Before using your air conditioner, please read
this operating instructions carefully and keep it
for future reference.
...... 11
FEATURES
● Self-illuminating Button
For your convenience to operate in the dark.
(Refer page 4)
● Automatic Operation
Sense indoor temperature to select the optimum
mode.
(Refer page 5)
● Sleep Mode
Prevent the room from getting too hot or too cold
while you are sleeping.
(Refer page 7)
● Economy Mode
To reduce electrical power consumption.
(Refer page 7)
● Powerful Mode
Reaches the desired room temperature quickly.
(Refer page 7)
● Removable Front Panel
For quick and easy cleaning. (washable)
(Refer page 8)
● Catechin Air Purifying Filter
Filter that can trap dust, tobacco smoke and tiny
particles in the room. It can also prevent growth of
bacteria and viruses trapped in this filter.
(Refer page 8)
● Solar Refreshing Deodorizing Filter
Used to remove unpleasant odour and deodorize the
air in the room.
(Refer page 8)
● Auto Restart Control
Restart the unit automatically after power failure.
(Refer page 9)
● Blue Coated Condenser At Outdoor Unit
This is the most advanced anti-rust coating.
! Warning
1) Operate your air conditioner from a stable 208/230 volts
AC supply.
2) Plug into a separate 15 amps grounded outlet only.
3) Use of extension cords.
Avoid using extension cords. If there are no alternatives,
ensure that the cord is a UL listed 3-wire grounding type,
rated 250 volt with a minimum current-carrying rating of
15 amps, number 16 or a heavier wire.
4) Use a 15 amps time delay fuse or a circuit breaker.
5) Do not switch off by unplugging the power plug while it is
operating. Turn off the air conditioner by using remote
control, before unplugging.
6) Remove power plug or disconnect from the main before
servicing this appliance.
7) Do not repair by yourself.
In case of malfunction of this appliance, do not repair by
yourself. Contact the sales dealer or service dealer for a
repair.
8) Turn off the power (Isolation from main power supply).
Pull off the power plug from the receptacle, or switch off
the breaker, or switch off the power disconnecting mean
to isolate the equipment from the main power supply in
case of an emergency.
! Caution
DISCONNECT THE MAIN PLUG FROM THE SUPPLY
SOCKET WHEN NOT IN USE, WHERE SUPPLY
CONNECTION IS VIA MAIN PLUG.
POWER SUPPLY
Time Delay Fuse:Line Cord Plug:
15 Amps
Rated Volts:Socket Type:
208/230 V
1
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
● To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
● Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
! Warning
This sign warns of death or serious injury.
! Caution
This sign warns of damage to property.
● The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
■ Installation Precautions
! Warning
● Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
! Caution
● This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
● Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
● Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
■ Operation Precautions
! Warning
This sign warns of death or serious injury.
● Do not share outlet.
● Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
● Do not operate with wet hands.
● Do not damage or modify the power cord.
● Do not insert finger or other objects into the
indoor or outdoor units.
● Do not expose directly to cold air for a long
period.
● Plug in properly.
● Use specified power cord.
FF
O
● If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.
! Caution
This sign warns of injury.
● Do not pull the cord to disconnect the plug.
● Do not wash the unit with water.
● Do not use for other purposes such as
preservation.
● Do not use any combustible equipment at
airflow direction.
● Do not sit or place anything on the outdoor
unit.
ENGLISH
FF
O
These symbols (with a black background) denote
actions that are COMPULSORY.
● Switch off the power supply before cleaning.
● Ventilate the room regularly.
● Pay attention as to whether the installation
rack is damaged after long period of usage.
OFF
● Switch off the power supply if the unit is not
used for a long period.
