Omron M3 INTELLISENSE User Manual

Digital Automatic Blood Pressure Monitor
Model M3 Intellisense
Instruction Manual
Mode d’emploi
Gebrauchsanweisung
Manuale di istruzioni
Manual de instrucciones
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
EN
FR
DE
IT
ES
NL
RU
IM-HEM-7051-E-02-08/08
1647554-2B
Contents
Contents....................................................................................2
Introduction ..............................................................................3
Important Safety Information ..................................................4
1. Overview ..............................................................................5
2. Preparation ..........................................................................8
2.1 Installing/Replacing the Batteries.....................................8
2.2 Setting the Date and Time .............................................10
2.3 Adjusting the Settings Modes ........................................13
3. Using the Unit....................................................................14
3.1 How to Sit Correctly When Taking a Measurement .......14
3.2 Applying the Arm Cuff ....................................................16
3.3 Taking a Reading...........................................................18
3.4 Instructions for special conditions ..................................22
3.5 Using the Memory Function ...........................................23
4. Quick Reference Guide.....................................................26
5. Handling Errors and Problems ........................................27
5.1 Error Messages..............................................................27
5.2 Troubleshooting .............................................................29
6. Maintenance and Storage.................................................31
7. Optional Parts....................................................................34
8. Technical Data...................................................................35
9. Some Useful Information about Blood Pressure ...........37
2
Introduction
Thank you for purchasing the OMRON M3 Intellisense Upper Arm Blood Pressure Monitor.
The OMRON M3 Intellisense is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need for pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.
The unit also stores up to 42 measurements in memory and calculates an average reading based on the three most recent measurements taken within 10 minutes of the last reading. (If there are only two readings in memory for that period, the average will be based on two readings. If there is only one reading in memory for that period, that reading will be displayed as the average value.)
Please read this instruction manual thoroughly before using the unit. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
EN
3
Important Safety Information
Consult your doctor during pregnancy, arrhythmia and arteriosclerosis.
You should never change the dosage of medication prescribed by your doctor.
Use the M3 Intellisense only for yourself.
Caution:
Do not leave the unit unattended with infants or persons who cannot express their consent.
Do not use the unit for any purpose other than measuring blood pressure.
Do not use a cellular phone near the unit. This may result in incorrect operation of the unit.
Do not operate unit in a moving vehicle (car, airplane).
Do not apply strong shocks and vibrations to or drop the main unit and arm cuff.
Please observe the following points.
-
Do not insert the batteries with their polarities incorrectly aligned.
-
Replace old batteries with new ones immediately.
-
When you are not going to use the unit for a long period of time (approximately three months or more), take out the batteries.
-
Do not use new and used batteries together.
-
Do not use batteries of a different type together.
-
Only use four Do not use other types of batteries.
-
When using batteries, the battery liquid may leak and damage the main unit.
Do not forcibly bend the arm cuff or bend the air tube excessively.
When removing the air tube, pull on the air plug at the connection with the main unit not the tube itself.
Do not inflate the arm cuff when it is not wrapped around your arm.
4
AA manganese or alkaline batteries with this unit.
1.
Overview
Main unit
1.Overview
A
E
D
B
C
F
G
A. Display B. O/I START button C. MEMORY button D. SET button
E. Battery compartment F. Ai r jac k G. AC adapter jack (for optional
AC adapter)
EN
5
1.Overview
Arm Cuff
If air starts to leak from the arm cuff, please replace with a new one. (Refer to Chapter 7 “Optional Parts”.)
IH
J
H. Arm cuff
(Medium cuff: arm circumference 22-32 cm) I. Air Tube J. Air Plug
6
Display
K
L M
O P
K. Systolic blood pressure L. Diastolic blood pressure M. Memory symbol
(Displayed when viewing values stored in memory)
N. Average value symbol
(Displayed when viewing value for the last three
measurements) O. Buzzer symbol P. Battery low symbol
Package contents
1.Overview
N
Q. Heartbeat symbol
R. Pulse display S. Deflation symbol T. Date/Time display U. Irregular heartbeat symbol
Q
R
S
T
U
1.(Flashes during measurement)
2.(If flashing after measurement complete indicates blood pressure out of recommended range)
EN
V. Storage case W. Four “AA” alkaline (LR6)
batteries
WV
• Instruction manual
• Guarantee card
• Blood pressure pass
• Blood Pressure Monitor unit
7
2.Preparation
2.
Preparation
2.1
Installing/Replacing the Batteries
1.
Turn the main unit upside down.
2.
Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover.
3.
Install or replace four AA size batteries so that the + (positive) and - (negative) polarities match the polarities indicated on the battery compartment.
4.
Put the battery cover back in place.
Slide the battery cover as indicated, until it clicks into place.
Note:
The measurement values continue to be stored in memory even after the batteries are replaced.
8
2.Preparation
Battery Life & Replacement
If the battery low symbol ( ) appears on the display, replace all four batteries at the same time.
-
When the battery low symbol ( ) starts to blink, you will still be able to use the unit for a short while. You should replace the batteries with new ones ahead of time.
-
When the symbol ( ) remains lit, the batteries are exhausted. You should replace the batteries with new ones at once.Turn the unit off before replacing the batteries.
Remove the batteries if the unit will not be used for three months or more.
If the batteries have been removed for more than 30 seconds, the Date/Time setting will need to be reset. See “2.2 Setting the Date and Time” for details.
Dispose of batteries according to applicable local regulations.
Four new
AA alkaline batteries will last for approximately
1500 measurements, when used to take two measurements a day.
Since the supplied batteries are for monitoring use only, they may have a shorter life and not last for 1500 measurements.
EN
9
2.Preparation
2.2
Setting the Date and Time
Your blood pressure monitor automatically stores up to 42 measurements values in its memory and calculates an average value based on the three most recent measurements taken within 10 minutes of the last reading. (If there are only two readings in memory for that period, the average will be based on two readings. If there is only one reading in memory for that period, that reading will be displayed as the average value.) To make use of the memory and average values functions:
Set the unit to the correct date and time before taking a measurement for the first time.
If the batteries have been removed for more than 30 seconds, the Date/Time setting will need to be reset.
1.
When the O/I START button is pressed to turn the unit on for the first time after inserting batteries, the year digits (2005) will flash on the display.
2.
Press the MEMORY button to advance the digits one at a time.
10
Notes:
The range for the year setting is 2005 to 2030. If the year reaches 2030, it will return to 2005.
If you hold down the MEMORY button, the digits will advance rapidly.
3.
Press the SET button to confirm the setting when the desired number appears on the display.
The year is set and the month digits flash on the display.
4.
Repeat steps 2 and 3 to set the month.
The month is set and the day digits flash on the display.
5.
Repeat steps 2 and 3 to set the day.
The day is set and the hour digits flash on the display.
2.Preparation
EN
11
2.Preparation
6.
7.
Repeat steps 2 and 3 to set the hour.
The hour is set and the minutes digits flash on the display.
Repeat steps 2 and 3 to set the minutes.
The minutes settings is set. The unit automatically turns
itself off after the minute setting has been set.
To adjust the date and time, press the Set button while the monitor is in standby mode.
12
Loading...