Omron K3NP-NB1A, K3NP-NB2A, K3NP-PB1A, K3NP-PB2A, K3NP-NB1C User Manual

...
Period Meter K3NP B-193
Timers
Period Meter
K3NP
An Ideal Interface for Easily Measuring the Time Interval
• 50-kHz input range and 0.08% accuracy for sophisticated control.
• A wide selection of outputs: relay, transistor, BCD, linear, or communications.
• Maximum/Minimum value hold, set value write protection, and more.
• Banks with four comparative output values and four prescale values.
• Set value teaching, linear output range teaching, and prescale teaching are available using actual measured values.
• Prescale function available, which displays in units of actual physical parameters (length, volume, etc.).
• Displays values in hours, minutes, and seconds in operating modes 2 to 4.
• Built-in sensor power supply (12 VDC, 80 mA).
• Compact 1/8 DIN size.
• Conforms to EMC standards, EN61010-1 (IEC1010-1).
• UL/CSA approved.
®
Model Number Structure
Model Number Legend
Base Units and Output Boards can be ordered individually or as sets. Refer to the Output Board Combinations table on page 194.
1, 2. Input Sensors Codes
NB: NPN inputs/Voltage pulse inputs PB: PNP inputs
3. Supply Voltage
1: 100 to 240 VAC 2: 12 to 24 VDC
4. Display
A: Basic C: Set Value LED Display
5, 6, 7, 8. Output Type Codes
C1: 3 comparative relay contact outputs (H, PASS, L: SPDT) C2: 5 comparative relay contact outputs (HH, H, L, LL: SPST-
NO; PASS: SPDT)
C5: 5 comparative relay contact outputs (HH, H, L, LL: SPST-
NC; PASS: SPDT) T1: 5 comparative transistor outputs (NPN open collector) T2: 5 comparative transistor outputs (PNP open collector) B2: BCD output (NPN open collector) (see note) B4: BCD output + 5 transistor outputs (NPN open collector) L1: Linear output (4 to 20 mA) (see note)
L2: Linear output (1 to 5 VDC) (see note) L3: Linear output (1 mV/10 digits) (see note) L4: Linear output, 4 to 20 mA + 5 transistor outputs (NPN open
collector)
L5: Linear output, 1 to 5 V + 5 transistor outputs (NPN open col-
lector)
L6: Linear output, 1 mV/10 digits+ 5 transistor outputs (NPN
open collector) L7: Linear output, 0 to 5 VDC (see note) L8: Linear output, 0 to 10 VDC (see note) L9: Linear output, 0 to 5 VDC + 5 transistor outputs (NPN open
collector) L10: Linear output, 0 to 10 VDC + 5 transistor outputs (NPN open
collector) FLK1: Communication RS-232C (see note) FLK2: Communication RS-485 (see note) FLK3: Communication RS-422 (see note) FLK4: RS-232C + 5 transistor outputs (NPN open collector) FLK5: RS-485 + 5 transistor outputs (NPN open collector) FLK6: RS-422 + 5 transistor outputs (NPN open collector)
Note: These output types are available on Basic Models only.
1234
1
2345678
5 678
K3NP -
Base Units
K3NP - -
Base Units with Output Boards
K31 -
Output Boards
B-194 Period Meter K3NP
Ordering Information
Base Unit
Available Output Board Combinations
Note: For details, refer to the Communication Operation Manual.