2
NAME OF EACH PART
UT
UT
DR
AN
COOL
UT
■ Indoor Unit
1
1 Front Panel
2 Air Intake Vent
3 Power Supply Cord
4 Air Outlet Vent
5 Vertical Airflow Direction Louver
6 Horizontal Airflow Direction Louver
(manually adjusted)
7 Indicator Panel
123654
POWERFULPOWERFULECONOMYECONOMYPOWERPOWER
POWERFULPOWERFULECONOMYECONOMYPOWERPOWER
2
4576
● Indoor Unit
■ Accessories
(when the front panel is opened)
● Remote Control
1
3
2
1 Front Panel
3
AU
T
O
C
O
O
N
O
L
OFF
AU
D
T
R
F
O
YFA
N
AU
POWERFUL
FAN
TEMP
T
M
A
I
S
tep
1
ON
OFF
C
H
E
TIM
C
K
R
E
E
R
S
E
T
C
C
LO
C
K
+
B
A
T
T
E
R
Y
O
O
D
E
OFF/ON
ECONOMY
R
S
W
IN
G
S
L
E
E
P
2
FAN SPEED
3
SET
A
N
C
E
L
● Remote Control Holder
2 Air Filters
3 Air Purifying Filter
■ Outdoor Unit
● Two RO3 (AAA) dry-cell batteries or equivalent
1
6
SLEEPSLEEP
TIMERTIMER
SLEEPSLEEP
TIMERTIMER
2
3
● Air Purifying Filter
4
5
1 Auto Operation Button
(when the front panel is opened)
2 Economy Mode Indicator – GREEN
3 Powerful Mode Indicator– ORANGE
4 Power Indicator– GREEN
5 Sleep Mode Indicator– ORANGE
6 Timer Mode Indicator– ORANGE
3
1 Air Intake Vents
2 Ground Terminal
(Inside cover)
3 Piping
4 Connecting Cable
5 Drain Hose
6 Air Outlet Vents
(Catechin Air Purifying Filter)
(Solar Refreshing Deodorizing Filter)
NAME OF EACH PART
CHECK
TEMP
AUTO
ON
OFF
AUTODRYFAN
F
COOLCOOL
FAN
AUTO
RESET CLOCK
MODE
SLEEP
ECONOMY
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
POWERFUL
AUTO
MANUAL
#
!
$
%
^
$
*
&
3
5
8
7
9
0
6
4
(
AUTO
OF
AUTOHEAT
DRY
FANCOOL
FAN
AUTO
AUTO
SLE
● How to Insert the Batteries
ENGLISH
■ Remote Control
1
2
● Remote Control Signal.
● Notes for Remote Control.
• Make sure it is not obstructed.
• Maximum distance : 10 m (32.8 ft.).
• Signal received sound.
One short beep or one long beep.
• Do not throw or drop.
• Do not get it wet.
• Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
1 Signal Transmitter
2 Operation Display
3 Powerful Mode Operation Button
4 Room Temperature Setting Button
(self-illuminating button)
2
PO
W
ERFU
L
MODE
AIR SWING
AUTO
ECONOMY
1
MANUAL
ON
OFF
2
CANCEL
SET
FAN SPEED
3
1.5V
CHECK
1.5V
TIMER
RESET
CLOCK
5 Operation Mode Selection Button
6 Economy Mode Operation Button
1
7 Auto Airflow Direction Button
8 ON-Timer Button
1 Slide down the remote control cover completely
9 OFF-Timer Button
2 Insert the batteries
0 Reset Point
(Press with fine-tipped object to clear the memory)
! OFF/ON Button
(self-illuminating button)
@ Sleep Mode Operation Button
# Fan Speed Selection Button
$ Manual Airflow Direction Selection Button
% Timer Set Button
^ Timer Cancellation Button
& Time-Setting Button
* Clock Button
( Remote Control Cover
– Be sure the direction is correct
– 12.00 at display - flashing
• Set the current time (CLOCK) immediately to
prevent battery exhaustion.
● About the batteries
• Can be used for approximately one year.
● Observe the following when replacing the
batteries
• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be
used for a long period.
