16 DIN Limit Controller
CN6221 Series
Starts at
$
205
Remote Reset
RS485 Communications
(Optional)
Alarms (Optional)Retransmission Output
(Optional)
The CN6221 Series is an FM approved limit controller that can be configured either as a high limit or as a low limit controller. The CN6221 features universal input, 2 alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum. The RS485 communication interface is available as an option.
Specifications
Power Supply
Voltage: 100 to 240 Vac (±10%), Frequency: 50 or 60 Hz Maximum Power Consumption:
8 Va max (4 W max)
Memory: Non-volatile memory Withstanding Voltage (Between Primary
and Secondary Terminals): 1500 Vac
for 1 min (see Note 1)
Insulation Resistance (Between Primary and Secondary Terminals):
20 M or more at 500 Vdc (see Note 1)
Note 1: The primary terminals are the power supply terminals and relay output terminals. The secondary terminals are the analog input and output terminals, the voltage pulse output terminals, and the contact input terminals.
Contact Input
Function: Resetting “exceeded status” Input: 1 point
Type: Non-voltage contact
or transistor contact
Contact Capacity: At least 12V/10 mA On/Off Judgment: On state for 1 k or
less; off state for 20 k or greater
Measured Value (PV)
Input: 1 point
Type: Universal; selectable by software Accuracy (At 23 ±2°C Ambient
Temperature): Thermocouple: ±2°C ±1digit
At -200 to -100°C: ±4°C At -100 to 0°C: ±3°C Types R and S: ±5°C [±9°C for
0 to 500°C (32 to 932°F)] Type B: ±9°C (accuracy is not
guaranteed for 0 to 400°C)
RTD: ±1°C ±1digit Voltage (mV, V): ±0.3% ±1digit
Sampling Period for Measured Value Input: 500 ms
Burn-Out Detection: Functions for
thermocouple or RTD input (burn-out upscale only; cannot be switched off)
Input Resistance: 1 M or greater for thermocouple or DC mV inputs; approx 1 M for DC V input
Maximum Allowable Signal Source Resistance: 250 for thermocouple or
DC mV input; 2 k for DC V input
Maximum Allowable Wiring Resistance for RTD Input: 10 /wire
(resistance values of 3 wires must be the same)
Allowable Input Voltage: ±10 Vdc for thermocouple or DC mV input; ±20 Vdc for DC V input
Input Table
Input Type Range (°C) Range (°F)
-270 to 1370 -300 to 2500
-199.9 to 200 -300 to 400
-199.9 to 999.9 -300 to 2100
-199.9 to 400 -300 to 750
-199.9 to 999.9 -300 to 1800
-200 to 1300 -300 to 2400
-199.9 to 900 -300 to 1600
-199.9 to 400 -300 to 750
Platinel 2 0 to 1390 32 to 2500
-199.9 to 850 -199.9 to 999.9
RTD Thermocouple
DC
Voltage
Pt100
JPt100 -199.9 to 500
0 to 100 mV 0 to 100
0 to 5V 0 to 5 1 to 5V 1 to 5
0 to 10V 0 to 10
P-111
-199.9 to 200 -300 to 400
-19.9 to 99.9 -199.9 to 999.9
Panel Punches
Available Visit
omega.com/
panelpunches
CN6221-R, $205, shown smaller than actual size.
Noise Rejection Ratio:
Normal Mode Noise: Minimum
40 dB (50/60 Hz) Common Mode Noise: Minimum 120 dB (90 dB for DC V input)
Reference Juction Error Compensation: ±1.5°C (at 15 to 35°C),
±2.0°C (at 0 to 50°C)
Note: The reference junction compensation cannot be switched off
Applicable Standards: RTD, Thermocouple, JIS/IEC/DIN (ITS90)
0 to 600 32 to 999.9 0 to 400 32 to 750
0 to 1700 32 to 3100 0 to 1700 32 to 3100 0 to 1800 32 to 3200
0 to 400 32 to 750
Control Output
Output: 1 point
Type: Relay contact
Contact Capacity: 3 A @ 240 Vac or
3 A @ 30 Vdc (with resistance load)
Note: The control output relay cannot be replaced by users.
