Sequence input signal- Multi-function input x 8 by parameter setting (forward/reverse drive prohibition, emergency stop, external latch,
Sequence output signalIt is possible to output three types of signal form incl.: brake release, servo ready, servo alarm, positioning com-
I/O signal
USB
communications
MECHATROLINKII communications
Automatic load inertia detectionAutomatic motor parameter setting. One parameter rigidity setting.
Dynamic brake (DB)Built-in. Operates during main power OFF, servo alarm, servo OFF or overtravel.
Regenerative processingInternal resistor included in models from 600 W to 5 kW. Regenerative resistor externally mounted (option).
Overtravel (OT) prevention functionDB stop, deceleration stop or coast to stop during P-OT, N-OT operation
Encoder divider functionOptional division possible
Protective functionsOvercurrent, overvoltage, undervoltage, overspeed, overload, encoder error, overheat...
Analog monitor functions for supervisionAnalog monitor of motor speed, speed reference, torque reference, command following error, analog input...
Integrated functions
Panel operatorDisplay functions2-digit 7-segment LED display shows the drive status, alarm codes, parameters...
CHARGE lampLits when the main circuit power supply is turned ON.
Safety terminalFunctionsSafety Torque OFF function to cut off the motor current and stop the motor. Output signal for failure monitoring
External encoder feedbackSerial signal and line-driver A-B-Z encoder for full-close control
Speed zero clampPreset velocity command can be clamped to zero by the speed zero clamp input.
soft start time setting0 to 10 s (acceleration, deceleration can be set separately).
communication
InterfacePersonal computer/ Connector mini-USB
Communications standardCompliant with USB 2.0 standard
FunctionParameter setting and status monitoring
Communications protocolMECHATROLINK-II
Station address41H to 51 FH (max. number of slaves: 30)
Tranmission speed10 Mbps
Transmission cycle1, 2 & 4 ms
Data length32 bytes
Switches2 x rotary switches for setting the MECHATROLINK-II node address
Position signal outputA-phase, B.phase, Z-phase line driver output and Z-phase open-collector output.
Sequence input signal- Multi-function input x 10 by parameter setting (servo ON, control mode switching, forward/reverse drive prohi-
I/O signal
Sequence output signalIt is possible to output four types of signal form incl.: brake release, servo ready, servo alarm, positioning com-
Speed zero clampPreset velocity command can be clamped to zero by the speed zero clamp input.
Soft start time setting0 to 10 s (acceleration, deceleration can be set separately). S-curve acceleration/deceleration is also available.
Torque limit3 VDC at rated torque (torque can be limited separately in positive/negative direction).
Preset speed controlPreset speed is selectable from 8 internal settings by digital inputs.
Speed limitSpeed limit can be set by parameter.
Input pulse typeSign + pulse train, 90° phase displacement 2-phase pulse (A-phase+ B-phase) or CCW/CW pulse train
Input pulse frequency4 Mpps max. (200 Kpps max. at open collector).
Command pulse scaling
- Dedicated input x 1 (SEN: sensor ON, ABS data request).
plete, motor rotation speed detection, torque limit detection, zero speed detection, speed coincidence detection,
warning, position command status, speed limit detection, speed command status.
30
can be set for numerator (encoder resolution) and denominator (command pulse resolution
30
can be set for numerator (encoder resolution) and denominator (command pulse resolution).
30
can be set for numerator (encoder resolution) and denominator (external encoder resolution
64AC servo systems
USB
Communications
InterfacePersonal computer/ Connector mini-USB
Communications standardCompliant with USB 2.0 standard
FunctionParameter setting and status monitoring
Automatic load inertia detectionAutomatic motor parameter setting. One parameter rigidity setting.
Dynamic brake (DB)Built-in. Operates during main power OFF, servo alarm, servo OFF or overtravel.
Regenerative processingInternal resistor included in models from 600 W to 5 kW. Regenerative resistor externally mounted (option).
Overtravel (OT) prevention functionDB stop, deceleration stop or coast to stop during P-OT, N-OT operation
Encoder divider functionOptional division possible
Electronic gearing (Numerator/Denominator)Up to 4 electronic gear numerators by combining with inputs.
Internal speed setting function8 speeds may be set internally
Protective functionsOvercurrent, overvoltage, undervoltage, overspeed, overload, encoder error, overheat...
Analog monitor functions for supervisionAnalog monitor of motor speed, speed reference, torque reference, command following error, analog input...
The monitoring signals to output and their scaling can be specified by parameters.
Number of channels: 2 (Output voltage: ±10V DC)
Panel operatorDisplay functions6-digit 7-segment LED display shows the drive status, alarm codes, parameters...
Integrated functions
Panel operator keysUsed to set/monitor parameters and drive condition (5 key switches).
CHARGE lampLits when the main circuit power supply is turned ON.
Safety terminalFunctionsSafety torque OFF function to cut off the motor current and stop the motor. Output signal for failure monitoring
EN61508:2001 (Safety Integrity Level 2, SIL2), EN954-1:1996 (CAT3).
External encoder feedbackSerial signal and line-driver A-B-Z encoder for full-close control
Expansion connectorSerial bus for option board
Note: the above pictures show 230 V servo drives models only. The 400 V servo drives have 24 VDC power input terminals for control circuit
instead of L1C and L2C terminals.
Accurax G5 servo drive65
I/O specifications
Terminals specifications (for all drives)
SymbolNameFunction
L1Main power supply input terminalAC power input terminals for the main circuit
L2
L3
L1CControl power supply input terminalAC power input terminals for the control circuit
L2C
24 VDC power input terminals for the control circuit
0 V
B1External regeneration resistor connection terminals Servo drives below 750W: no internal resistor is connected. Leave B2 and B3 open.
B2
B3
UServo motor connection terminalsTerminals for outputs to the servomotor.
V
W
Note: for single-phase servo drives connect the power supply input to L1 and L3.
(for 200V single/three-phase servo drives only).
(for 400V three-phase servo drives only).
Connect an external regenerative resistor between B1 and B2.
Servo drives from 750W to 5 kW: short-circuit in B2 and B3 for internal regenerative resistor. If the
internal regenerative resistor is insufficient, connect an external regenerative resistor between B1 and
B2 and remove the wire between B2 and B3.
6I-COM± pole of external DC power. The power must use 12V-24V (±5%)
5E-STOPEmergency stop The signal name shows the factory setting. The function can be
7P-OTForward run prohibited
8N-OTReverse run prohibited
9DECOrigin proximity
10EXT3External latch input 3
11EXT2External latch input 2
12EXT1External latch input 1
13SI-MON0General purpose monitor input 0
14
15
17-Terminals not used. Do not connect.
18192021222324-
-PCLForward torque limitThe function of input signals allocated to pins 5 and 7 to 13 can be changed with these options by
ShellFGShield ground. Connected to frame ground if the shield wire of the I/O signal cable is connected to the connector shell.
16GNDSignal ground. It is insulated with power supply (I-COM) for the control signal in the servo drive.
1BRK-OFF+External brake release signal
2BRK-OFF
25S-RDY+Servo ready: ON when there is no servo alarm and control/main circuit power supply is ON
26S-RDY3ALM+Servo alarm: Turns OFF when an error is detected
4ALM-
-INP1Position complete output 1The function of output signals allocated to pins 1,2, 25 and 26 can be changed with these options by
AT-SPEEDSpeed complete
T_LIMTorque limit
ZSPZero speed
V-COINSpeed coincidence
INP2Position complete output 2
WARN1Warning 1
WARN2Warning 2
DENOrigin proximity
V_LIMSpeed limit
parameters settings
66AC servo systems