Omega Products CN76020 User Manual

Page 1
1
16 DIN Autotune Controller
KMTSS-125G-6 thermocouple sold separately, $24, see page A-81.
Panel punches
available, visit
omega.com/
panelpunches
Single Output
Model
$
Dual Output
$
494
CN76000 Series
Starts at
$
494
Dual 4-Digit DisplayAutotune PID, PID, or
On/Off Control
Thermocouple Input
with 1° or 0.1° Resolution
RTD Input with
Scalable Voltage and
Current Inputs
Displays in °F, °C, or
Engineering Units
Password Protection
Model
534
Front-Panel ProgrammingRelay, DC Pulse,
Optional Features
Analog Process or
Tracking/Non-Tracking
Additional Features
Loop Break ProtectionMin/Max IndicationAuto/Manual OperationPercent Output IndicationSingle-Segment Ramp
CN76030, $494, shown larger than actual size.
AC SSR, Voltage, or Current Output(s)
RS485 Digital Output
Alarms
and Soak
P-1
High
Performance
in a Small
Package!
Compact, 1⁄16 DIN Size, with NEMA 2, 3R, and 12 Rated Front Panel.
Page 2
CN76030, compact
1
16 DIN size, $494,
shown actual size.
Status LEDs indicate status of setpoint and alarm outputs.
°F/°C engineering units. Both indicators are off for non-temperature inputs.
INDEX key advances menu for programming. Also used with decrement key to reset an alarm programmed for manual reset.
Increment key raises value or turns “on” menu item chosen. Also used with ENTER key to display secondary and secure menus.
Convenient screw terminal connections.
Upper display continuously indicates process value or value of menu item selected.
Lower display continuously indicates set value or menu item selected.
ENTER key enters new settings or commands into memory. Also used with the increment key to display other menus.
Decrement key lowers value or turns “off” menu item chosen. Also used with INDEX key to reset an alarm programmed for manual reset.
The CN76000 1⁄16 DIN controllers provide economical control for a wide variety of processes, including heating, cooling, and heat/cool. When used with the proper transmitters, these devices can also control pressure, flow, humidity, motion, or pH. The front panel is NEMA 2, 3R, and 12 rated for waterproof protection and is corrosion resistant.
The sophisticated design of the CN76000 incorporates the latest microprocessor and surface mount technology, compressing an unprecedented number of standard features into a compact 1⁄16 DIN package. The user can program control functions from the front panel; input types are DIP switch selectable. Multiple tuning modes allow the user to select from 3 standard tuning presets, manual tuning, or autotuning.
P
Standard features include self-diagnosis with fault indication. Non-volatile memory retains all process parameters when power is off, without battery backup. Settings for the optional alarm are configurable. The alarm action may be defeated on startup, or until the process value exceeds the alarm setpoint. The power interrupt feature will reset on power-up if the alarm condition no longer exists.
Other standard features include min/max storage and display, auto/manual control, percent output indication, ramp and soak operation, 4 user-selectable security levels with password protection, and jumper-selected 5 Vdc pulse output to drive external solid state relays. Optional features include RS485 communications, process recorder output, and 4-stage setpoint.
P-2
Page 3
OF F
AL
OF F
OF F
OF F
ENTER INDEX
A1
A2
MADE IN US A
PV
SV
48
(1.880)
48
(1.880)
125 (4.925) 1 14 (4.475)
12
(0.450)
*3
(0.125)
45
(1.760)
Panel cutout for all models is 45 x 45 mm (1.775 x 1.775"). Allow for 13 mm (0.5") clearance at rear of instrument. * Present for all outputs other than relay.
12
11 61
2
V
mA
3
4
5 13 14 10
9
10
9
8
7 7
+
8
+
7
8
+
RTD
T/C
+
ALARM
(IF EQUIPPED)
1/4 A
3 AG 250 Vac
Line
85 to 265 Vac/Vdc
50 to 400 Hz
5 V max
* SOFTWARE CONFIGURABLE AS SP1 OR SP2
FOR OUTPUT RATINGS SEE SPECIFICATIONS.
