Panasonic FX-551 Instruction Manual

INSTRUCTION MANUAL
Digital Fiber Sensor Amplier
Thank you very much for purchasing Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
FX-551
Series
ME-FX551 No.0058-72V
WARNING
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
This product is not equipped with an automatic interference prevention function. By setting different frequencies, interference can be prevented for up to four units. For the setting method, refer to <PRO3> in “
1 INTENDED PRODUCTS FOR CE MARKING
● This product complies with the following standards / regulations.
<EU Directive>
EMC Directive
2 PART DESCRIPTION
UP key
Teaching
Threshold value ne
adjustment Select setting items
12
PRO MODE
SET key
Teaching
Conrm setting
contents
.”
DOWN key
Teaching
Threshold value ne
adjustment Select setting items
4
INSTALL MORE AMPLIFIER OF SERIES CONNECTION TYPE
(Connection type only)
● Make sure that the power supply is OFF while adding or removing the series connection type.
● This product is not equipped with an automatic interference prevention function. By setting different frequencies, interference can be prevented for up to four units. For the setting method, refer to <PRO3> in “
● In case 2 or more the series connection types are connected in cascade, make sure to mount them on a DIN rail.
● In case installing additional amplifier of series connection type, the maximum 15 the series connection types using sub cables (optional) can be added to an
amplier using a main connection cable. (optional)
● When connecting 2 or more the series connection types in cascade, use the sub cable (optional) for the second series connection type onwards.
For mounting and removing the amplier, refer to “
How to cascade
1.
Mount the ampliers, one by one, on
the DIN rail.
2.
Slide the ampliers next to each other,
and connect the quick-connection cables.
3.
Mount the end plates
MS-DIN-E
(optional) at both the ends to hold the
ampliers between their at sides.
4.
Tighten the screws to fix the end
plates.
How to Remove
1.
Loosen the screws of the end plates.
2.
Remove the end plates.
3.
Slide the ampliers and remove them
one by one.
12
PRO MODE
3
MOUNTING
End plate MS-DIN-E (Optional)
End plate MS-DIN-E (Optional)
.”
.”
Sub cable (Optional)
Slide
Main cable (Optional)
Slide
Sensing output operation indicator (Orange)
Lights when setting SENSING OUTPUT OPERATION MODE
Lights when setting LIGHT SENSITIVITY SETTING MODE
<Reference>
Pressing down SET key + MODE key for 3 sec : Set key lock or release key lock
Digital display (Green / Red)
MODE indicator: L / D (Yellow)
MODE indicator: CUST (Yellow)
MODE indicator: PRO (Yellow)
Lights when setting PRO mode
MODE key
Select modes
Cancel during setting
3 MOUNTING
How to mount
1.
Fit the rear part of the mounting section of
the amplier on a DIN rail.
2.
Press down the rear part of the mounting
section of the unit on the DIN rail and t the
front part of the mounting section to the DIN rail.
How to remove
1.
Push the amplier forward.
2.
Lift up the front part of the amplier to remove
it.
How to connect the ber cable
● Mount the ber cables in the state power is not supplied.
● Be sure to t the attachment to the bers rst before inserting the bers to the
amplier. For details, refer to the instruction manual enclosed with the bers.
● Insert the ber cables slowly into the inlets until they stops. Excessive force may damage the product.
1.
Snap the fiber lock lever down till it stops completely.
2.
Insert the ber cables slowly into the inlets
until they stops. (Note)
3.
Return the fiber lock lever to the original position till it stops.
Note: With the coaxial reective type ber, insert the single core ber cable into the beam-emitting inlet “P” and the
multi-core ber cable into the beam-receiving inlet.
If they are inserted in reverse, the sensing performance will deteriorate.
2. Press down
2. Lift up
Fiber lock lever
Fiber for emitter
35mm width DIN rail
1. Push forward
1. Snap
3. Return
2. Insert
Fiber for receiver
1. Fit
5 I/O CIRCUIT DIAGRAMS
< NPN output type >
(Brown) +V (Note)
Main circuit
(Black) Sensing output
(Blue) 0V (Note)
Load
+
12 to 24V DC
+10
%
‒15
< PNP output type >
(Brown) +V (Note)
+
(Black) Sensing output
Main circuit
Note: The quick-connection sub cable does not incorporate +V (brown) and 0V (blue). The power is supplied from the
connector of the main cable.