Input type NPN/Voltage pulse PNP
Supply voltage 100 to 240 VAC 12 to 24 VDC 100 to 240 VAC 12 to 24 VDC
K3NP-NB1A K3NP-NB2A K3NP-PB1A K3NP-PB2A
K3NP-NB1C K3NP-NB2C K3NP-PB1C K3NP-PB2C
Output type Output configuration Output boards Base units
Basic Set Value
LED Display
Relay contact 3 outputs: H, PASS, L (SPDT) K31-C1 Yes Yes
5 outputs: HH, H, L, LL (SPST-NO), and PASS (SPDT) K31-C2 Yes Yes 5 outputs: HH, H, L, LL (SPST-NC), and PASS (SPDT) K31-C5 Yes Yes
Transistor 5 outputs (NPN open collector) K31-T1 Yes Yes
5 outputs (PNP open collector) K31-T2 Yes Yes
BCD (see note) 5-digit output (NPN open collector) K31-B2 Yes --- Linear 4 to 20 mA DC K31-L1 Yes ---
1 to 5 VDC K31-L2 Yes --­1 mV/10 digits K31-L3 Yes --­0 to 5 VDC K31-L7 Yes --­0 to 10 VDC K31-L8 Yes ---
Communication boards (see note)
RS-232C K31-FLK1 Yes --­RS-485 K31-FLK2 Yes --­RS-422 K31-FLK3 Yes ---
Combination output and communication boards
BCD output + 5 transistor outputs (NPN open collector) K31-B4 Yes Yes 4 to 20 mA + 5 transistor outputs (NPN open collector) K31-L4 Yes Yes 1 to 5 V + 5 transistor outputs (NPN open collector) K31-L5 Yes Yes 1 mV/10 digits + 5 transistor outputs (NPN open collector) K31-L6 Yes Yes 0 to 5 VDC + 5 transistor outputs (NPN open collector) K31-L9 Yes Yes 0 to 10 VDC + 5 transistor outputs (NPN open collector) K31-L10 Yes Yes RS-232C + 5 transistor outputs (NPN open collector) K31-FLK4 Yes Yes RS-485 + 5 transistor outputs (NPN open collector) K31-FLK5 Yes Yes RS-422 + 5 transistor outputs (NPN open collector) K31-FLK6 Yes Yes
Basic Models
These models provide a present value LED and front-panel control keys. Can be connected to any Output Board, or can be used for display only without an Output Board.
Set Value LED Models
These models provide a present value LED, set value LED, and front-panel control keys. Can be connected to Relay, Transistor, or Combination Output Boards.
Period Meter K3NP B-195
Timers
Specifications
Ratings
Note: A K3NP with DC supply voltage requires approximately 1 A DC as control power supply current the moment the K3NP is turned ON. Do not
forget to take this into consideration when using several K3NP units. When the K3NP is not in measuring operation (e.g., the K3NP has been just turned ON or is operating for startup compensation time), the display will read “00000” and all outputs will be OFF.
Supply voltage 100 to 240 VAC (50/60 Hz); 12 to 24 VDC Operating voltage range 85% to 110% of supply voltage Power consumption (see note) 15 VA max. (max. AC load with all indicators lit)
10 W max. (max. DC load with all indicators lit)
Sensor power supply 80 mA at 12 VDC±10% Insulation resistance 20 M min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Dielectric strength 2,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Noise immunity ±1,500 V on power supply terminals in normal or common mode ±1 µs, 100 ns for square-wave noise
with 1 ns
Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 0.75-mm for 2 hrs each in X, Y, and Z directions
Shock resistance
Malfunction: 98 m/s
2
(10G) for 3 times each in X, Y, and Z directions
Destruction: 294 m/s
2
(30G) for 3 times each in X, Y, and Z directions
Ambient temperature Operating: 10°C to 55°C (with no icing)
Storage: 20°C to 65°C (with no icing)
Ambient humidity Operating: 25% to 85% (with no condensation) EMC (EMI) EN61326+A1 Industry
Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/-2 Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/-2 (EMS) EN61326+A1 Industry Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3) Immunity Fast Transient Noise: EN61000-4-4: 2 kV (power line) (level 3) Immunity Burst Noise: 1 kV line to line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kV line to line
2 kV line to ground (power line) Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180°, 100% (rated voltage)
Approved standards UL508, CSA22.2;
Conforms to EN61326+A1, EN61010-1 (IEC61010-1) Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted.