SOLID STATE RELAY OR RELAY OUTPUT
5 Vdc LOGIC
OUTPUT
OUTPUT B*
SOLID STATE
RELAY OR RELAY OUTPUT
5 Vdc LOGIC OUTPUT
4 to 20 mA DC
or
0 to 10 Vdc
AUX
IN/OUT
OUTPUT A *
Specifications
Inputs: Thermocouple, RTD,
voltage or current; see input chart for ranges Resolution: See range chart; voltage and current input models are fully field scalable to engineering units with up to 2 decimal places
Accuracy: ±0.25% span ±1 digit Input Impedance: 3 M min,
thermocouple; 200 µA, RTD current; 249 , current; 5 k, voltage
Sensor Break Protection:
De-energizes control outputs to protect system
Loop Break Protection:
Error message is initiated on shorted sensor or open heater circuit; break time adjustable from off to 99 min. Loop Break Alarm: On alarm relay equipped units, unit can be programmed to alarm on loop break
Setpoint Range: Selectable Displays: Dual 4-digit, 7-segment
LED, 7.6 mm (0.3") high; process variable in red, setpoint in green Control Action: Reverse (heat) or direct (cool) action; selectable for single or dual setpoint models Control Modes: Time-proportioning and proportional control modes; selectable preset tune, autotune or manual PID, P, PI or PD with reset anti-windup Proportional Band: 6 to 5000°F or equivalent °C units; 6 to 9990 for voltage/current inputs
Integral Time:
0.1 to 99.9 minutes, or off
Derivative Time:
0.01 to 99.99 minutes, or off
Cycle Time: 2 to 80 s Approach Rate: Off to 99.99 min On-Off Control: Adjustable on-off
differential 2° to full scale in 1° steps, 2 counts to full scale in 1-count steps (voltage/current inputs) Ramp and Soak: One ramp time and soak time each adjustable from 0 to 100 hours; end procedure can be set for HOLD or OFF
Power:
85 to 265 Vdc or Vac, 50 to 400 Hz
Power Consumption: 5 VA max Line Voltage Stability:
±0.05% over supply voltage range
Temperature Stability:
4 µV/°C (2.3 µV/°F) typical, 8 µV/°C (4.5 µV/°F) max
Common-Mode Rejection:
140 dB minimum at 60 Hz
Normal-Mode Rejection:
65 dB typical, 60 dB at 60 Hz
External Wiring
Dimensions: mm (in)
Isolation: Relay and SSR outputs
are isolated; current, voltage and logic outputs must not share common grounds with the input
Memory:
Non-volatile; no batteries required Mechanical Relay Output: SPST (form A), 3 A @ 250 Vac, resistive;
1.5 A @ 250 Vac, inductive; 250 VA pilot duty rating, 2 A @ 125 Vac or 1 A @ 250 Vac,
1
8 hp @ 125 Vac or 250 Vac
Solid State Relay Output: 3.5 A up to 240 Vac at 25°C (77°F); derates to 1.25 A @ 55°C (131°F)
Voltage Output:
Non-isolated; 0 to 10 Vdc, 500 min Current Output: Non-isolated; 0 to 20 mA, 600 max; zero and span adjustable
DC Pulse Output:
Non-isolated; 5 Vdc @ 25 mA Operating Ambient: -10 to 55°C (-4 to 131°F); 0 to 90% RH up to 40°C (104°F), non-condensing; 10 to 50% at 55°C (131°F), non-condensing
P-3
Storage Ambient:
-40 to 80°C (-40 to 175°F) Alarms: 2 alarms operate the same relay; 3.0 A resistive 250 Vac; form A contact (SPST); field programmable for absolute (non-tracking) or deviation (tracking); can be set anywhere within the scaling of the controller; selectable inhibit and power interrupt; automatic/manual reset
Process Signal Output (Optional):
Linearized, non-isolated 0 to 10 Vdc @ 5 mA; user-selectable scale positioning of zero and full scale; scaling span is 50 to 11,998 counts
RS485 Communications (Optional): Unit with RS485
