Panasonic AK-HRP900P User Manual

Page 1
Before attempting to connect, operate or adjust this product,
please read these instructions completely and save this manual for future use.
Model AK-HRP900P
Camera Controller
Page 2
2
FCC Note:
This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached instal­lation instructions and do not make any unauthorized modifications.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are de­signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equip­ment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
1 is the safety information.
CAUTION
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and main­tenance (servicing) instructions in the literature accompanying the appliance.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE RECOM­MENDED ACCESSORIES ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
The serial number of this product may be found on the bottom of the unit.
This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
For CANADA
12 Volt Class II Power Supply Only. (For Example: AW-PS505P)
Page 3
3
Contents
For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Check the Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Precautions for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Controls and their Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
_ Operation panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
_ Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
_ Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
How To Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
_ Lens connection in the case of no swivel stand . . . . . . . . . . . . . . . . . . . . . . .13
Multi-purpose digital camera control system configuration 1 . . . . . . . . . . . . . . .14
Multi-purpose digital camera control system configuration 2 . . . . . . . . . . . . . . .15
Multi-purpose digital camera control system configuration 3 . . . . . . . . . . . . . . .16
Communication speed setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Example of Rack Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
_ How to rack-mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
_ How to change the rear panel position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Appearance and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Page 4
4

Outline

Coupling . . . . . . . . . . . . . . . . . . . . . . .1 pc
Multi-cable . . . . . . . . . . . . . . . . . . . . . .1 pc
Seal . . . . . . . . . . . . . . . . . . . . . . . . . . .1 pc
Setscrews . . . . . . . . . . . . . . . . . . . . .8 pcs
M4 x 8 mm . . . . . . . .4 pcs
M5 x 8 mm . . . . . . . .4 pcs
This unit is a camera controller for multi-purpose camera (AK-HC900P). This
unit is connected to a multi-purpose camera with one multi-cable, and capable of transmitting and receiving various camera and lens control signals, analog picture signals of cameras, and generator lock signals (3-value SYNC).
The extension distance between this unit and the camera is 33 ft (10m) max.It is possible to control the swivel stand from the pan-tilt control panel AW-
RP301 by using the swivel stand control input connector.

Check the Accessories

Precautions for Use

We recommend that the AC adapter AW-PS505P is used for power supply.Handle the unit with care.
If dropped or given a strong shock, it may cause a trouble or accident.
Use the unit in a temperature range of 32oF to 104oF (0oC to + 40oC).
If used at a temperature below 32oF or higher than 104oF, it may cause bad influences to the component parts.
Turn off the power before connecting or disconnecting the cable.
When connecting or disconnecting the cable, be sure to turn off the power switch of the unit beforehand.
Avoid using the unit outdoors.Install the unit 3.3 ft (1 m) away from the monitor.Maintenance
Pull out the power cord plug and clean the unit with dry cloth. If it is hard to clean, moisten the cloth with a diluted neutral detergent solution and squeeze it well and lightly wipe the unit.
Do not use volatile solvents such as benzene or thinner.When using a chemical mop, carefully read the instructions.
Precautions
Page 5
5

_Operation panel

POWER
ON OFF
SD CARD
OPERATE
ALARM
SCENE
MODE
PRE
CAM BAR TEST
USER1 USER2
Camera Controller
TALLY
MENU
ON
MENU
SPEED ZOOM
TELE
WIDE
FAR
NEAR
FOCUS
12345
PRESET
CC FLTER
3200
CROSS
63004300
ND FLTER
CLEAR 1/321/161/4
SHUTTER
OFF
SYNCRO
STEP
GAIN
0
S1 S2
S3
9dB 18dB
AUTO
WHITE BLACK
GAIN
BLACK
AUTO
M-PED
IRIS
CHECK
123<=>
? @ A
B C
D E
F G
: ;HIJ K L
4 5 6
7
8
9
1 Power indication LED [POWER]
It is lighted green when the power control switch 2 is ON. It goes out when the power control switch 2 is OFF.
2 Power control switch [POWER ON/OFF]
With this switch turned ON, the unit and the camera connected are simultaneously turned on. With it turned OFF, both of the unit and the camera are turned off.
3 SD card slot [SD CARD]
With an SD card inserted, the camera setting data can be recorded on the SD card.
4 Tally LED [TALLY]
It is lighted red when tally signal is input to the tally signal input terminal Q.

