Miniature Relay for Signal Circuits
■ Wide switching power of 10 µA to 2 A.
■ High dielectric strength coil-contacts:1,000 VAC;
open contacts: 750 VAC.
■ Conforms to FCC Part 68 requirements.
■ Ag + Au clad bifurcated crossbar contacts and
fully sealed for high contact reliability.
■ New 150-mW relays with high-sensitivity.
G5V-2 PCB Relay
RC
Ordering Information
Classification Contact form Contact type Contact material Enclosure ratings Model
Standard DPDT Bifurcated crossbar Ag + Au-clad Fully sealed G5V-2
High-sensitivity G5V-2-H1
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 12 VDC
Rated coil voltage
Model Number Legend
G5V - - VDC
132
1. Contact Form
2: DPDT
2. Classification
H1: High-sensitivity
3. Rated Coil Voltage
3, 5, 6, 9, 12, 24, 48 VDC
Specifications
■ Coil Ratings
Standard Models
FCC
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 166.7 mA 100 mA 83.3 mA 55.6 mA 41.7 mA 20.8 mA 12 mA
Coil resistance 18
Coil inductance
(H) (ref. value)
Must operate voltage 75% max. of rated voltage
Must release voltage 5% min. of rated voltage
Max. voltage 120% of rated voltage at 23°C
Power consumption Approx. 500 mW Approx.
Armature OFF 0.04 0.09 0.16 0.31 0.47 1.98 7.23
Armature ON 0.05 0.11 0.19 0.49 0.74 2.63 10.00
W
50
W
72
W
162
W
288
W
1,152
W
4,000
580 mW
1
W
G5V -2G5V-2
High Sensitivity Models
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 8.33 mA 6.25 mA
Coil resistance 60
Coil inductance
(H) (ref. value)
Must operate voltage 75% max. of rated voltage
Must release voltage 5% min. of rated voltage
Max. voltage 180% of rated voltage at 23°C 150% of rated
Power consumption Approx. 150 mW Approx.
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Contact Ratings
■
Load Resistive load (cos
Rated load 0.5 A at 125 VAC; 2 A at 30 VDC 0.5 A at 125 VAC; 1 A at 24 VDC
Contact material Ag + Au-clad
Rated carry current 2 A
Max. switching voltage 125 VAC, 125 VDC
Max. switching current 2 A 1 A
Max. switching power 62.5 VA, 60 W 62.5 VA, 24 W
Failure rate (reference value) 0.01 mA at 10 mVDC
Note Note:P level: l60 = 0.1 x 10–6/operation
■
Characteristics
Armature ON 0.18 0.46 0.70 1.67 2.90 6.72 20.1
Armature OFF 0.57 0.71 0.97 2.33 3.99 9.27 26.7
Item Standard models High sensitivity models
W
166.7
W
240
f
= 1)
W
540
W
960
W
2,880
200 mW
W
7,680
W
voltage at
23°C
Approx.
300 mW
Item Standard models High sensitivity models
Contact resistance 50 m
Operate time 7 ms max.
Release time 3 ms max.
Bounce time Operate: approx. 0.3 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Insulation resistance 1,000 M
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil
Impulse withstand voltage 1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Endurance Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Ambient temperature Operating:
Ambient humidity Operating: 5% to 85%
Weight Approx. 5 g
W
max. 100 mW max.
Release: approx. 1.5 ms
Electrical: 1,800 operations/hr (under rated load)
W
min. (at 500 VDC)
and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 200 m/s
Electrical: 100,000 operations min. (at 1,800 operations/hr)
-
25°C to 65°C (with no icing) Operating: -25°C to 70°C (with no icing)
2
(approx. 100G)
2
(approx. 20G)
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts
of same polarity
2
Destruction: 1,000 m/s
Malfunction: 100 m/s
(approx. 100G)
2
(approx. 10G)
2