Alarm Functions (Optional)
Alarm Types: 22 types (waiting action
can be set by software): PV high-limit, PV low-limit, deviation high-limit, deviation low-limit, de-energized on deviation highdlimit, deenergized on deviation low-limit, deviation high- and low-limits, high- and low-limits within deviation, de-energized on PV high-limit, de-energized on PV low-limit, fault diagnosis output, fail output
Alarm Output: 2 relay contacts Relay Contact Capacity: 1 A @ 240 Vac
or 1 A @ 30 Vdc (with resistance load)
Note: The alarm output relays cannot be replaced by users.
Retransmission Output (Optional)
The retransmission output is provided only when the “/RET” option is specified.
Output Signal: Measured value in 4 to 20 mAdc
Maximum Load Resistance: 600 Output Accuracy: ±0.3% of span
(at 23 ±2°C ambient temperature)
Communication Interface
Applicable Standards: Complies with
EIA RS485
Number of Controllers: Up to 31 Maximum Communication Distance:
1200 m (3937') Communication Method: 2-wire
half-duplex, start-stop synchronization, non-procedural
Construction, Mounting, and Wiring Construction:
and drip-proof front panel conforming to IP65; for side-by-side close installation, controller loses its dust-proof and drip­proof protection
Casing: ABS resin and polycarbonate Case Color: Black Mounting: Flush panel mounting
Environmental Conditions
Normal Operating Conditions
Warm-Up Time: At least 30 minutes Ambient Temperature: 0 to 50°C
(0 to 40°C when mounted side-by-side)
Rate of Change of Temperature:
10°C/h or less Ambient Humidity: 20 to 90% RH
(no condensation allowed)
Magnetic Field: 400 A/m or less Continuous Vibrations of 5 to 14 Hz:
Amplitude of 1.2 mm or less
Continuous Vibrations of 14 to 150 Hz:
4.9 m/s
2
(0.5 G) or less
Dust-proof
Short-Period Vibrations: 14.7 m/s (1.5 G) for 15 seconds or less
Shock: 98 m/s Mounting Angle: Upward incline of
up to 30 degrees; no downward incline
Altitude: 2000 m above sea level Maximum Effects from Operating Conditions
Temperature Effects
Thermocouple, mVdc and Vdc Inputs: ±2 µV/°C or ±0.02% of
FS/°C, whichever is the larger
Resistance Temperature Detector: ±0.05°C/°C
Analog Output: ±0.05% of FS/°C
Effect from Fluctuation of Power
Supply Voltage (Within Rated
Voltage Range)
Analog Input: ±0.2 µV/V or ±0.002%
of FS/V, whichever is larger Analog Output: ±0.05% of FS/V
2
(10 G) for 11 ms or less
2
Transportation and Storage Conditions
Temperature: -25 to 70°C (-13 to 158°F) Humidity: 5 to 95% RH
(no condensation allowed) Shock: Package drop height 90 cm (35")
(when packed in the dedicated package)
Dimensions: mm (in)
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No. Price Description CN6221-R $205 Limit controller, single relay output
Options
Ordering Suffix Add’l Price Description
-AL $20 Dual alarms
-PV 40 4 to 20 mA retransmission output
-C4* 95 RS485 communications
-DI * 20 Digital input switching
Only one option can be ordered.
*
Accessories (Field Installable)
Model No. Price Description CNQUENCHARC $8 Noise suppression kit, 110 to 230 Vac DPP-4 475
Comes complete with operator’s manual. Ordering Example: CN6221-R-C4, single output limit controller, mechanical relay, RS485
communications, $205 + 95 = $300.
Recommended Reference Book: Grounding and Shielding Techniques,
EE-1319, $95, See Section Y For Additional Books