Controls and their Functions

Page 6
6
5 Menu operation switch [MENU]
Operation switch for camera menu. Item selection or data change can be done by turning this switch. When this switch pushed, the item and data are settled.
6 Menu ON switch [MENU ON]
Used to turn the camera menu ON/OFF.
7 Preset memory switch [MEMO]
Preset memory can be done up to 5 points with respect to lens zoom, focus, and iris position (when iris select switch K is at [MANU]). When using the preset memory, first set the lens focus, zoom, and iris. Next, push this switch, then the switch is lighted. Subsequently, push the desired preset position select switch 8. With the data stored in the memory, the switch is lighted.
8 Preset position select switch [PRESET]
It calls the lens zoom, focus and iris settings previously stored in the memory, and brings the lens into preset operation.
9 Speed change switch [SPEED]
High speed operation is obtained when the zoom operation lever : and the focus adjust lever ; are operated while pressing this switch. The switch is lighted while being pressed.
: Zoom operation lever [ZOOM TELE/WIDE]
Used for zoom operation of the lens. The zoom speed changes with the shifting angles of the lever. With the zoom operation lever direction change switch T set at [NOR], when the lever is shifted to [TELE], the zoom operates in a telescopic mode, and when shifted to [WIDE], it operates in a wide angle mode. With the zoom operation lever direction change switch T set to [REV], the zoom can be operated in the opposite direction.
; Focus adjust lever [FOCUS FAR/NEAR]
Used to adjust the lens focus. The focus can be controlled in speed variable fashion by regulating the shifting angle of this lever. With the focus adjust direction change switch U set at [NOR], when this lever is shifted to [FAR], the focus is adjusted to a far distance, and when shifted to [NEAR], the focus is adjusted to a near distance. With the focus adjust direction change switch U set to [REV], the focus can be adjusted in the opposite direction.
< Operation panel active switch [OPERATE]
This is an active switch for panel function. It can be operated when the switch is lighted. It does not work when the switch is not lighted.
Controls and their Functions
Page 7
7
Controls and their Functions
= Alarm indication LED [ALARM]
It lights up when an alarm is generated (in case of fan stop, wrong communication speed, etc.).
Note:
In case of wrong communication speed, change the DIP SW position in the unit to match the camera and communication speed so that the alarm goes out.
> Scene file select switch [SCENE]
Used to select the scene file previously set on the camera.
Note:
With [PRESET] selected, it results in the factory-adjusted setting.
? Mode select switch [MODE]
Used to select the camera color bar signal, test signal and camera picture signal. With the switch set to [BAR], [TEST], the color bar signal and the test signal are output from the monitor signal output terminal of this unit. With it set to [CAM], the picture taken by the camera is output.
@ Auto white start switch [AUTO WHITE]
With this switch pressed, the white balance is automatically adjusted. During the operation, WHTE LED blinks, and it goes out when the adjustment is normally finished. In case of NG, it lights up for a while and then goes out.
Note:
It does not operate when the mode is [BAR].
A Auto black start switch [AUTO BLACK]
With this switch pressed, the lens is automatically closed, and the black balance is adjusted. During the operation, BLACK LED blinks, and it goes out when the adjustment is normally finished. In case of NG, it lights up for a while and then goes out.
B R/B gain adjust volume [GAIN]
Used to adjust the R/B signal gain of the camera.
C R/B pedestal adjust volume [BLACK]
Used to adjust the R/B signal pedestal level of the camera.
D ND filter select switch [ND FILTER]
Used to select the optical filter (ND) of the camera.
E CC filter select switch [CC FILTER]
Used to select the optical filter (CC) of the camera.
Page 8
8
F Gain select switch [GAIN]
Used to select the master gain of the camera. It changes in the order of 0dB )9dB )18dB )S1 (Super gain 1) )S2 )3dB )0dB.
Note:
For super gain setting, check with the camera menu.
G Shutter select switch [SHUTTER OFF/STEP/SYNCHRO]
Used to select the electronic shutter of STEP and SYNCHRO set on the camera.
Note:
For electronic shutter setting, check with the camera menu.
H Indication change switch [CHECK]
Used to change the indication item.
I Indicator
It indicates the F value of iris.
J Master pedestal adjust volume [M-PED]
Used to adjust the pedestal setting of Y (luminance) signal of the camera.
K Lens iris auto/manual select switch [IRIS AUTO]
Used to select the lens iris adjusting method. With the switch set to [AUTO], the lens is shifted to auto iris mode, and the iris is automatically adjusted according to the amount of light coming into the lens. With the switch set to [MANU], the lens iris can be moved in the range from close to open by turning the lens iris adjust VR (volume) L. When storing the lens iris in the preset position select switch 8 by using the preset memory switch 7, set to [MANU] mode. It does not work in [AUTO] mode.
L Iris adjust volume [IRIS]
When the lens iris auto/manual select switch K is set at [MANU], the lens iris can be moved in the range from close to open. When the lens iris auto/manual select switch K is set at [MANU], press the preset position select switch 8 to call the preset memory, then the lens iris position is set to the preset memory position irrespective of the VR (volume) position. After that, when the VR is turned, the lens iris returns to the value of VR.
Controls and their Functions
Page 9
9
Pin No
8
9 10 11 12 13 14 15
Signal Y signal output Pb signal output Pr signal output Sync signal input DC 12V Frame GND TXD (H)
Signal Y signal GND Pb signal GND Pr signal output Sync signal GND DC GND TXD (C) RXD (H) RXD (C)
Pin No
1 2 3 4 5 6 7
CAMERA I / F
MONITOR OUT G/L IN TALLY IN
BREAKER
DC 12V IN
YPb Pr
P/T CONT
MN O P Q R S