(Blue) 0V (Note)
Load
12 to 24V DC
+10
%
‒15
< FX551□ terminal arrangement >
1
2
3
Terminal No. Terminal name
1 +V
2 Sensing output
3 0V
6 OPERATION PROCEDURE
The changed settings are not stored if turning the power OFF while setting.
Therefore, conrm the settings by pressing the SET key before turning the power
OFF.
● When turning ON the power, RUN mode is displayed and the digital display shows the threshold value (green) and the incident light intensity (red).
<RUN mode>
<Sensing output operation mode>
<Light sensitivity setting mode>
• Displays threshold value (green) and incident light intensity (red).
Teaching, threshold value ne adjustment and key lock function can be set.
• For setting method of each function, refer to “
8
THRESHOLD VALUE FINE ADJUSTMENT FUNCTION,” or “
KEY LOCK FUNCTION.”
• Select either Light-ON or Dark-ON.
• For the setting, refer to “
• The default setting is “ ” (Light-ON).
• Displays light sensitivity setting and enables its setting.
• For detailed information, refer to “
MODE.”
10
SENSING OUTPUT OPERATION MODE.”
11
7
TEACHING MODE,”
LIGHT SENSITIVITY SETTING
9
<PRO mode>
<RUN mode>
Detailed settings can be set for maximizing the performance of individual functions.
• For setting items and setting method, refer to “
12
PRO MODE.”
7 TEACHING MODE
Be sure that detection may become unstable depending on the use environment in teaching if less margin is applied.
● Teaching can be set in RUN mode.
Useful when sensing object can be set
2-point teaching
1
2
This is basic teaching method.
<Mirror reection type>
1
2
1. Press the SET key in the sensing object present condition.
2. Press the SET key in the sensing object absent condition.
<Reective type><Thru-beam type>
1 2
8 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION
● Set the ne adjustment of threshold value in RUN mode.
Press down UP / DOWN key
Press down SET key
Conrmed
Automatically set without pressing down SET
key in approx. 2 sec.
9 KEY LOCK FUNCTION
● The key lock function prevents key operations so that the conditions set in each setting mode are not inadvertently changed.
● If operating key switch after key lock is set, “ ” is indicated on the digital display.
<Set key lock>
Press down SET
+ MODE keys
simultaneously for
3 sec or longer
<Release key lock>
Press down SET
+ MODE keys
simultaneously for
3 sec or longer
Automatic
Automatic
Stable sensing is possible
Stable sensing is not possible
Useful when sensing object cannot be set
Limit-teaching
<Common to thru-beam type, mirror reection type and reective type>
Note: The shift value of approx. 15% is an initial value. Display of the shift value can be changed to
percentage [approx. 0 to 999% (unit 1 %)] or incident light intensity [0 to 9999 (unit 1)].
For setting the shift amount, refer to <PRO1> in “
This is teaching method in case small object or object in
back ground are existing.
or
1.
Press the SET key in the sensing object present condition or non sensing object present condition.
12
2.
Thru-beam type, mirror reflection type: Threshold level is shifted to high value (low sensitivity) when UP key is pressed down, and it is shifted to low value (high sensitivity) when DOWN key is pressed down. (Note)
Reflective type: Threshold level is
shifted to high value (low sensitivity) when DOWN key is pressed down, and it is shifted to low value (high sensitivity) when UP key is pressed down. (Note)
Stable sensing is possible
Stable sensing is not possible
PRO MODE
.”
are displayed
10
SENSING OUTPUT OPERATION MODE
,
● When MODE indicator: L / D (yellow) lights up, sensing output operation can be set.
Press down
UP / DOWN key
11
LIGHT SENSITIVITY SETTING MODE
Press down
SET key
Conrmed
Conrmed
● When the MODE indicator: CUST (yellow) lights up, light sensitivity setting can be displayed.
● By pressing down UP key or DOWN key, light sensitivity setting can be changed.
● Press SET key to conrm the setting.
SET key DOWN key
UP key
Press down UP / DOWN key
MODE indicator CUST (Yellow)
MODE key
Press down
SET key
Conrmed
Useful when not want to stop production line and to keep the sensing object move
Full-auto teaching
<Common to thru-beam type, mirror reection type and reective type>
This is method to conduct teaching doing sensing object is moving.
1. Pressing SET key down
Pressing
down long
2. Run the sensing object on the line and hold down the SET key.
3.
” is displayed on the digital display (green) and
when the sensing object passed through, release the SET
Automatic
key.
Stable sensing is possible
Stable sensing is not possible