Temperature Controller E5CS-X
DIN-sized (48 48 mm) Temperature
Controller Features Automatic P
(proportional action) Tuning Function
Accurate to ±0.5% of full scale.
Multiple temperature ranges allow easy selection
for application.
Field-selectable temperature ranges in °C and °F.
Easy-to-read, 11-mm high LED digital display.
Tamper-proof setting, faulty-sensor detection, and
controller diagnostics.
8-function alarm available.
Nonvolatile memory.
Field-selectable control mode (ON/OFF or PID).
Ordering Information
Thermocouple Type
Standard temperature ranges
(switch selectable)
T
emperature unit (selectable)
Measurement unit
Control mode
Without alarm
With alarm
Relay output
V
Relay output
V
oltage output
oltage output
Input
1,000
900
800
700
600
500
400
300
200
100
Set no.
K (CA) Chromel-alumel
600
999
………
………
………
………
………
………
………
………
………
………
………
0
0
1
………
………
………
………
………
………
………
………
………
………
300
………
………
………
………
0
………
………
………
………
………
400
………
………
………
………
………
0
………
………
………
………
………
………
………
200
………
………
………
0
0
0 1 2 3 4 5 6 6 7 8 9
°C °C °C/°F °C/°F °C/°F °C/°F °F °C °C °C/°F °C/°F
ON/OFF or PID
E5CS-RKJX
E5CS-QKJX
E5CS-R1KJX
E5CS-Q1KJX
………
………
………
………
500
………
………
………
………
………
………
0
………
………
………
………
………
………
………
………
………
………
………
J (IC) Iron-constantan
999
………
………
………
………
………
………
………
………
………
………
………
………
………
………
………
………
………
………
………
200
………
………
………
0
0
………
………
………
………
………
………
………
300
………
………
………
………
0
………
………
………
………
………
………
400
………
………
………
………
………
0
………
………
………
………
………
500
………
………
………
………
………
………
0
1
E5CS-X
Platinum Resistance Thermometer Type
Input
500
400
300
200
Standard temperature ranges
(switch selectable)
T
emperature unit (selectable)
Measurement unit
Control mode
Without alarm
With alarm
Thermistor Type
Standard temperature ranges
(switch selectable)
T
emperature unit (selectable)
Measurement unit
Control mode
Without alarm
With alarm
Relay output
V
Relay output
V
Relay output
V
oltage output
Relay output
V
oltage output
oltage output
oltage output
Input
500
400
300
200
100
–100
Set no.
100
–100
Set no.
…………
…………
…………
…………
50
…………
…………
0
…………
–50
0 1 2 3 4 5 6 7 8 9
ON/OFF or PID
E5CS-RGX
E5CS-QGX
E5CS-R1GX
E5CS-Q1GX
Platinum resistance thermometer (Pt: 100 Ω, JIS and DIN standard types)
…………
…………
…………
…………
…………
…………
0
…………
50
–50
………
………
………
………
50.0
………
………
0.0
………
………
………
………
………
80
………
………
………
–20
………
………
………
………
99.9
………
………
0.0
………
………
………
………
200
………
………
………
0
………
………
………
300
………
………
………
………
0
………
………
400
………
………
………
………
………
0
………
………
………
………
………
………
………
0
………
0 1 2 3 4 5 6 7 8
°C °C °C/°F °C/°F °C/°F °C °C °C/°F °C/°F
1 0.1 1 0.1 1
ON/OFF or PID
E5CS-RPX
E5CS-QPX
E5CS-R1PX
E5CS-Q1PX
THE element interchangeable thermistor
………
………
………
………
………
………
………
100
………
………
………
………
………
………
0
………
150
50
………
………
………
200
………
………
100
………
………
………
………
300
………
………
………
150
………
………
………
………
………
………
100
………
………
………
–50
………
………
………
200
………
………
………
0
………
………
………
300
………
………
………
100
………
………
………
400
………
………
………
200
………
………
………
°C °F
1
E5CS-X
…………
600
…………
…………
…………
…………
…………
0
…………
…………
…………
…………
300
…………
…………
…………
…………
800
600
The
functions can be factory-set for shipment as shown in the table below
place
your order
. T
wo suf
fixes are selectable: “-DIN” or “-F”.