compatible communications (no CE rating for RS485 option) Dimensions: 48 H x 48 W x 125 mm D (1.88 x 1.88 x 4.925");
115.3 mm (4.54") depth behind panel
Panel Cutout:
45 mm (1.775") square;
1
16 DIN
Weight: 227 g (8 oz) Front-Panel Ratings: NEMA 2,
3R and 12; dust and splash resistant
Page 4
Input Types and Ranges
Input Type Range Resolution Range Resolution
Iron-constantan
Iron-constantan DIN
CHROMEGA®-ALOMEGA
CHROMEGA®-constantan
Copper-constantan
OMEGALLOY
®
-100 to 1600°F 1°F -73 to 87°C 1°C
-100 to 990°F 0.1°F -73 to 871°C 0.1°C
-100 to 1600°F 1°F -73 to 87°C 1°C
-100 to 990°F 0.1°F -73 to 871°C 0.1°C
-200 to 2500°F 1°F -129 to 137°C 1°C
®
-190 to 990°F 0.1°F -129 to 990°C 0.1°C
-100 to 1800°F 1°F -73 to 982°C 1°C
-100 to 990°F 0.1°F -73 to 990°C 0.1°C
-350 to 750°F 1°F -212 to 398°C 1°C
-190 to 750°F 0.1°F -212 to 398°C 0.1°C
-100 to 2372°F 1°F -73 to 1300°C 1°C
nicrosil-nisil -100 to 990°F 0.1°F -73 to 990°C 0.1°C Pt/13%Rh-Pt 0 to 3200°F 1°F -17 to 1760°C 1°C Pt/10%Rh-Pt 0 to 3200°F 1°F -17 to 1760°C 1°C
Pt/6%Rh-Pt/30%Rh 75 to 3308°F 1°F 24 to 1820°C 1°C W/5%Re-W/26%Re 0 to 4208°F 1°F -17 to 2320°C 1°C
100 Pt -328 to 1607°F 1°F -200 to 875°C 1°C
0 0385 curve -190 to 990°F 0.1°F -190 to 875°C 0.1°C
100 Pt -328 to 1607°F 1°F -200 to 875°C 1°C
0 0392 curve -190 to 990°F 0.1°F -190 to 875°C 0.1°C
120 Ni
-112 to 608°F 1°F -80 to 320°C 1°C
-112 to 608°F 0.1°F -80 to 320°C 0.1°C
Process Current 0 to 20 mA, 4 to 20 mA Process Voltage 0 to 5 Vdc, 1 to 5 Vdc
Voltage and current inputs are fully scalable for zero and span. Maximum setting range is -1999 to 9999 counts.
MOST POPULAR MODELS HIGHLIGHTED!
Options
Ordering Add’l Suffix Price Description
-PV $93
-485A** 115 RS485
Note: Only 1 option may be installed in a unit.
No CE rating for -485A option.
**
Scalable recorder; output 0 to 10 Vdc
communications
To Order (Specify Model Number)
Single Output Models Model No. Price Output CN76(*)30 $494 Relay/DC Pulse CN76(*)20 494 DC pulse/AC SSR CN76(*)50 513 0 to 20 mA CN76(*)60 513 0 to 10 Vdc
Comes complete with mounting bracket and operator's manual.
Specify 0 for standard unit, 1 for alarm unit; for alarms, add $35 to price.
*
†† These outputs are logic jumper selectable between relay and DC pulse, or between DC
pulse and AC SSR. Ordering Example: CN76030-485A, CN76000 controller with single relay/DC pulse output
and optional RS485 communications, $494 + 115 = $609.
††
††
Recommended Reference Book:
Controller Tuning PID Without Math,
GE-2117, $23. Visit omega.com/bobi
for Additional Books.
Accessories
Model No. Price Description
1
DPP-4 $475 CNQUENCHARC
16 DIN panel punch
10 Noise suppression kit for mechanical relay models driving AC contactors
or solenoids
Dual Output Models Model No. Price Output 1 Output 2 CN76(*)33 $534 Relay/DC pulse CN76(*)22 534 DC pulse/AC SSR
††
Relay/DC pulse
††
DC pulse/AC SSR
CN76(*)53 554 0 to 20 mA Relay/pulse CN76(*)63 554 0 to 10 Vdc Relay/DC pulse
Specify 0 for standard unit, 1 for alarm unit; for alarms, add $45 to price.
*
†† These outputs are logic jumper selectable between relay and DC pulse, or between DC
pulse and AC SSR. Ordering Example: CN76133-485, CN76000 controller with dual relay/DC pulse outputs,
alarms and optional RS485 communications, $579 + 115 = $694.
††
††
††
††
P-4
P
Page 5
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page