Omron M3W User Manual

Manufacturer
EU-representative
Production facility Site de production Herstellungswerk Stabilimento di produzione
Subsidiary
Succursale Niederlassung Consociata
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com
Planta de producción Productiefaciliteit
Производственное подразделение
Empresa filial Dochteronderneming Филиал
OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD.
Binh Duong Province, VIETNAM
OMRON HEALTHCARE UK LTD.
Opal Drive Fox Milne, Milton Keynes, MK15 0DG, U.K.
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a, 68163 Mannheim, GERMANY www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE
Uniquement pour le marché français:
OMRON Service Après Vente N° Vert 0 800 91 43 14 consommateurs@omron-sante.fr www.omron-sante.fr/contact
Digital Automatic Blood Pressure Monitor
Instruction Manual
English Français Deutsch Italiano Español Nederlands Русский
IM-HEM-7202-E(V)-02-01/2012
5334060-6B
Check following components!
Vérifier les composants suivants ! Prüfen Sie folgende Teile des Lieferumfangs! Controllare i componenti indicati di seguito! ¡Compruebe los siguientes componentes!
Eng
lis
h
Français
D
Deu
ig
ital A
tsc h
ut
om
a t
ic B
Italia
lo
o d
no
P r
ess
u re
M
Moni
o
d
Esp
el
to
M
r
3W
o l
I n
s
t r u
ct
Ned
i o
erland
n
M
a n
s
u
a l
Рус
ский
IM
­H E
M
-7 2
02
-E (V )
-0
2
­0
1/ 20
12
5334060
-6 B
Controleer de volgende onderdelen! Проверьте следующие компоненты!
Contents
21
F
c
L
d
J
b
a
Thank you for purchasing the OMRON M3W Digital Automatic Blood Pressure Monitor. The OMRON M3W is a compact, fully automatic blood pressure monitor, operating on the
oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the devices uses its advanced “IntelliSense” technology.
Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated arm cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit.
Important Safety Information........................ 1
1. Overview ...................................................3
2. Preparation ...............................................4
2.1 Installing/Replacing the Batteries...........4
2.2 Setting the Buzzer/ Date and Time ........5
3. Using the Unit...........................................6
3.1 Applying the Arm Cuff ............................6
3.2 How to Sit Correctly ...............................7
3.3 Taking a Reading...................................8
3.4 Using the Memory Function .................12
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
4. Troubleshooting and Maintenance....... 14
4.1 The Icons and Error Messages ........... 14
4.2 Troubleshooting................................... 16
4.3 Maintenance........................................ 18
4.4 Storage................................................19
5. Optional Parts.........................................20
6. Technical Data ........................................21
7. Some Useful Information about Blood Pressure.... 24
F E
A
B
C
D
I J K
L
G
H
M
N O P Q
R S T
U
V
W X
Y Z AA
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit.
Warning:
• Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
(General Usage)
• Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous.
• People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause internal bleeding.
(AC Adapter Usage)
• Never plug in or unplug the power cord from the electric outlet with wet hands.
(Battery Usage)
• If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.
Caution:
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
EN
(General Usage)
• Do not leave the unit unattended with infants or persons who cannot express their consent.
• Do not use the unit for any purpose other than measuring blood pressure.
• Do not disassemble the unit or arm cuff.
• Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results.
• Make sure that the air tube is not wrapped around other parts of your body when taking measurements. This could result in injury when the air pressure in the air tube is increased.
• Do not leave the cuff wrapped on the arm if taking measurements during the night. This could result in injury.
• Do not inflate the arm cuff over 299 mmHg.
• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
• Do not operate the unit in a moving vehicle (car, airplane).
• To inflate the cuff manually, refer to Section 3.3. If the cuff is over inflated, it can cause internal bleeding.
1
Important Safety Information
(AC Adapter Usage)
• Use only the original AC adapter (optional) designed for this unit. Use of unsupported adapters may damage and/or may be hazardous to the unit.
• Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-tap.
• Do not use the AC adapter if the unit or the power cord is damaged. Turn off the power and unplug the power cord immediately.
(Battery Usage)
• If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
• Use only four “AA” alkaline or manganese batteries with this unit. Do not use other types of batteries.
• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace all four batteries at the same time.
• Remove the batteries if the unit will not be used for three months or more.
• Do not use new and used batteries together.
General Precautions
• Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
2
• Do not take measurements after bathing, drinking alcohol, smoking, exercising or eating.
• Do not forcibly bend the arm cuff or bend the air tube excessively.
• When removing the air tube, pull on the air plug at the connection with the main unit not the tube itself.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not wash the arm cuff or immerse it in water.
• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.
• Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts.
1.
Open the rear cover page to read following:
A
B
CDE
F
G
H
I
J
KLM
N
O
PQR
S
T
U
V
W
X
Y
Z
AA
Overview
The alphabet in the rear cover page correspond to those in the body page.
Main unit
Display O/I START ( ) button User A/B button Up/Down ( ) buttons Buzzer and Date/Time setting ( ) button Air Jack Battery compartment AC adapter jack (for optional AC adapter)
Arm cuff
Arm cuff (Wide Range Cuff: arm
Display
Systolic blood pressure Diastolic blood pressure Heartbeat symbol
(Flashes during measurement)
Average value symbol Deflation symbol Memory symbol Irregular heartbeat symbol Movement error symbol Blood pressure level indicator Pulse display and Memory
number Buzzer symbol
EN
circumference 22-42cm) Marker Air tube Air plug
Cuff wrapping guide USER ID symbol (A/B) Battery low symbol Date/Time display
3
2.
2.1
Preparation
Installing/Replacing the Batteries
1. Remove the battery cover.
2. Insert four “AA” batteries as
indicated in the battery compartment and then replace the battery cover.
Notes:
• If the battery low symbol ( ) appears on the display, turn the unit off then replace all batteries at the same time.
• The measurement values continue to be stored in memory even after the batteries are replaced.
4
Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries.
Loading...