Panasonic AW-PB506AL User Manual

ENGLISHITALIANO
Studio SDI Card
AW-PB506AL
This product consists of an SDI card and an interface bracket.
FRANÇAIS DEUTSCH
ESPAÑOL
РУССКИЙ
Before attempting to connect, operate or adjust this product,
please read these instructions completely.
中 文
ENGLISH VERSION
Safety precautions
DO NOT REMOVE PANEL COVERS BY UNSCREWING.
To reduce the risk of electric shock, do not remove the covers. No user serviceable
parts inside.
Refer servicing to qualified service personnel.
WARNING:
• TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
• TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, KEEP THIS EQUIPMENT AWAY FROM ALL LIQUIDS. USE AND STORE ONLY IN LOCATIONS WHICH ARE NOT EXPOSED TO THE RISK OF DRIPPING OR SPLASHING LIQUIDS, AND DO NOT PLACE ANY LIQUID CONTAINERS ON TOP OF THE EQUIPMENT.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, REFER CHANGES OF SWITCH SETTINGS INSIDE THE UNIT TO QUALIFIED SERVICE PERSONNEL.
indicates safety information.
- 1 (E) -
Information on Disposal for Users of Waste Electrical & Electronic
Equipment (private households)
This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to designated collection points, where they will be accepted
on a free of charge basis. Alternatively, in some countries you may be able to return your products to your local retailer upon the purchase of an equivalent new product. Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
Information on Disposal in other Countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact your local authorities or dealer and ask for the correct method of disposal.
ENGLISH
- 2 (E) -

Contents

Configuration ........................................ 3
Accessories .......................................... 3
Introduction ........................................... 4
Characteristics ...................................... 4
Precautions for use .............................. 4
Major operating controls and
their functions ................................. 5
SDI card ........................................... 5
Interface bracket .............................. 6
Installing the SDI card .......................... 7
Interface bracket mountings ............... 8
Mounting the bracket on a tripod ..... 8
Mounting the camera ....................... 8
Mounting the viewfinder
on a bracket .................................. 8

Configuration

SDI card (AW-PB506A U01) ................... 1
Interface bracket (AW-PB506A U02) .... 1
Connections .......................................... 9
When configuring a system
with the remote control unit ......... 9
When configuring a system
with the remote operation panel
Setting and changing of menu items
Performing the settings .................. 11
Optional card settings submenu .... 13
Appearance ......................................... 14
SDI card ......................................... 14
Interface bracket ............................ 15
Specifications ..................................... 16
... 10
... 11

Accessories

Adjuster plug (M6 M3) ........................ 1
Screws (6 mm) ....................................... 2
Screws (8 mm) ....................................... 4
- 3 (E) -

Introduction

Installing the SDI card in a convertible camera (such as the AW-E350, AW-E650, AW-E655, AW-E750 and AW-E860) and mounting the camera on the interface bracket makes it possible for a viewfinder and/or inter-communications headset to be used and thus enable the camera to be used as a studio camera. In addition, there are two signal outputs for SDI signals c
ompliant with EBU Tech.3267-E standard.

Characteristics

Two signal outputs for SDI signals compliant with the EBU Tech.3267-E standard (BBC No. PSF1/2M, BELDEN 8281 or equivalent coaxial cable; max. 200 m)
EDH (Error Detection and Handling)
flags complying with the SMPTE RP165 standard can be added. ( A switch can be used to enable or
disable the addition of these flags.)
An inter-communications headset can be
used and its volume adjusted.
The STANDBY/ON switch function of the viewfinder (WV-VF65B, AW-VF80) is incorporated.
Notes
The AW-PB506A cannot be installed
to the following models; AW-E300, AW-E300A, AW-E300S, AW-E600, AW-E800, AW-E800A, AW-RP605, AW-PB605
When the SDI card unit is to be
discarded at the end of its service life, ask a specialized contractor to dispose of it properly in order to protect the environment.
Output signals (brightness and
composite video signals) to the viewfinder can be switched using the menu settings.
Zebra pattern and safety zone displays
appearing in the viewfinder can be switched using the menu settings.
The VIDEO ON/OFF switch function of the viewfinder (AW-VF64) is incorporated. ( In order to prevent CRT burn-in, the
AW-VF64 does not come with a standby function.)
ENGLISH

Precautions for use

When connecting or disconnecting a
cable from any unit, ensure that the power to that unit is turned off.
Do not drop this product or subject it to
strong shock or vibration, as this may cause it to malfunction.
- 4 (E) -
Avoid using the unit in very humid or
dusty locations, as this may cause it to malfunction.
Avoid using the product at a cold place
below –10°C or at a hot place above +45°C because extremely low or high temperature will adversely affect the parts inside.

Major operating controls and their functions

SDI card

EVF I/F connector [EVF I/F]
The EVF I/F cable 9 from the interface bracket is connected here.
SDI output 1, 2 connector
[SDI OUT 1, 2]
SDI signals are output from here.
Setting switches
SW NO OFF ON 1 EDH ENABLE DISABLE 2 SETTING E350 E860 3 DATA CLIP NORMAL CLIP 4 NTSC/PAL NTSC PAL
1: EDH <ENABLE/DISABLE>
(Factory setting: ENABLE) An EDH flag is added to SDI output at the ENABLE setting.
2: Model selection <E350/E860>
(Factory setting: E350) When the AW-E350, AW-E650, AW-E655 or AW-E750 is used, set this switch at the E350. When the AW-E860 is used, set this switch at the E860.
3: DATA CLIP <NORMAL/CLIP>
(Factory setting: NORMAL) At the NORMAL setting, signal input is output at the same level at which it was input. At the CLIP setting, signal input at less than 0% is output at 0%, and signal input at more than 100% is clipped at 100%.
4: NTSC/PAL switching <NTSC/PAL>
(Factory setting: NTSC) Leave this switch at the factory setting.
- 5 (E) -
Loading...
+ 11 hidden pages