_Rear panel

17
234
56
8
9101112131415
TXD: Data from camera to remote controller. RXD: Data from remote controller to camera.
N Swivel stand control signal input connector [P/T CONT (RJ-45)]
Connects the swivel stand control signal output of the pan-tilt control panel (AW­RP301).
O Monitor signal output connector [Y/G, Pb/B, Pr/R] (BNCk3)
Outputs the analog signal from the camera. The output can be changed to R, G, B/Y, Pb, Pr by the camera menu setting.
P Synch signal input connector [G/L IN] (BNCk1)
Inputs the sync signal to the camera. Input 3-value SYNC as the synch signal.
Q Tally signal input connector [TALLY IN] (2-pin connector block)
Connected to the tally connector from the system. When the HOT connector is at GND level, the tally LED is lighted.
Controls and their Functions
M Camera connector [CAMERA I/F]
Connected to the camera (AK-HC900P) with the attached cable.
Page 10
10
R Breaker [BREAKER]
DC power breaker. The breaker operates to cut off the power in case of over-current.
S DC12V input connector [DC12V IN] (XLR4-pin)
Connects the AC adapter. We recommend that the AW-PS505P (option) is used.
1
2
3
4
Controls and their Functions
Pin No
1
2, 3
4
Signal
GND
–––
12V
Page 11
11
ZOOM
REVERSE
FOCUS
REVERSE
NOR REV NOR REV
TU

