Olympus SC50 Installation Manual

Installation Manual
SC50
CMOS color camera
English
Optical Microscope Accessory
Any copyrights relating to this manual shall belong to Olympus Soft Imaging Solutions GmbH. We at Olympus Soft Imaging Solutions GmbH have tried to make the information contained in
Solutions GmbH disclaims any warranty of any kind, whether expressed or implied, as to any
matter whatsoever relating to this manual, including without limitation the merchantability or
fitness for any particular purpose. Olympus Soft Imaging Solutions GmbH will from time to time
revise the software described in this manual and reserves the right to make such changes
without obligation to notify the purchaser. In no event shall Olympus Soft Imaging Solutions
GmbH be liable for any indirect, special, incidental, or consequential damages arising out of
purchase or use of this manual or the information contained herein.
No part of this document may be reproduced or transmitted in any form or by any means,
electronic or mechanical, for any purpose, without the prior written permission of
Olympus Soft Imaging Solutions GmbH.
All brands are Trademark or registered Trademark of their respective owners.
© Olympus Soft Imaging Solutions GmbH
All rights reserved
Printed in Germany
510_UMA_InstallationSC50_en_00_30September2014
Olympus Soft Imaging Solutions GmbH, Johann-Krane-Weg 39, D-48149 Münster,
Tel. (+49)251/79800-0, Fax.: (+49)251/79800-6060
Contents
1The SC50 CMOS color camera . . . . . . . . . . . . . . . . . . 4
1.1 Scope of supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.3 Operating and storage conditions . . . . . . . . . . . . . . . . . . . . . .6
2General safety instructions . . . . . . . . . . . . . . . . . . . . 7
2.1 Avoiding personal injuries . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.2 Avoiding device damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
3System environment . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1 Microscope and camera adapter . . . . . . . . . . . . . . . . . . . . . .10
3.2 Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.3 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1 Step 1: Insert USB 3.0 PCI express card . . . . . . . . . . . . . . . .13
4.2 Step 2: Install USB 3.0 PCI express card driver . . . . . . . . . . .14
4.3 Step 3: Install the software . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4.4 Step 4: Connect the camera . . . . . . . . . . . . . . . . . . . . . . . . .18
5Care and maintenance . . . . . . . . . . . . . . . . . . . . . . . 20
6Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.1 The installation program won't start . . . . . . . . . . . . . . . . . . . .21
6.2 The camera can't be found . . . . . . . . . . . . . . . . . . . . . . . . . . .21
6.3 A faulty image appears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
6.4 The camera isn't available in the software . . . . . . . . . . . . . . .26
6.5 You receive an error message when you start the live-image 26
6.6 A different problem has occurred . . . . . . . . . . . . . . . . . . . . . .27
7Notes on conformity and disposal . . . . . . . . . . . . . . 29
8Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CMOS color camera SC50
4
1The SC50 CMOS color camera
1.1 Scope of supply
The camera's scope of supply comprises:
Camera with protective capUSB 3.0 cableInstallation manualUSB 3.0 PCI express card with driver on CD and power supply cableAdapter cable for the USB 3.0 PCI express card's power supply (SATA to IDE)
CMOS sensor
USB port type B
Camera
USB plug type A
USB plug type B
USB 3.0 PCI express card
USB cable Installation manual
1 The SC50 CMOS color camera
5
Other essential
components
To be able to use the camera, you'll also need the following components:
Computer with MS-Windows operating systemLight microscope with camera adapter or something similar, for example a
macro stand
Software to operate the camera (see chapter 3.3 on page 12)
1.2 Specifications
Properties of
the SC50
The SC50 is a CMOS color camera with a high frame rate. It was designed for biomedical and material sciences applications, but not for clinical diagnostic purposes. It was specially developed for acquisitions using light microscopy.
The SC50 is of a compact design and can be connected to all common types of light microscope by a C-mount. The ICC profile technology guarantees an optimal color mapping.
Binning modes
The SC50 has two binning modes. In binning mode, the camera's CMOS sensor combines neighboring pixels into pixel blocks. This results in a higher sensitivity and a shorter processing time, but also in a lower resolution.
