CONNECTION
ZD1
ZD2
50mA max.
50mA max.
Sensor circuit
Load
Load
Color code of cable type
(Brown)V (Black) Output 1 (White) Output 2 (Blue) 0V
Internal circuit
Users’ circuit
 
5 to 24V DC
10%
50mA max.
50mA max.
ZD1
Tr3
ZD2
Tr4
Sensor circuit
Load
Load
Color code of cable type
(Brown)V (Black) Output 1 (White) Output 2 (Blue) 0V
Internal circuit
Users’ circuit
 
5 to 24V DC
10%
2
CAUTIONS
Since the sensor is intended for use inside machines, no special counter­measures have been taken against extraneous light. Please take care that extraneous light is not directly incident on the beam receiving section.
NPN output type
PNP output type
mOutput operation Output 1: Light-ON Output 2: Dark-ON
mOutput operation Output 1: Light-ON Output 2: Dark-ON
When the connector CN-14 is inserted into the connector type PM-54(P), insert it satraight till the hook of the connector is fitted to the hook of the sensor. In order to pull the connector out, hold the connector body and then apply a force to the extent that the hook of the connector comes off from the hook of the sensor.
If soldering in done directly on the terminals of the connector type
PM-54(P) and the connector CN-14, solder them under the following conditions: temperature 260C or less, time 3 sec. or less, soldering position 1.5mm or more away from terminal base.
If the sensor is used in a place having excessive dust, periodically clean the emitting and receiving sections with a dry, soft cloth.
Cable extension is possible up to an overall length of 100m with a 0.3mm
2
, or more, cable. However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor or at the sensor terminals is within the rating.
But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage.
I
f there is a large surge generating equipment, such as, motor, sole-
noid, electromagnetic valve, etc., in the vicinity of the micro-photo­sensor, use a surge absorber on that equipment. Further, do not run the sensor cables along power lines and use a capacitor between
V and 0V, if required. Use after confirming
that the surge has been eliminated.
In case the sensor is fixed with screws, strictly observe the following conditions.
5 to 24V DC
d
10%
Overall length: 100m
Supply voltage: 4.5V or more
Cable attached to sensor, or sensor terminals
V
Output
0V
Extension cable
Overall cable length
Wire conductor cross-section area
Up to 5m Up to 10m Up to 20m
0.08 to 0.1mm
2
0.2mm
2
0.3mm
2
Do not use the sensor in the transient time duration of 50ms after
switching on the power supply.
The cable of
PM-24-R
is a flexible cable usable on a moving base. When the sensor is mounted on a moving base, fix the sensor cable joint so that stress is not applied to it.
Take care that the flexibility of the
PM-24-R
cable is lost if the
ambient temperature is near -10
C
.
Note:
If the ultra-small type PM-24(-R) is used at an ambient temperature of 50C or more, make sure to mount it on a metallic body.
Screw
Tightening torque
Washer
PM-44(P), PM-54(P)PM-24(-R)
M3
0.5Nm or less
"6mm (small diameter type)
M2
0.15Nm or less
"4.3mm (small diameter type)
SUNX Limited
Head Office
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
Overseas Sales Dept.
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
http://www.sunx.co.jp/
PRINTED IN JAPAN
WARNING
Never use this product as a sensing device for personnel protection.
I
n case of using sensing devices for personnel protec­tion, use products which meet standards, such as OSHA, ANSI or IEC etc., for personnels protection applicable in each region or country.
WARNING
Take care not to apply any force to the terminal of the connector type PM-54(P) and the connector CN-14. Furthermore do not plug in/pull out the connector more than 10 times, since it can cause contact-failure.
Since protection circuit against output short-circuit or reverse polarity connection is not incorporated, make sure to wire correctly. Also, ensure to insulate the unused output wire. Take care that wrong wiring will damage the sensor.