_Front panel

T Zoom operation lever direction change switch [ZOOM REVERSE]
Used to change the direction of the zoom operation lever. With this switch set at [NOR], when the zoom operation lever : is shifted to [TELE], the zoom operates in a telescopic mode, and when shifted to [WIDE], zooming is made in a wide angle mode. With this switch set to [REV], it can be operated in the opposite direction. Also, with this switch set to [REV], the operating direction does not match the indication on the panel. In that case, use the attached seal for proper indication.
U Focus adjust direction change switch [FOCUS REVERSE]
Used to change the direction of the focus adjust lever. With this switch at [NOR], when the focus adjust lever ; is shifted to [FAR], the focus is adjusted to a far distance, and when shifted to [NEAR], the focus is adjusted to a near distance. With this switch set to [REV], focusing can be made in the opposite direction. Also, with this switch set to [REV], the operating direction does not match the indication on the panel. In that case, use the attached seal for proper indication.
Controls and their Functions
Page 12
12
Make the connection with power supply to the unit turned off.
Use AW-PS505P (option) as the AC adapter for control panel.Use a swivel stand, AW-PH300A, AW-PH500, AW-PH600, and an adapter suited for
the swivel stand.
When no swivel stand is used, connect both of the motor-driven zoom lens iris control
cable and remote (zoom/focus) cable to the camera. (see page 13)
When a swivel stand is used, connect the iris control cable to the camera, and the
remote (zoom/focus) cable to the swivel stand. (see the illustration below)
For the connection system of each unit, refer to pages 14 to 16.
BREAKER
ZOOM/ FOCUS
SDI OUT
1
2
1
/
F
G/LI N Pb OUT Pr / SDI
OUT
Y/VIDEO
OUT
1394
CONTROL IN
IP/RP
DC12V
IN
CAMERA I/F
LENSE I/F
ND/EXT
SDI
IN
CSOP

How to Connect

To iris connector
Iris control cable
Remote (zoom/focus control) cable
To lens interface connector
Connect the motor-driven zoom
lens iris control cable to the camera, and the remote (zoom/focus control) cable to the swivel stand. If the motor-driven zoom lens remote (zoom/focus control) cable is connected to the camera, the lens cannot be controlled.
Page 13
13

_Lens connection in the case of no swivel stand

_How to mount the lens
A lens of any maker’s can be used provided that it is a bayonet type (B4 mount) lens
of 2/3 inch standard.*
1 Turn the lens fixing ring knob counterclockwise and remove the lens mount cap. 2 Mount the lens and completely secure it by turning the lens fixing ring knob
clockwise.
3 Connect the iris control cable to the lens connector. 4 Connect the remote (zoom/focus control) cable to the zoom/focus connector on the
rear panel.
*Note that some lenses are uncontrollable with respect to zoom and focus function.
How to Connect
BREAKER
ZOOM/ FOCUS
SDI OUT
1
2
1
/
F
720
PROGRESSIVE
Iris control cable (to lens connector)
Remote (zoom/focus control) cable (Connect the cable to the swivel stand when used.)
Lens fixing ring knob
Page 14
14
O I
BREAKER
ZOOM/ FOCUS
SDI OUT
1
2
1
/
F
POWER
ON OFF
SD CARD
OPERATE
ALARM
SCENE
MODE
PRE
CAM BAR TEST
USER1 USER2
Camera Controller
TALLY
MENU
ON
MENU
SPEED ZOOM
TELE
WIDE
FAR
NEAR
FOCUS
12345
PRESET
CC FLTER
3200
CROSS
63004300
ND FLTER
11/321/161/4
SHUTTER
OFF
SYNCRO
STEP
GAIN
0
S1 S2
S3
9dB 18dB
AUTO
WHITE BLACK
GAIN
BLACK
AUTO
M-PED
IRIS
CHECK
Multi-cable (17ft) AK-HDMLTCA05
Camera controller
AK-HRP900P
D-SUB 15-pin
D-SUB 15-pin
HD monitor
AC adapter
AW-PS505P
Ext. sync signal (3-value SYNC)
DC power cable
Coaxial cable (5C-FB)HD-SDI
Remote control spec. lens
Remote (zoom/focus control) cable