Weight Approx. 400 g
B-196 Period Meter K3NP
Characteristics
Note: The linear output range cannot be set when connected to a 1 mV/10-digit Linear Output Board.
Input signal No-voltage contact (30 Hz max., ON/OFF pulse width: 15 ms min.)
Voltage pulse (50 kHz max., ON/OFF pulse width: 9 µs min., ON voltage: 4.5 to 30 V/OFF voltage: 30 to 2 V) Open collector (50 kHz max., ON/OFF pulse width: 9 µs min.)
Connectable Sensors
ON residual voltage: 3 V max. OFF leakage current: 1.5 mA max. Load current: Must have switching capacity of 20 mA min.
Must be able to dependably switch a load current of 5 mA max.
Measuring accuracy (at 23±5°C)
±0.08%rdg±1 digit
Measuring modes and ranges
Operating mode 1: Passing speed 10 ms to 3,200 seconds Operating mode 2: Cycle 20 ms to 3,200 seconds Operating mode 3: Time difference 10 ms to 3,200 seconds Operating mode 4: Elapsed time 10 ms to 3,200 seconds Operating mode 5: Length measurement 0 to 4G count (32-bit counter) Operating mode 6: Interval 0 to 4G count (32-bit counter)
Max. displayed digits 5 digits (0 to 99999) Display 7-segment LED Polarity display Not available Zero display Leading zeros are not displayed. Prescale function
Programming via front-panel key inputs. (0.0001 x 10
9
to 9.9999 x 109, decimal point can be set freely)
Can be set using prescale value teaching.
HOLD functions Max. value (peak) hold, Min. value (bottom) hold External control HOLD (Process value held)
RESET (Maximum/minimum data reset) BANK (Selection of one bank out of 4 banks of set values)
(Selection of one bank out of 4 banks of prescale values)
Other functions Variable linear output range (for models with linear outputs only) (see note)
Remote/Local processing (available for communications output models only) Maximum/Minimum value data reset with front panel keys Comparative output pattern selection Time unit display Security
Output configuration Relay contact output (3 or 5 outputs)
Transistor output (NPN and PNP open collector), BCD (NPN open collector) Parallel BCD (NPN open collector) + transistor output (NPN open collector) Linear output (4 to 20 mA, 1 to 5 V) + transistor output (NPN open collector) Communication functions (RS-232C, RS-485, RS-422) Communication functions (RS-232C, RS-485, RS-422) + transistor output (NPN open collector)
Delay in comparative outputs (at transistor output)
20 ms max.
Linear output response time 40 ms max. Degree of protection Front panel: NEMA4 for indoor use (equivalent to IP66)
Rear case: IEC standard IP20 Terminals: IEC standard IP00
Memory protection Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)
Period Meter K3NP B-197
Timers
Input/Output Ratings
Relay Contact Output
(Incorporating a G6B Relay)
Transistor Output
BCD Output
Note: Logic method: negative logic
Linear Output
Note: For the 1 mV/10-digit output, the output voltage changes for every 40 to 50 increment in the display value.
Communications Specifications
For details, refer to Communication Operation Manual.
Item Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Rated load 5 A at 250 VAC; 5 A at 30 VDC 1.5 A at 250 VAC, 1.5 A at 30 VDC Rated carry current 5 A max. (at COM terminal) Max. contact voltage 380 VAC, 125 VDC Max. contact current 5 A max. (at COM terminal) Max. switching capacity 1,250 VA, 150 W 375 VA, 80 W Min. permissible load
(P level, reference value)
10 mA at 5 VDC
Mechanical life 50,000,000 times min. (at a switching frequency of 18,000 times/hr) Electrical life
(at an ambient temperature of 23°C)
100,000 times min. (at a rated load switching frequency of 1,800 times/hr)
Rated load voltage
12 to 24 VDC
+10%
/
–15%
Max. load current 50 mA Leakage current 100 µA max.
