Panasonic Pid4 Operating Instructions

Manufactured by:
!
81-IN3061-9922
Before attempting to connect or operate this product, please read these instructions completely.
for
MODEL: Indoor Ceiling Housing PID4
DESCRIPTION
• This product has been designed and engineered for the unitized camera WV-CS854 for ease of installation and service.
• This product is a discreet indoor recessed surveillance enclosure designed to mount into a drop ceiling tile or sheet rock ceiling.
• This unit completely encloses the unitized camera WV-CS854, resulting in discreet viewing.
STANDARD INSTALLATION PROCEDURE
1. Carefully remove all equipment from the box.
2. Using the template provided, cut a 7.0" hole into the
ceiling in the desired spot. (See #8 below for special note)
3. Remove the desired conduit knockout from the side of the PID4 housing.
4. Remove the trim ring by pulling on the outside of the it. The ring is connected by three flat springs, which press against the side of the housing and lock into (3) cutouts.
PRODUCT INSTRUCTIONS
Use to attach housing to solid ceiling
Figure 3
9. Run electrical cable into the housing through one of the three conduit knockouts.
10. Detach the camera mounting base from the camera and mount it to the PID4 housing using the (4) 8-32 x 1/2" Phillips screws provided in packet (Figure 4).
Use with Class 2 Power Supply only.
Figure 4
11. Complete all electrical and video connections (Figure 5).
Figure 1
7. Support wires (not provided) must be connected to the top of the housing through the two provided slots
(Figure 2).
Figure 2
CAUTION: The wires must be able to support up to 15 lbs (6.8 kg).
8. If the housing is going into a ceiling where the support arms will not work, the housing can be secured to the ceiling by running bolts (not provided) through the bottom flange into the solid ceiling (Figure 3).
NOTE: If you use bolts instead of support wires the hole will need to be the same size and shape as the top of the housing. DO NOT USE THE 7" TEMPLATE. Use the top of the housing as a template to cut out the hole.
Figure 5
12. Attach the WV-CS854 camera to the camera mounting base and secure with the safety screw provided with the camera.
13. Reattach the PID4 trim ring by pressing in and sliding the three flat spring clips into the housing. Make sure the spring clips are aligned with the three spring clip slots. You will feel all three spring clips snap into place when the trim ring is correctly secured (Figure 6).
Figure 6
Completed Installation
SPECIFICATIONS
Metal Back Box 18- and 20-gauge steel, w/black powdercoat finish Support Arms 18-gauge Galvanized steel Decorative Trim Ring 19-gauge steel w/textured off-white powdercoat finish Electrical Input (3) .875" knockouts Unit Weight 3.5 lbs (1.6 kg)
A B
C D
3.29
5.04
7.25Ø
1.24
DIMENSIONS
6.25
6.91
1.81
.25Ø
4.50Ø
.23
E F
G H
8.00
DESCRIPTION QTY.
A PID4 Housing 1 B Support Arms 3 C Camera Mounting Base 1 D 8-32 x 1/2" Phillips screws 4 E 8-32 X 1 1/2" Phillips screws 3 F WV-CS854 Unitized Camera 1 G PID4 Spring Clip 3 H PID4 Trim Ring 1
- 2 -
1. Read Instructions - All the safety and operating instructions
!
should be read before the unit is operated.
2. Retain Instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should be followed.
5. Electrical Connections - Only a qualified electrician should make electrical connections.
6. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7. Cable Runs - All cable runs must be within permissible distance.
8. Mounting - This unit must be properly and securely mounted to
a supporting structure capable of sustaining the weight of the unit. Accordingly:
a. The installation should be made by a qualified service person, and should conform to all local codes. b. Care should be exercised to select suitable hardware to install the unit, taking into account both the composition of the mounting surface and the weight of the unit. Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the installation is intact. Failure to comply with the foregoing could result in the unit separating from the support structure and falling, with resultant damages or injury to anyone or anything struck by the falling unit.
SAFETY PRECAUTIONSIMPORTANT SAFEGUARDS
CAUTION
RISK OF
ELECTRIC SHOCK!
CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT EXPOSE
COMPONENTS TO WATER OR MOISTURE.
The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to
!
UNPACKING
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper.
presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Be sure to save:
1. The shipping carton and packaging material. They are the safest material in which to make future shipments of the equipment.
2. These Installation and Operating Instructions.
SERVICE
Panasonic Technical Center 54 West Gude Dr. Rockville MD 20850-1150
Phone: 301-762-5125 Fax: 301-251-0347
PANASONIC TECHNICAL SUPPORT
1-800-528-6747
9:00 AM - 5:00 PM EASTERN TIME
- 3 -
Loading...