Multi-purpose digital camera control system configuration 1

Multi-purpose digital
camera
AK-HC900P
Page 15
15

Multi-purpose digital camera control system configuration 2

Swivel stand
AW-PH300A
Multi-purpose digital camera AK-HC900P
Multi-cable (17ft) AK-HDMLTCA05
Camera controller
AK-HRP900P
HD monitor
AC adapter
AW-PS505P
Ext. sync signal (3-value SYNC)
DC power cable
Coaxial cable (5C-FB)HD-SDI
Remote (zoom/focus control) cable
AC adapter
AW-PS301
AC adapter
AW-PS505P
Swivel stand controller
AW-RP301
Swivel stand control is possible for AW­PH500/PH600 as well.
Remote control spec. lens
Remote (zoom/focus control) cable
BREAKER
ZOOM/ FOCUS
1
SDI OUT
2
/
F
1
O I
ND/EXT
IN
SDI
LENSE I/F
CAMERA I/F
DC12V
CONTROL IN
IN
1394
IP/RP
CSOP
G/LI N Pb OUT Pr / SDI
Y/VIDEO
OUT
OUT
O I
ON OFF
POWER
SD CARD
TALLY
MENU
ON
MENU
PRESET
12345
SPEED ZOOM
TELE
FAR
WIDE
NEAR
Camera Controller
SCENE
OPERATE
ALARM
PRE
USER1 USER2
MODE
AUTO
CAM BAR TEST
WHITE BLACK
GAIN
BLACK
CC FLTER
ND FLTER
3200
CROSS
63004300
11/321/161/4
SHUTTER
GAIN
OFF
SYNCRO
STEP
0
9dB 18dB
S1 S2
FOCUS
S3
CHECK
IRIS
M-PED
AUTO
Page 16
16

Multi-purpose digital camera control system configuration 3

O I
BREAKER
ZOOM/ FOCUS
SDI OUT
1
2
1
/
F
G/LI N Pb OUT Pr / SDI
OUT
Y/VIDEO
OUT
1394
CONTROL IN
IP/RP
DC12V
IN
CAMERA I/F
LENSE I/F
ND/EXT
SDI
IN
CSOP
O I
O I
POWER
ON OFF
SD CARD
OPERATE
ALARM
SCENE
MODE
PRE
CAM BAR TEST
USER1 USER2
Camera Controller
TALLY
MENU
ON
MENU
SPEED ZOOM
TELE
WIDE
FAR
NEAR
FOCUS
12345
PRESET
CC FLTER
3200
CROSS
63004300
ND FLTER
11/321/161/4
SHUTTER
OFF
SYNCRO
STEP
GAIN
0
S1 S2
S3
9dB 18dB
AUTO
WHITE BLACK
GAIN
BLACK
AUTO
M-PED
IRIS
CHECK
Swivel stand
AW-PH300A
Multi-purpose digital camera
AK-HC900P
Multi-cable (17ft) AK-HDMLTCA05
Camera controller
AK-HRP900P
HD monitor
AC adapter
AW-PS505P
DC power cable
Coaxial cable (5C-FB)HD-SDI
Remote (zoom/focus control) cable
AC adapter
AW-PS301
AC adapter
AW-PS505P
Swivel stand controller
AW-RP301
Swivel stand control is possible for AW­PH500/PH600 as well.
AC adapter
AW-PS300
Multi-cable (1.7ft) AK-HDMLTCA05
Interface adapter
AK-HTF900P
Trans-
mission
Remote control spec. lens
Page 17
17
The communication speed is factory-adjusted to 38.4Kpbs. In case it does not match the communication speed of multi-purpose camera AK-HC900P, the alarm LED is lighted. Remove the rear panel and change the DIP SW on the board and adjust it to the communication speed of the camera.
SW3
ON
1234
ON
1234
ON
1234
ON
1234
5678
Change the communication report by the combination of SW3 No.1 and No.2 on ROP CPU board.
125Kbit/Sec
38.4Kbit/Sec
9600Kbit/Sec
SW5 SW4SW3
Remove the screw and open the bottom plate, then DIP SW can be seen in there.

