The CN6221 Series is an FM
approved limit controller that can be
configured either as a high limit or
as a low limit controller. The CN6221
features universal input, 2 alarm
outputs, retransmission output, a
timer to count the total time the
setpoint is exceeded, and a register
to retain the maximum. The RS485
communication interface is available
as an option.
Specifications
Power Supply
Voltage: 100 to 240 Vac (±10%),
Frequency: 50 or 60 Hz
Maximum Power Consumption:
8 Va max (4 W max)
Memory: Non-volatile memory
Withstanding Voltage (Between Primary
and Secondary Terminals): 1500 Vac
for 1 min (see Note 1)
Insulation Resistance (Between
Primary and Secondary Terminals):
20 MΩ or more at 500 Vdc (see Note 1)
Note 1: The primary terminals are the power
supply terminals and relay output terminals.
The secondary terminals are the analog input
and output terminals, the voltage pulse
output terminals, and the contact input
terminals.
Contact Input
Function: Resetting “exceeded status”
Input: 1 point
Type: Non-voltage contact
or transistor contact
Contact Capacity: At least 12V/10 mA
On/Off Judgment: On state for 1 kΩ or
less; off state for 20 kΩ or greater
Measured Value (PV)
Input: 1 point
Type: Universal; selectable by software
Accuracy (At 23 ±2°C Ambient
Temperature):
Thermocouple: ±2°C ±1digit
At -200 to -100°C: ±4°C
At -100 to 0°C: ±3°C
Types R and S: ±5°C [±9°C for
0 to 500°C (32 to 932°F)]
Type B: ±9°C (accuracy is not
guaranteed for 0 to 400°C)
RTD: ±1°C ±1digit
Voltage (mV, V): ±0.3% ±1digit
Sampling Period for Measured Value
Input: 500 ms
Burn-Out Detection: Functions for
thermocouple or RTD input (burn-out
upscale only; cannot be switched off)
Input Resistance: 1 MΩ or greater for
thermocouple or DC mV inputs; approx
1 MΩ for DC V input
Maximum Allowable Signal Source
Resistance: 250 Ω for thermocouple or
DC mV input; 2 kΩ for DC V input
Maximum Allowable Wiring
Resistance for RTD Input: 10 Ω/wire
(resistance values of 3 wires must be
the same)
Allowable Input Voltage: ±10 Vdc for
thermocouple or DC mV input; ±20 Vdc
for DC V input
Input Table
Input TypeRange (°C)Range (°F)
-270 to 1370-300 to 2500
-199.9 to 200-300 to 400
-199.9 to 999.9-300 to 2100
-199.9 to 400-300 to 750
-199.9 to 999.9-300 to 1800
-200 to 1300-300 to 2400
-199.9 to 900-300 to 1600
-199.9 to 400-300 to 750
Platinel 20 to 139032 to 2500
-199.9 to 850-199.9 to 999.9
RTDThermocouple
DC
Voltage
Pt100
JPt100-199.9 to 500
0 to 100 mV0 to 100
0 to 5V0 to 5
1 to 5V1 to 5
0 to 10V0 to 10
P-111
-199.9 to 200-300 to 400
-19.9 to 99.9 -199.9 to 999.9
Panel Punches
Available Visit
omega.com/
panelpunches
CN6221-R, $205,
shown smaller
than actual size.
Noise Rejection Ratio:
Normal Mode Noise: Minimum
40 dB (50/60 Hz)
Common Mode Noise: Minimum
120 dB (90 dB for DC V input)
Reference Juction Error
Compensation: ±1.5°C (at 15 to 35°C),
±2.0°C (at 0 to 50°C)
Note: The reference junction compensation
cannot be switched off
0 to 170032 to 3100
0 to 170032 to 3100
0 to 180032 to 3200
0 to 400 32 to 750
Page 2
Control Output
Output: 1 point
Type: Relay contact
Contact Capacity: 3 A @ 240 Vac or
3 A @ 30 Vdc (with resistance load)
Note: The control output relay cannot be
replaced by users.
Alarm Functions (Optional)
Alarm Types: 22 types (waiting action
can be set by software): PV high-limit,
PV low-limit, deviation high-limit,
deviation low-limit, de-energized on
deviation highdlimit, deenergized on
deviation low-limit, deviation high- and
low-limits, high- and low-limits within
deviation, de-energized on PV high-limit,
de-energized on PV low-limit, fault
diagnosis output, fail output
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.