The following symbols appear on the product . its labeli ng, or the product packing.
Each symbol carries a speci al defi niti on, as defi ned below
V~ AC Voltage source
Dangerous : High Voltage.
Consult accompan ying documents .
Indicates protective earth gr ound.
┃Switch Power ON
OSwitch Power OFF
Medical Equipment is in accordance with
UL60601-1/CAN/CSA C22. 2 No.601.1 in r egard to electric
shock, fire hazards, and mechanical hazard.
Laser caution label.
General Specification
3
Safety Instructions
Warning
External equipment intended for connection to signal input, signal output or
other connectors, shall comply with relevant IEC standard(e.g.,IEC60950 for IT
equipment and IE C60601 series for medical electrical equipment).
In addition, all such combination-system-shall comply with the standard IEC
60601-1-1, safety requirement s for medical electrical system s. Any person who
connectors has f orm ed at system and is therefore responsible for the system
to comply with the requirements of IEC 60601-1-1.
if, in doubt, contact qualified t echnician or your local representative.
WARNING : To avoid the risk of electric shock, this equipment must only be
connected to a supply mains with protective earth.
WARNING : Appliance inlet shall be used for mains disconnection.
- Do not dismantle the housing or modify the product.
Dismantling the housing or modifying the product may result in electrical shock
or burn.
- Refer all servicing to qualified service personnel .
Do not attempt to service this product yourself as opening or removing
housing may expose you to dangerous voltage or other hazards.
- Keep the product away from liquids.
Spilling into the housing may result in fire, electrical s hock, or equipment
damage. If an object or liquid falls/spills into the housing, unplug the product
imm ediately . Have the product checked by a qualified service engineer before
using it again.
- Do not touch the Product with wet hands.
Touching the housing and plug with wet hands is dangerous and can cause
electrical shock.
- Do not to touch signal input, signal output or other connectors,
and the patient simultaneou sly.
General Specification
4
Caution
General Specification
5
EEC Safety Compl iance:
This display unit m eets the r equirem ents of EN-60601-1 so as to
conform to the M edi cal Devi ce D i r ect i ve 93/42/ EEC (general safety
information).
This moni tor compl ies to the above standards only when used wit h the supplied
medical gr ade power s upply. R PS-160 S er ies ( Mean well)
Caution:
Make sur e the power cord i s the correct type t hat is requir ed in your area.
This DMS-H1616 has a universal power supply that al lows operation in either
100-120V AC or 200-240V AC voltage areas (no user adjustment i s required).
Use the proper pow er cord w ith corr ect attachment plug type. If the power source
is 120 V AC , use a pow er c or d w hi ch i s a Hos pit al Grade Power Cor d w i th N EMA
5-15 style plug, l abeled for 125 volts AC with UL and C-UL approvals . If the power
source i s a 240 V AC supply, use the tandem ( T blade) type attachm ent pl ug with
ground c onductor power cord that meets the r especti ve European country's safety
regulations.
The hospital-gr ade plug for m edical products intended for use i n Denmark has
DEMKO approv al and i s rated 13 amps at 250Vac. Plug is recommended for use
in medical applicati ons and speci fications are being added to the standard SB
107-2-D1. Plug mates wi th m ak er 's D ani sh hos pit al-grade socket . Hospi tal sock ets
have sli ghtly different s haped openi ngs al low ing only the hospital pl ug, not the
standard Dani sh plug, to be inser ted, to protect t he ac circui t in specific m edical
settings.
General Specification
6
Servicing
Do not attempt to service the apparatus y ourself as opening or removing covers
may expose you to dangerous voltages or other hazards, and will void the
warranty . Refer all servicing to qualified service personnel.
Unplug the apparatus from its power source and refer servicing to qualified
personnel under the following conditions:
- If the power cord or plug is damaged or frayed.
- If liquid has been spilled into the apparatus.
- If objects have fallen into the apparatus.
- If the apparatus has been exposed to rain or m oisture.