Communication Speed Setting

Page 18
18

_How to rack-mount

Install the main body on the rack as shown below.
Remove the rack mount bracket screw when installing
Rack mount bracket
Attached screw
Coupler
Coupler fitting holes

Example of Rack Mount

Page 19
CAMERA I / F
MONITOR OUT G/L IN TALLY IN
BREAKER
DC 12V IN
YPb Pr
P/T CONT
CAMERA I / F
MONITOR OUT G/L IN TALLY IN
BREAKER
DC 12V IN
YPb Pr
P/T CONT
19

_How to change the rear panel position

1 Remove the three screws on the
bottom to remove the blank panel.
* When installing, take care so that the internal wires are not caught by the panel.
3 Install the rear panel on the bottom with
the three screws.
ScrewScrew
Screw
Blank panel
Blank panel
Example of Rack Mount
Screw
2 Remove the three screws on the rear
panel to remove the rear panel.
4 Install the blank panel on the rear side
with the three screws.
Page 20
20

Appearance and Dimensions

( ): mm
ZOOM
REVERSE
FOCUS
REVERSE
NOR REV NOR REV
CAMERA I / F
MONITOR OUT G/L IN TALLY IN
BREAKER
DC 12V IN
YPb Pr
P/T CONT
POWER
ON OFF
SD CARD
OPERATE
ALARM
SCENE
MODE
PRE
CAM BAR TEST
USER1 USER2
Camera Controller
TALLY
MENU
ON
MENU
SPEED ZOOM
TELE
WIDE
FAR
NEAR
FOCUS
12345
PRESET
CC FLTER
3200
CROSS
63004300
ND FLTER
11/321/161/4
SHUTTER
OFF
SYNCRO
STEP
GAIN
0
S1 S2
S3
9dB 18dB
AUTO
WHITE BLACK
GAIN
BLACK
AUTO
M-PED
IRIS
CHECK
8-5/16z (210)
6-15/16z (176) 5/8z
(14.5)
2-1/4z (57)
5/8z
(15)
Page 21
21
Swivel stand control input: System tally input: Switch function:
Adjusting function:
Connection cable: Cable max. extension distance: Operating temperature range: Dimensions:
Weight: Finish:
Control signal (RJ-45 8P modular jack) Tally signal (2P connector block) Power control, preset memory, preset position select, speed polarity change, menu ON/OFF, menu operation, operation panel active, scene file select, mode select, auto white start, auto black start, ND filter select, CC filter select, gain select, shutter select, lens iris auto/manual select, indication change, zoom operation lever direction change, focus adjust direction change. Iris (lens iris), zoom, focus, R/B gain, master pedestal, R/B pedestal Multi-cable 1 pc 33 ft (10m) 32oF to 104oF (0oC to +40oC) 8-5/16(W)k3-1/2(H)k6-15/16(D) inch (210k88k176 mm) Approx. 3.3 lbs (1.5kg) AV ivory coating (Munsell 7.9Y 6.8/0.8 approx. color)
1is the safety information.
Power supply: DC +12V (XLR 4-pin connector) Power consumption: 5 W (camera controller only)

Specifications

Weight and dimensions shown are approximate. Specifications are subject to change without notice.
Page 22
22
Memo
Page 23
23
Memo
Page 24
Printed in Japan VQT0A79
PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY
UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA
Executive Office:
One Panasonic Way 4E-7, Secaucus, NJ 07094 (201)348-7000
EASTERN ZONE
One Panasonic Way 4E-7, Secaucus, NJ 07094 (201)348-7621
Southeast Region:
1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835
Central Region:
1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200
WESTERN ZONE:
3330 Cahuenga Blvd W., Los Angeles, CA 90068 (323) 436-3500
Government Marketing Department:
52 West Gude Drive, Rockville, MD 20850 (301) 738-3840
Broadcast PARTS INFORMATION & ORDERING:
9:00 a.m. – 5:00 p.m. (EST) (800) 334-4881/24 Hr. Fax (800) 334-4880 Emergency after hour parts orders (800) 334-4881
TECHNICAL SUPPORT:
Emergency 24 Hour Service (800) 222-0741
Panasonic Canada Inc.
5770 Ambler Drive, Mississauga, Ontario L4W 2T3 (905) 624-5010
Panasonic de Mexico S.A. de C.V.
Av angel Urraza Num. 1209 Col. de Valle 03100 Mexico, D.F. (52) 1 951 2127
Panasonic Sales Company Division of Matsushita Electric of Puerto Rico Inc.
San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630 (787) 750-4300
F0902H
@
3
Loading...