Panasonic CSC281KR, CUC281KR User Manual

Room Air conditioner
Operating Instructions
Model CS–C281KR (Indoor)
CU–C281KR (Outdoor)
Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.
1
Safety Precautions.........................................2-4
– Installation precautions – Operation precautions
Name of Each Part
.........................................
5-6
– Indoor unit – Outdoor unit – Accessories – Remote control
Preparation Before Operation..........................7-8
– Before operating the unit – How to insert batteries – Operating the remote control
How to Operate...........................................9-10
Setting the Timer ......................................11-12
Convenient Operation................................13-14
– Sleep mode – When remote control cannot be used – OFF/ON remote control signal receiving
sound
Operation Hints.........................................15-16
Better Care and Maintenance.....................17-18
– Cleaning the air conditioner and air filters – Replacement of air purifying filters – When not using the air conditioner for a
long period
– Pre-season inspection
Troubleshooting ........................................19-20
– Normal operation – Abnormal operation – Call the dealer immediately
Before use
If necessary
How to use
Safety Precautions
2
Before operating, please read the following “Safety Precautions” carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instructions will cause harm or damage, the seriousness of which is classified as follows:
The instructions to be followed are classified by the following symbols:
Warning: Caution :
This sign warns of death or serious injury.
This sign warns of injury or damage to property only.
This symbol (with a white background) denotes an action that is PROHIB­ITED.
These symbols (with a black background) denote an action that is COM­PULSORY.
Installation precautions
Do not install, remove and reinstall the unit yourself.
Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work.
Warning
This room air conditioner must be earthed. Ensure that drainage piping is connected
properly.
Do not install the unit in a place where there may be explosive gas leaks.
Caution
Improper grounding could cause electric shock.
Gas leaks near the unit could cause fires.
Otherwise, water will leak out.
Y Y
Y
Y
3
Operation precautions
Insert the power plug proper­ly.
Heat generated by a loose power plug could cause electric shock or fire. Electrical outlet and power plug shall be easilly accessible.
Do not operate or stop the unit by inserting or pulling out the power plug.
It could cause electric shock or fire.
Do not damage or use an unspecified power cord.
It will cause electrical shock or fire.
Do not modify the length of the power cord or use an extension cord.
It could cause electric shock or fire.
Do not modify the length of the power cord or use an extension cord.
It could cause electric shock or fire.
Do not operate the unit with wet hands.
It could cause an electric shock.
Do not insert finger, sticks or other objects into the units.
It could lead to physical injury and cause damage to the units.
Do not be directly exposed to the cold airstream for too long.
It could lead to health problems.
If there is a smell of burning, stop the air conditioner and disconnect the power supply.
The heat generated could cause electric shock or fire. Please consult an authorized dealer or service centre.
Do not try to repair the unit yourself.
It could lead to fire or cause an electric shock. Please call an authorized dealer or service centre.
Switch off the breaker.
Disconnect the power plug.
Warning
Y
4
Do not remove the power plug by pulling the cord.
Hold the plug when disconnec­ting the plug from the wall outlet.
Switch off the power supply if the unit is not going to be used for a long period of time.
If dust accumulates on the plug, it will generate heat and this could cause a fire.
When cleaning the unit, re­move the plug.
This is to prevent injury due to the rotating fan in the unit.
Do not use for other purposes.
Do not use for preservation pur­poses. It will affect food quality, animals or plants.
Do not place combustor in the path of the airflow from the unit.
Incomplete combustion could cause toxic gas (CO) poisoning.
Ventilate the room regularly.
If not ventilated regularly, the lack of oxygen could cause headaches.
Do not wash the unit with water.
It could cause an electric shock.
Inspect the unit for any dam­age.
Ensure that the necessary repairs are carried out.
Do not sit or place anything on the outdoor unit.
You might fall off or the unit might collapse.
Switch off the breaker.
Disconnect the power plug.
Caution
Y
Name of Each Part
5
Indoor unit
Outdoor unit
Front Panel
Air Intake Vent
Panel Opener
Vertical Airflow
Direction Louver
Air Outlet Vent
Horizontal
Airflow Direction Louver
(Manually adjusted)
Signal Receptor
Operation Indication
Lamps (LED)
Air Intake Vents
Air Outlet Vents
(Side)
(Rear)
Ground Terminal (Inside Cover)
Piping
Drain Hose
Power Sleep Timer
Red Orange Orange
6
Remote control
Accessories
Remote Control
Two R03 dry-cell batteries or equivalent
Air Purifying Filters
Signal Transmitter
Operation Display
Sleep Mode Operation Button
OFF/ON Button
Airflow Volume Selection Button
Airflow Direction Manual Control Button
Room Temperature Setting Button
Operation Mode Selection Button
Airflow Direction Auto Control Button
Separate displays and functions are available when the door is opened.
Door
OFF-Timer Button
Time Button
ON-Timer Button
Door
Cancellation Button
Clock Button
Set Button
OFF-TIMER TIME ON-TIMER
SETCANCEL
Preparation Before Operation
7
Before operating the unit
Connect the power supply cord to an independent power supply.
1
2
Open the front panel.
Hold the panel openers at both sides and pull up the front panel.
3
Remove air filter.
Insert air purifying filter. Insert the air filters.
Hold the tab to raise up slightly and then pull down.
Air filter
Be careful not to hurt your hands by metal parts.
Air purifying filter
<Note>
Use under the following conditions:
(Unit in ˚C)
DBT: Dry Bulb Temperature
Cooling
WBT: Wet Bulb Temperature
In door Out door
DBT WBT DBT WBT
Maximum Temperature 32 23 43 26
Minimum Temperature 16 11 16 11
Loading...