I/O signal name Item Rating
Inputs REQUEST, HOLD, MAX, MIN, RESET Input signal No-voltage contact input
Input current with no-voltage input 10 mA Signal level ON voltage: 1.5 V max.
OFF voltage: 3 V min.
Outputs DATA, POLARITY, OVERFLOW,
DATA VALID, RUN
Rated load voltage
12 to 24 VDC
+10%
/
15%
Max. load current 10 mA Leakage current 100 µA max.
Item 4 to 20 mA 1 to 5 V 1 mV/10 digits (see note) Resolution 4,096 Output error ±0.5% FS ±1.5% FS Permissible load resistance 600 max. 500 min. 1 K min.
Item RS-232C, RS-422 RS-485 Transmission method 4-wire, half-duplex 2-wire, half-duplex Synchronization method Start-stop synchronization Baud rate 1,200/2,400/4,800/9,600/19,200/38,400 bps Transmission code ASCII (7-bit) Communications Write Comparative set value, prescaling value, remote/local programming, reset control of maximum/mini-
mum values, and other setting mode items excluding communications conditions.
Read Process value, comparative set value, maximum value, minimum value, model data, error code, and
others
B-198 Period Meter K3NP
Connections
Terminal Arrangement
Input Unit
18 19 20 21 22 23 24 25 26
10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9
Terminal Numbers
Output unit
Input unit
Output unit
Input unit
Note: Terminals 7 to 13 are connected internally.
Terminals 7 and 11 are mutually isolated.
Signal input terminal
12 VDC 80 mA
When inputting the external control signals through the open collector:
Transistor Inputs: ON: Residual voltage must be 3 V max. OFF: Leakage current must be 1.5 mA max. The switching capacity must be 20 mA or greater.
When the external signal input is short-circuited, a voltage of approximately 5 V will be applied to between the terminals 5 to 7 and the COM terminal, and a current of approximately 18 mA (nominal value) will flow.
100 to 240 VAC or 12 to 24 VDC
Note: Check the power supply specifications of the
model used before connecting the power supply. Recommended 24VDC power supply; eg. OMRON S8VS
+12 V
+12 V
590
590
820
820
+12 V
10
1
2
11
GND
GND
+12 V
590
820
3
GND
10 k
+12 V
590
820
4
11
GND
10 k
+12 V
+12 V
590
820
10
1
2
11
GND
GND
GND
590
820
External sensor power supply (+)
Input A
Input B
External sensor power supply ()
Internal circuits
Voltage Pulse Inputs
Input A
Input B
Internal circuits
PNP-input Models
External sensor power supply (+)
Input A
Input B
External sensor power supply ()
Internal circuits
NPN Inputs
10 1 1
1234
+12 V
INA INB
0 V
10 11
1234
INA INB GND
10 11
1234
+12V
INA INB
0 V
+12V
INA INB
0 V
10 11
1234
Contact
NPN output sensor
PNP output sensor
Contact Output Voltage Output PNP Open Collector OutputNPN Open Collector Output
(NPN Linear 2-wire Output)
Note: Connect the + side of the NPN
linear 2-wire input to terminal 1 and the side to terminal 11.
Note: With voltage pulse input
not from a 3-wire sensor, connect the + side to ter­minal 3 and the side to terminal 11.
Note: When the contact is short-
circuited, a current of approxi­mately 13 mA will flow at a volt­age of approximately 12 V.