- If the apparatus has been subjected to exc essive shock by being dropped.
- If the cabinet has been damaged.
- If the apparatus seems to be overheated.
- If the apparatus emits smoke or abnormal odor.
- If the apparatus fails to operate in accordance with the operating
instructions.
Accessories
Use only accessories specified by the manufacturer, or sold with the apparatus.
Classification
- Protection against electric shock : Class I
-Applied Parts : No Applied Parts
- Degree of safety in the presence of flamm able anesthetics mixture with air or
with oxygen or w ith nitrous oxide.
Not suitable for use in the presence of a flammable anesthetics mixture with
oxygen or with nitrous oxide.
- Mode of operation : Continuous.
General Specification
7
Cleaning and Maintenance
This product needs to be check and clean every one month as below;
▪ Make sure the fan is operating normally.
If the fan does not operate normally, serious problems will occur such as overheating.
Cleaning
Turn off the power.
1.
2. Separate each card from the body.
3. Clean with dry cloth inside of the body after each card is separated.
4. Remove foreign substance on t he surface of each card w ith air gun.
5. Install each car back to the body .
6. Clean w ith dry cloth outside of the body.
General Specification
8
FCC Information
This equipment has been tested and f ound to c omply with the limits of a Class A
digital devic e, pur s uant t o Part 15 of the FCC rules.
These lim i ts are designed to pr ovide reasonab l e p r otec ti on ag ai ns t i nter ference.
This monitor can radiat e r adio frequenc y energ y and, i f not installed and used i n
accordance with the instructions, it may interfere with other radio communications
equipment. There is no guarantee that i nter ference w i l l not occur in a partic ul ar
installation.
If this equipment is found to cause harmful interference to radio or television
reception, the user is encouraged to try to correct the interference by carrying out
one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the dist ance between the color monitor and the sub jec t of
interference.
3. Plug the monitor into a outlet on a different electrical circuit than \that to which
the subject of interference is connected.
4.Consult the dealer or an exp er i enced r adi o/ TV t echni c i an for help.
NOTICES TO USER :
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired op er ati on.
FCC WARNING :
This equipement geneates or uses radio f r eq uenc y energy. C hang es or
modifications to this equipement may cause harmful interference unl ess the
modifications are expres sl y app r oved in the instructi on manual. The user coul d
lose authority to operate this equipment if an unauthorized change or modification
is made.
Class AThe model DMS-H1616 uses R F energy only for
its internal function Therefore. Its RF emissions are
very low and are not lik el y to cause any i nter ference
in nearby electronic equipment
General Specification
9
1. Overview
1.1 Scope
The DMS-H1616 Matrix Switcher shall be a new matrix switcher systems designed to satisfy the
needs of small scale installations. Also, DMS-H1616 Matrix Switcher is an integrated product which
has a number of independent DVI and optical switch, which has easy field configuration modular
(which is a truly modular) frame.
The DMS-H1616 is specially designed for switching up to 16-input DVI signals to up to 16 output
destinations (16 input DVI signal allows switching up to 16 output signals). Fiber solution is used for
long distance transmission (the max. distance 300m at WUXGA (1920x1200).
This multi-mode 1 fiber cable makes it possible to use DVI transmission and compatibility with our
DSL products. Using the RS232 port for control of external equipment, and intuitive control for WEB
control is possible. In addition, the w eb is to upgrade the Firmware.
1.2 Revision History
DateParagraphChange Description
09.07.271.0Preliminary release
General Specification
10
2.1 General Des cript ion
ItemDescription
ModelDMS-H1616
2. General Features
Input Signal
Output Signal
Power Supply
Control
Classification- Protection against electric shock : Class I
Unit Dime nsion
16 x DVI (DMS-CARD-CI)
16 x Optical DVI (DMS-CARD-FI)
16 x DVI (DMS-CARD-CO)
16 x Optical DVI (DMS-CARD-FO)