected to change without prior notice for further improvement.
Indoor CS-RE18SKUA CS-RE24SKUA
Outdoor CU-RE18SKUA CU-RE24SKUA
Maximum 89.6 / 32 73.4 / 23 89.6 / 32 73.4 / 23
Minimum 60.8 / 16 51.8 / 11 60.8 / 16 51.8 / 11
Maximum 114.8 / 46 78.8 / 26 114.8 / 46 78.8 / 26
Minimum 0 / -17.8 - / - 0 / -17.8 - / -
Maximum 86.0 / 30 - / - 86.0 / 30 - / -
Minimum 60.8 / 16 - / - 60.8 / 16 - / -
Maximum 75.0 / 24 64.4 / 18 75.0 / 24 64.4 / 18
Minimum -4 / -20 -2.2 / -19 -4 / -20 -2.2 / -19
10
3. Features
Inverter Technology
o Wider output power range
o Energy saving
o Quick Cooling
o More precise temperature control
Environment Protection
o Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping
o CS/CU-RE9/12SK, long piping up to 65 feet (20 meters)
o CS/CU-RE18/24SK, long piping up to 100 feet (30 meters)
Easy to use remote control
Quality Improvement
o Random auto restart after power failure for safety restart operation
o Gas leakage protection
o Prevent compressor reverse cycle
o Inner protector to protect Compressor
o Noise prevention during soft dry operation
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
Serviceability Improvement
o Breakdown Self Diagnosis function
11
4. Location of Controls and Components
A
2
3
O
2
3
4.1 Indoor Unit
Aluminium Fin
Front PanelAir Filters
Auto OFF/ON button
• Use when remote control is misplaced
or a malfunction occurs.
Horizontal airflow
direction louver
• Manually adjustable.
(RE9SK and RE12SK).
• Do not adjust by hand.
(RE18SK and RE24SK).
4.2 Outdoor Unit
ir inlet (side)
POW
T
Remote control
receiver and Indicator
Vertical airflow direction louver
• Do not adjust the flap by hand.
Air inlet (rear)
ER
R
E
IM
L
U
F
R
POWE
T
E
I
QU
Indicator
POWER
TIMER
POWERFUL
QUIET
(Green)
(Orange)
(Orange)
(Orange)
Air outlet
4.3 Remote Control
OFF/ON
TEMP
TEMP
FAN SPEED
2
FAN
SPEED
AIR
SWING
AIR SWING
SET
3
CANCEL
AC
RC
Remote control
display
Operation mode
Temperature setting
Powerful/Sleep mode
operation
CheckCheck
AUTO
HEAT
COOL
DRY
FAN
MODE
POWERFUL/
QUIET
TIMER
ON
1
OFF
SET CHECK CLOCK RESET
CHE
RE9SK RE12SK
OFF/ON
Vertical airflow
direction selection
Fan speed selection
Timer setting
Clock setting
Remote control
Operation mode
Temperature setting
Powerful/Sleep mode
operation
12
display
AUTO
HEAT
COOL
DRY
FAN
MODE
POWERFUL/
QUIET
TIMER
TIMER
ON
1
FF
SET CHECK CLOCK RESET
OFF/ON
TEMP
FAN SPEED
2
FAN
SPEED
AIR
SWING
AIR SWING
SET
3
CANCELOFF
CANCEL
AC
RC
RE18SK RE24SK
OFF/ON
Airflow direction
selection
Fan speed selection
Timer setting
Clock setting
5. Dimensions
1
2
3
5.1 Indoor Unit
5.1.1 CS-RE9SKUA CS-RE12SKUA
<Side View><Side View>
Air intake
direction
<Top View>
<Front View>
(8-7/16)
8-7/16
Left piping
hole
Air outlet
direction
1/32~1/16
<Bottom View>
4-29/32
<Rear View>
34-9/32
Gas side
Liquid side
1/32~1/16
2-11/322-11/32
4-17/32
11-7/16
Right piping
hole
Remote control
1-7/8
FAN
AUTO
SPEED
HEAT
AIR
COOL
SWING
DRY
FAN
OFF/ON
MODE
TEMP
TEMP
AIR SWING
POWERFUL/
FAN SPEED
QUIET
5-1/4
TIMER
SET
3
1
2
CANCELONOFF
AC
RC
SETCHECK CLOCK RESET
CHE
Remote control holder
2-3/8
2
2-13/32
1-49/64
7/8
16-1/8
(1-5/8~2-13/32)
Relative position between the indoor unit and the installation plate <Front View>
Installation
plate
Indoor unit
external
dimensions
line
29-29/64
Left
piping
hole
5-1/16
3-3/4
1-11/16
5-1/16
9-17/329-17/32
1717-9/32
Right
piping
hole
5/8
10-3/8
Unit: inch
13
5.1.2 CS-RE18SKUA CS-RE24SKUA
O
1
2
3
<Top View>
<Side View><Side View>
Air intake
<Front View>
direction
(9-15/32)
9-15/32
Left piping
hole
Air outlet
direction
1/32~1/16
<Bottom View>
<Rear View>
2-11/32
42-5/32
1/32~1/16
2-11/32
11-7/16
2-13/32
1-49/64
Right piping
hole
Remote control
1-7/8
AUTO
FAN
SPEED
HEAT
COOL
DRY
AIR
SWING
FAN
OFF/ON
MODE
TEMP
POWERFUL/
AIR SWING
FAN SPEED
QUIET
5-1/4
TIMER
TIMER
SET
ON
3
1
2
FF
CANCELOFF
CANCEL
AC
4-17/324-29/32
SETCHECK CLOCK RESET
RC
7/8
Remote control holder
2-3/8
2
Installation
plate
Indoor unit
external
dimensions
line
(1-39/64~2-13/32)16-9/64
Relative position between the indoor unit and the installation plate <Front View>