Input resistance: 10 k
Voltage pulse output sensor
Period Meter K3NP B-199
Timers
Output Units
18 19 20 21 22 23 24 25 26
18 19 20 21 22 23 24 25 26
18 19 20 21 22 23 24 25 26
18 19 20 21 22 23 24 25 26
K31-C1: Relay (3 Outputs)
Outputs (5 A max. at 250 VAC)
H PASS L
K31-C2: Relay (5 Outputs)
Outputs (5 A max. at 250 VAC)
K31-C5: Relay (5 Outputs)
Outputs (5 A max. at 250 VAC)
HH PASS L
LLH
HH PASS L
H
LL
K31-T1: Transistor (NPN Open Collector)
Outputs (50 mA max. at 24 VDC)
HH H PASS L LL COM
+
18 19 20 21 22 23 24 25 26
18 19 20 21 22 23 24 25 26
10
0
10
1
10
2
10310
4
48
10
4
12 4812 48 12 48 12 48 12
20
1 2 3 4 5 6 7 8 9 10111213141516171819
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
K31-T2: Transistor (PNP Open Collector)
Outputs (50 mA max. at 24 VDC)
HH H PASS L LL COM
K31-B2, -B4: BCD (NPN Open Collector)
(Terminals 32 to 36 are provided only on K31-B4.)
Outputs (50 mA max. at 24 VDC)
HH H PASS L LL COM
COMMON
DATA OVERFLOW
DATA VALID
RUN
COMMON
REQUEST
MAX. REQ.
MIN. REQ.
HOLD
RESET
POLARITYHHH
PASSLLL
COMMON
K31-L1, L2, L3,-L4, -L5, -L6, -L7, -L8, -L9,
-L10: Linear
(Terminals 21 to 26 are provided only on K31-L4,
-L5, -L6, -L9, -L10.)
L1, L4: 4 to 20 mA L2, L5: 1 to 5 V L3, L6: 1 mV/10 digit L7, L9: 0 to 5 VDC L8, L10: 0 to 10 VDC
Note: With K31-L4/-L5/-L6/-L9/-L10 models, terminals 19
and 26 are connected internally.
SD
RD
SG
14
12345678910111213
15 16 17 18 19 20 21 22 23 24 25
K31-FLK1: RS-232C
+
18 19 20 21 22 23 24 25 26
RDA
SDA
RDB
SDB
SG
RS-422
6
2345
789
6
12345
789
1
K31-FLK2, -FLK5: RS-485
(Terminals 21 to 26 are provided only on K31-FLK5.)
HH H PASS L LL COM
RS-485
Terminator
ON
OFF
Outputs (50 mA max. at 24 VDC)
K31-FLK3, -FLK6: RS-422
(The right connector is provided only on K31-FLK6)
ON
OFF
K31-FLK4: RS-232C + Transistor (NPN Open Collector)
RS-232C
LL
HH
L
COM
H
PASS
Terminator
RS-422
D-sub 37P Connectors for BCD output (attachment)
Plug: XM2A-3701 Hood: XM2S-3711
D-sub 25P connectors for RS-232C output (K31-FLK1) (order
separately) Plug: XM2A-2501 Hood: XM2S-2511
D-sub 9P connectors for RS-422 output (K31-FLK3 and K31-
FLK6) (order separately) Plug: XM2A-0901 Hood: XM2S-0911
D-sub 9P connectors for RS-232C output (K31-FLK4) (order
separately) Plug: XM2D-0901 Hood: XM2D-0911
Output NPN Tr. (50 mA max. at 24 VDC)
Output NPN Tr. (50 mA max. at 24 VDC)
L
H
PASS
HH
9
4321
87
6
5
LL
RD
SD
SG
COM
9
4321
87
6
5
B-200 Period Meter K3NP
Block Diagram
Input circuit
Sensor A
Sensor B
GND
Control input
LED
Frequency measurement circuit Waveform adjustment circuit
8-bit microcomputer
Control input circuit
Power supply for sensor
Control input circuit
Control power supply
Power supply circuit
Frequency measurement circuit
Wavefo rm adjustment circuit
Voltage stabilizing circuit
Voltage stabilizing circuit
Voltage stabilizing circuit
Key switch
8-bit microcomputer
Output circuit
Power supply for sensor (input circuit)