Panasonic KV-S3105C User Manual

Panasonic KV-S3105C Scanner Maintenance
Pull the front door release
Illustration 1
Important!!!
Do NOT use canned air to clean scanner. The air can force dust behind the scan glass. This is a quick reference guide – please see operator guide for more detailed instructions. For additional information or questions, please call 1-800-PANASYS (1-800-726-2797).
To Access Inside of Machine (Caution: Turn off scanner prior to cleaning. Also, be aware that conveyor
area may be hot).
towards you.
1. Clean approximately every 20,000 scans.
a. It may need cleaning more frequently, depending on the material being scanned. b. Also, clean the rollers if paper misfeeding or double-feeding occurs frequently.
i. Roller cleaning kit (KV-SS03) is recommended. If you do not have the cleaning kit, you may
use a microfiber cloth with a small amount of isopropyl alcohol or water.
ii. Do Not use detergent, thinner or benzene as this can damage the rollers.
iii. Cleaning kit (KV-SS03) can be purchased from your reseller.
iv. Clean all rubber feed rollers.
1
Illustration 2
Note: When wiping off the dirt on the rollers,
Open the DFP (double-feed prevention) Roller
Clear the Clean Roller Warning after cleaning.
Clean the scan glasses if vertical streaks appear on scanned images.
After cleaning rollers, Press the key and the key
hold the roller to prevent it from turning. Wipe the rollers all the way around in the direction of the arrows.
Door as shown in picture 3 below. Wipe the DFP roller in direction shown (illustration 4).
Illustration 3 Illustration 4
Then close DFP roller door.
Clean the 6 drive rollers and 6 free rollers as shown below
Clean both scan glasses
simultaneously. The “Clean Roller Warning” will be cleared. Then “Completed” will be displayed.
Use a dry, microfiber cloth to clean the glass. If dirt remains on glass, you may use an alcohol wipe followed by the microfiber cloth.