4
PREPARATION BEFORE OPERATION
CHECK
AUTO
AUTOHEATDRYFANCOOL
FAN
AUTO
RESET CLOCK
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
AUTO
MANUAL
1
2
OFF
ON
HEAT
DRY
FANCOOL
CHECK
TEMP
AUTO
AU
T
UTO
FA
N
AN
AU
T
UTO
R
ESET
CLO
C
K
AIR SWING
OFF
CANCEL
1
2
3
TIMER
OFF/ON
POW
ERFUL
AUTO
MANUAL
ECONOMY
SLEEP
ON
SET
FAN SPEED
MODE
■ Indoor Unit
HOW TO OPERATE
■ Setting Temperature
• Press 3 to increase or decrease the temperature.
• The temperature can be set between 60°F ~ 86°F.
• Recommended temperature:
2
1
6
3
5
4
1 Connect the power supply cord to an independent
power supply
2 Open the front panel
3 Remove the air filters
4 Fit the air purifying filters in place
5 Insert the air filters
6 Close the front panel
■ Remote Control
– To set the current time
2
3
5
1
6
4
■ To start the operation
• Press 1.
• POWER indicator (green) on the indoor unit will light
1 Press 1.
2 Then press 2 to increase or decrease the time.
3 Press 1 again.
Set time at display will light up.
5
• Once the Automatic Operation is selected, the
indoor temperature sensor operates automatically
to select the desired operation mode with Cooling
or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
■ Setting the Fan Speed
• Press 4 to select:-
FAN– Low Fan Speed
FAN– Medium Fan Speed
FAN– High Fan Speed
AUTO
FAN–Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
■ Setting the Horizontal Airflow Direction
• Adjust it manually
● Operation Details
COOL – Cooling Operation
• To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
• Sense indoor temperature to select the optimum
mode.
• Temperature is not displayed on the remote control
during AUTO operation.
ENGLISH
■ Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
COOL / DRY Operation
AUTO
36°
Swing up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
FAN Operation
AUTO
61°
Swing up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.
● Notes
• If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
• If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
DRY – Soft Dry Operation
• A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
• During Soft Dry operation, the indoor fan operates at
Low fan speed.
FAN – Air Circulation Operation
• When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
4°F below the set temperature.
(It is useful when using a heater).
6
AUTO
AUTOHEATDRYFANCOOL
FAN
AUTO
MODE
SLEEP
ECONOMY
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
POWERFUL
AUTO
MANUAL
3
6
4
1
7
5
2
8
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
■ ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
■ OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
● Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
COOL, DRY,15 minutes
AUTOin advance
• Once the ON-Timer is set, operation will start at the
set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
7
CONVENIENCE OPERATION
■ Sleep Mode Operation
To obtain a comfortable room temperature while
sleeping:-
• Press 6.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
● Sleep Mode Operation Details
• When the room temperature reaches the set
temperature, the airflow volume will change to low
automatically.
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a
priority.
Temperature
S
T
e
e
m
t
p
t
e
i
r
n
a
g
t
u
r
e
Sleep
Operation
button is
pressed.
0~1 hour
Approx.
1°F
increase.
Sleep shift
operation
starts.
← 1 hour →
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Approx. 1°F
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
Time
■ Economy Mode Operation
To save electrical power consumption.
Please use this mode when the room has reached
your desired temperature.
• Press 7.* Economy mode indicator (green) on the indoor unit
will light up.
• Press once more to cancel this operation.
■ Powerful Mode Operation
To obtain the set temperature quickly.
• Press 8.* Powerful mode indicator (orange) on the indoor
unit will light up.
* Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.
●
Economy / Powerful Mode Operation Details
• Economy and Powerful operation cannot be
selected simultaneously.
• The changes of the temperature and airflow volume
are automatic.
• The remote control display remains unchanged.
• If sleep button or operation mode button is pressed,
economy or powerful operation will be cancelled.
• During FAN – Air circulation operation, the powerful
and economy operation are not available.
Airflow
volume
Super Low
Super High
Economy Mode
Operation
Powerful Mode
Operation
Temperature
1°F higher
than set temp.
5°F lower
than set temp.
Loading...
+ 17 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.