Omron Gentle Temp 720 User Manual

0 (0)
English
Français
Deutsch
Italiano
Español
Nederlands

Türkçe
0186342-2B
Infrared
Forehead Thermometer
Model Gentle Temp 720
Instruction Manual
It is mainly designed for household use.
Contents
Thank you for purchasing the OMRON Gentle Temp 720 Infrared Forehead Thermometer.
Intended Use:
The OMRON Gentle Temp 720 offers safe, comfortable, and quick temperature measurement from the
forehead.
Important Safety Information .....................................1
1. Overview .................................................................3
2. Preparation .............................................................4
2.1 Removing the Insulating Tape ......................4
2.2 Switching between °C and °F ....................... 4
2.3 Setting the Buzzer
........................................ 5
3. Using the Unit .........................................................6
3.1 Taking a Reading .........................................6
3.2 Using the Memory Function ........
...............10
4. Troubleshooting and Maintenance ....................11
4.1 The Icons and Error Messages .................. 11
4.2 Questions and Answers ............................. 13
4.3 Maintenance .............................................. 14
4.4 Replacing the Battery ................................. 15
5. Technical Data ...................................................... 16
6. Some Useful Information .................................... 19
Please read this instruction manual thoroughly before using this unit.
Please keep for future reference. For specific information about your own temperature,
CONSULT YOUR DOCTOR.
1
EN
Important Safety Information
To assure correct use of the product, basic safety measures should always be followed, including the precautions listed
below.
Warning: The following situations are potentially hazardous and, if not avoided, could result in death or serious
injury.
Conducting self-diagnosis based on the measurement results and/or treatment can be dangerous. Please follow the
instructions of your doctor. Self-diagnosis may worsen the symptoms.
A high or prolonged fever requires medical attention, especially for small children. Please contact your doctor.
Keep the unit out of children's reach.
If a child swallows the battery, immediately consult with a doctor.
Do not throw batteries into a fire. The battery may explode.
Remove the battery when the unit will not be used for three months or more. Failure to do so may lead to fluid leakage,
heat generation or bursting, resulting in damage to the unit.
Do not use the unit to measure any item with a temperature higher than 80.0°C (176.0°F).
General Precautions
Do not apply a strong shock to, drop, step on, or vibrate the main unit.
Do not use a mobile phone near the unit.
The main unit is not waterproof. Be careful when handling this unit so that no liquid (alcohol, water, or hot water) will get
into the main unit. When the unit is wet with vapor, wait until it dries or wipe it lightly with a soft dry cloth.
Do not disassemble, repair, or modify the unit.
When the probe lens becomes dirty, wipe it lightly with a soft dry cloth or a cotton swab. Do not wipe the probe lens with
tissue paper or a paper towel.
If there is any temperature difference between the places where the unit is stored and where you are going to measure,
leave the unit in the room where you are going to use it for more than 30 minutes to allow it to reach room temperature first,
then measure.
2
Important Safety Information
If the forehead is cold, wait until the forehead is warmed up before taking a temperature measurement. The measured result may
indicate low when you use an ice bag or an ice pack, or immediately after coming in from the outside in winter.
Do not use the unit when wet after swimming, bathing, or through sweating after physical exercise, as skin temperature
may have fallen. Wipe away moisture and allow 30 minutes for the body to acclimatize to room temperature before
measuring.
Do not touch the probe lens with a finger or breathe on it.
Do not attempt measurements when the unit is wet as inaccurate readings may result.
Check the icon on the display before and after the measurement so that the measurement is taken in the appropriate
mode.
When taking the temperature of an object with low emissivity such as gold or aluminum, inaccurate readings may result.
When taking the temperature of something with low emissivity (such as milk) in surface measurement mode, slightly lower
readings may result.
Do not use the unit in places where strong static electricity or electromagnetic fields are present. Doing so may lead to
inaccurate readings and may contribute to instrument failure.
When you inform your doctor of your temperature, make sure you state that you measured the temperature from the
forehead.
3
EN
1. Overview
Surface temperature
Room temperature
Last reading
Battery icon
Mute icon
Temperature mode (°F)
Memory icon
Temperature mode (°C)
Forehead
temperature
Main unit: Display:
Probe lens
Battery
compartment
Probe lens cap
Display
ON/MEM button
START button
4
2. Preparation
2.1
Removing the Insulating Tape
When using the thermometer for the first time, pull the
insulating tape out of the battery compartment.
The unit is turned on and after 1 minute the room temperature
appears on the display.
Notes:
The room temperature remains on the display even after the unit turns off.
Place the unit on a level surface, in a place that is at room temperature (away from direct sunlight or air conditioning, etc.).
2.2
Switching between °C and °F
This unit is set in °C as default.
1.
While the room temperature is displayed, press and hold the START button.
2.
While holding it down, press and hold the ON/MEM
button until °F appears on the display with two beeps.
Notes:
To select °C mode again, start from step1.
When the unit is switched between °C and °F, all the readings stored in the
memory are deleted.
Back of the unit
2. Preparation
5
EN
2.3
Setting the Buzzer
The buzzer is activated by default, but can be deactivated.
Note: The buzzer is only available in forehead measurement mode.
1. Press the ON/MEM button to turn on the unit.
2. Press and hold the ON/MEM button for 3 seconds.
The “ ” icon flashes on the display.
3. Release the ON/MEM button.
The “ ” icon remains lit and the buzzer is deactivated.
Notes:
If the ON/MEM button is pressed down for more than 5 seconds after the “ ” icon starts
flashing, the unit turns off without deactivating the buzzer.
To activate the buzzer again, start from step1.
6
3. Using the Unit
3.1
Taking a Reading
Forehead Measurement Mode
This mode displays the oral-equivalent value of the measured forehead temperature.
Always make sure the probe lens is clean and undamaged, and the forehead is clean with no sweat, cosmetics,
scars, etc.
Prior to measurement, ensure that the patient has not taken a bath or exercised within the last 30 minutes, and
has remained in a stable environment for at least 5 minutes.
It is recommended to perform measurement three times. If the three measurements are different, select the
highest temperature.
1. Pull off the probe lens cap to remove it.
2. Press the ON/MEM button.
All indicators appear on the display for 1 second.
Then the display shown on the far right appears with two beeps.
Loading...
+ 16 hidden pages