Panasonic fv-gkf32S1 operating instructions

BOTTOM
indication
Main unit (Wall thickness: 4-7/20" (110 mm) - 12" (305 mm))
①Choose a place to install.
*Install this unit when outer and inner walls are completed.
Through hole
φ
3-11/32" (85 mm)
20" (60 mm)
More than 70.87"
(1800 mm)
More than
2-7/20" (60
mm)
②Make a through hole ((3-11/32"
(8 5m m )) on a wall at a down-
ward inclination of 1/100 to 1/50
to outside.
If t he duc t is covered by an
adiabatic mate ri al , ma ke a
hole including the thickness of
the adiabatic material.
BOTTOM
⑦The knob should be pushed in
all the way toward the BOTTOM
mark on the main body in order
to mount the wall bracket.
⑧Move t he sh ut ter h an dle t o
open the shutter.
Wall
bracket
Main
body
Knob
Shutter
handle
Open
Close
indication
Outside hood
①Separate the outside hood from
the frame. Insert the duct into
the opening of the frame, and
screw down lower part of the
frame on the outer wall with two
screws.
②Connect two hooks at the bot-
tom of the outside hood with the
frame, and push until the click
sound is heard.
③Tighte n u ppe r p art of the
outside hood with a screw.
④Caulk around the periphery
of the unit with a caulking
material so that rain water
does not come in.
Frame
Screw
Frame
Hook
(2 places)
Outside
hood
Screw
Caulking
Outside
hood
Tape
Weight
Loosen
Tighten
Main
body
Duct
Screw
Wall
(Water resis tant mortar)
(Backup mate rial)
Caulking mat erial
Duct
Inclination
(1/100 - 1/5 0)
Indoor
Outdoor
④Remove the tape that fastens
the air shutter.
⑤Adjust the weight according to
the required amount of air to be
venti la te d in t he r oo m. (T he
weight should balance with the
amount of air ventilated.)
Factory setting: 18 cfm (30 cmh)
Remove the weight: 12 cfm (20
cmh)
(In addi tion to the we ight, re-
move a hexagon nut and spring
washer also.)
When r emoving the weight,
use a pinch or hexagon bar
spanner (nominal diameter 4
mm).
⑥Embed a duct in a wall, and in-
sert the main body without the
wall bracket into the duct, and
secure with four screws.
Duct should be installed so
that it has a downward incli-
nation of 1/100 - 1/50 toward
outdoor.
Du c t an d w a l l sho u l d b e
sealed completely so that no
rainwater comes in.
Mak e sur e that the d uct i s
piped all the way to the out-
door.
③Cut out the packed duct according to the wall thickness. If
the wall thickness is more than 6" (150 mm), connect two
ducts with a tape to extend the length.
Panasonic Canada Inc.
5770 Ambler Drive Mississauga,
Ontario, L4W 2T3
Panasonic Corporation of North America
Two Riverfront Plaza , Newark , NJ07102
www.panasonic.com
INSTALLATION METHOD (Follow the instructions below for installtion.)
1. This unit must be installed on a firm surface. There is a possibility of personal injury due to falling.
2. Attach parts firmly. There is a possibility of personal injury due to falling.
3. Do not install this unit in places exposed to an open flame. Plastic parts may deform and ignite to cause a fire.
4. Do not install this unit on a ceiling.
Shutter will not function.
5. Do not install this unit where temperature may exceed 104
o
F (40
o
C) or much oily smoke is produced.
It may cause deformation and damage to the outside hood and main body.
6. Do not use in places where chemicals and special gas are used.
It may cause deformation and damage to the outside hood.
7. Caulk around the periphery of the unit with a caulking material so that rain water does not come in.
2-7/10" (69)
1-3/16"
(30)
2-7/10" (68)
1-2/5"
(35.5)
3/10" (8)
6" (152)
3-4/5" (96)
5-7/10" (144)
ø3-3/8"(85)
6" (150)
1-7/10"
(43)
2-1/25"
(52)
4/5"(22)
6-1/10" (155)
13/20" (16.5)
6" (150)
1-3/10"
(34)
ø3-3/16"(81)
ø6-3/5" (169)
(45 )
o
(45
)
o
INSTALLATION
INSTRUCTIONS
FV-GKF32S1
Screw ............................... 7 pcs.
(SUS ø4 mm x 30 mmL)
Operating Instructions ....... 1 (must be handed to the
customer.)
Insect
screen
Outside
hood
GENERAL INFORMATION Observe the following
PART NAMES AND DIMENSIONS
4/5"(22)
2-1/25"
(52)
1-7/10"
(43)
6-1/10"(155)
13/20"(16.5)
6"(150)
φ3-3/16"(81)
45°)
45°)
Hook
Wall bracket
Shutter
Shutter handle
Air shutter
Weight
Filter fixing spring
Main body
Air filter
Knob
Close Open
下側
1-3/10"
(34)
φ
6-3/5"(169)
1-3/16"
(30)
2-7/10"(68)
1-2/5"
(35.5)
6"(152)
3-4/5"(96)
5-7/10"(144)
3/10"(8)
2-7/10"(69)
For fixing screw (3places)
Insect
screen
Outside
hood
Frame
Drain hole
Main body Outside hood
Unit: Inch (mm)
Duct
×
2 pcs.
Accessories
Printed in Japan
GKF324051DS1-P0701-4103