, depending on the suf
fix attached to the model number when you
Example: E5CS-RKJX-DIN
Suffix
Suffix
Standard temperature
range
T
emperature unit (selectable)
K(CA)/J(IC)
PT
THE
2 (0 to 400) 8 (0 to 400) 2 (0 to 400)
3 (0.0 to 99.9) 3 (0.0 to 99.9) 3 (0.0 to 99.9)
1 (–50 to 50) 1 (–50 to 50) 1 (–50 to 50)
°C °C °F
None -DIN -F
Control mode ON/OFF ON/OFF ON/OFF
Proportional period
Relay output
V
oltage output
Control output
Input shift
T
emperature sensor standard
Alarm mode
The
functions can be factory-set
switch.
For details on the DIP switch settings, refer to
in accordance with your needs. The above settings, however
20 s
20 s
20 s
2 s
Reverse operation Reverse operation Reverse operation
Cannot be set Cannot be set Cannot be set
JIS (ISO) DIN JIS (ISO)
2 (upper-limit) 2 (upper-limit) 2 (upper-limit)
, can be easily changed using the internal DIP
Function Setting
.
2
E5CS-X
Accessories (Order Separately)
Protective Cover Y92A-48
The
protective cover protects the
section, against dust, dirt, and water drip. It also prevents the set
values
from being altered due to accidental contact with the
keys.
Y92A-48
Protective Cover
front panel, particularly the setting
setting
E5CS-X
3
E5CS-X
Specifications
Ratings
Supply
voltage
Operating voltage range
Power consumption
Control output
Alarm output
Characteristics
Setting
accuracy
Indication accuracy
Hysteresis
Proportional band
Reset time
Rate time
Alarm output setting range
Alarm output setting range
(Absolute-value alarm mode)
Proportional period
Sampling period
Insulation resistance
Dielectric strength
V
ibration resistance
Shock resistance
Ambient temperature
Humidity
Degree of protection
Life expectancy
Weight
Relay
Voltage
E5CS-X
100 to 240 V
85 to 1
Approx. 7 V
3 A 250 V
20 mA 12 VDC, w/short-circuit protection circuit
1 A 250 V
±
0.5% of full scale, ±1 digit max.
Set value coincides with indicated value, since no relative error exists between these values.
0.2% of full scale (during ON/OFF control)
3% to 20% (automatically adjusted according to the rise time of the controlled system)
4 minutes (fixed)
0.4 minutes (fixed)
0 to full scale for all modes except the absolute-value alarm mode (see note)
Same as switch-selectable standard temperature ranges shown at the top of the tables in
Ordering Information
2/20 seconds
500 ms (Output change period: 2 seconds; Indication change period: 2 seconds)
20 MΩ min. (at 500 VDC)
2,000 V
AC, 50/60 Hz for 1 minute (between current-carrying terminals of dif
Malfunction: 2 to 55 Hz, 2 G for 10 minutes each in X, Y
Destruction: 10 to 55 Hz, 0.75 mm double amplitude for 2 hours each in X, Y
Malfunction: 100 m/s2, in 6 directions, 3 times each
Destruction: 300 m/s2, in 6 directions, 3 times each
Operating: –10 to 55
Storage: –25 to 65
35% to 85% RH
IEC 144
Front panel: IP50
Rear panel: IP30
T
erminals: IP00
Mechanical: 10,000,000 operations min. (relay output)
Electrical: 100,000 operations min. (relay output)
Approx. 170 g (main enclosure only)
AC 50/60 Hz
10% of rated supply voltage
A
AC (resistive load), SPDT
AC (resistive load), SPST-NO
ferent polarity)
, and Z directions
, and Z directions
°C
°C
Note: Set
values must be within the allowable range limits for alarm values, control outputs, etc. If a set value does not satisfy the following
condition,
Minimum of temperature range x T
where:
T
X=Alarm value.
select another range:
=Set temperature, and
set
±X x Maximum
set
of temperature range
4