Technical data SC50
Chip type CMOS
Chip size 1/2.5 Inch
Effective area (width x height) 5.6 mm x 4.2 mm
Pixel size 2.2 µm x 2.2 µm
Maximum resolution 2560 x 1920 pixels
Bit depth 24 bit, 48 bit
Read-out speed 5 – 104 MHz
Interface USB 3.0
Camera mount Standard C-Mount
Binning Image format Resolution Max. frame rate Exposure times
Maximum resolution 4:3 2560 x 1920 pixels 15 frames per second 0.03 ms - 2.74 s
Binning 2x2 4:3 1280 x 960 pixels 36 frames per second 0.02 ms - 1.7 s
Binning 4x4 4:3 640 x 480 pixels 47 frames per second 0.02 ms - 1.8 s
Maximum resolution 16:9 (Full HD)1920 x 1080 pixels32 frames per second 0.03 ms - 1.8 s
Binning 2x2 16:9 960 x 540 pixels 71 frames per second 0.018 ms - 1.3 s
Binning 4x4 16:9 480 x 270 pixels 77 frames per second 0.018 ms - 1.57 s
CMOS color camera SC50
6
1.3 Operating and storage conditions
Please operate and store your camera in the following conditions:
The maximum permissible range for the ambient temperature during camera
operation is +0°C to + 45°C.
The maximum permissible relative humidity during camera operation is 80 %
(condensation free).
When the camera is stored or transported, the ambient temperature must be
kept between -20°C and + 60 °C.
Indoor use only.Maximum altitude: 2000 m.
2 General safety instructions
7
2General safety instructions
The camera has been developed and produced in conformity with recognized safety regulations. However, it is not possible to entirely rule out possible hazards for the user, damage to the camera or microscope, or impairments of the camera's func­tionality. For this reason, always read and follow the general safety instructions and warnings before and during the installation.
Serious injuries can occur
The warning sign and the word Warning indicate dangerous situations that can lead to serious injuries or even death if ignored.
Light injuries can occur
The warning sign and the word Caution indicate dangerous situations that can lead to light injuries if ignored.
Damage to devices can occur
The exclamation mark and the word Attention indicate situations, where irreparable damage to the camera, microscope or computer can occur if ignored.
Reduced functionality can occur
Notices only printed with an exclamation mark indicate that ignoring them can reduce or hamper the camera's functionality.
Warning
Caution
Attention
CMOS color camera SC50
8
2.1 Avoiding personal injuries
2.2 Avoiding device damage
Electric shock due to damaged cable!
When a cable is frayed or damaged, a person touching it risks the danger of an electric shock.
Shut off the hardware and replace the cable immediately!
Poisoning due to toxic gases!
In the case of a fire, the material of the camera can give off toxic gases. When these are inhaled, it can cause irritation of the respiratory passages and damage to them.
Wear respiratory protection when fighting the fire!
Tripping hazard!
Cables laid across a room can be a dangerous tripping hazard. This can cause injuries to people and damage to equipment.
Wherever possible, lay cables along the wall or behind furniture. Fix cables that run across the room into place!
Never open the camera housing!
The camera's CMOS chip is extremely sensitive. Electrostatic discharge can permanently damage the camera.
Therefore, never, under any circumstances, open the camera housing!
Avoid vibration shocks!
Mechanical shocks and strong vibrations can damage the camera.
Don't drop the camera during installation. Make sure it is securely mounted on the microscope. When it's not in use, store it in a safe place!
Secure microscopes with additional components!
A top-heavy microscope can tip over or fall down and result in damage to both the camera and the microscope.
If the microscope is top-heavy or otherwise unstable, fix it!
Warning
Warning
Caution
Attention
Attention
Attention
2 General safety instructions
9
Don't touch the protective glass!
The protective glass over the CMOS chip is extremely sensitive and must not come into contact with bare hands or any other objects, otherwise the acquisitions will be impaired by fingerprints or scratches.
Remove dust from the protective glass carefully with compressed air. Ionized air is recommended for removing dust which is adhered by static electricity.
Observe the operating conditions!
Exposure to high temperatures or humidity can damage component parts of the camera.
Always observe the operating and storage conditions (see chapter 1.3 on page 6)!
Don't expose the camera to strong light!
Exposure to strong light can cause the camera to overheat, which may cause damage to its component parts.
Do not expose the camera to strong light (such as sunlight) for long periods of time.
Only use the USB cable that is delivered with your camera
Operate the camera only with the USB cable that is part of the camera's scope of supply. This ensures that the EMC basic standards are fulfilled.
Attention
Attention
Attention
Attention
CMOS color camera SC50
10
3System environment
3.1 Microscope and camera adapter
Suitable camera
adapters
The system table shows the camera adapters you can use to connect the SC50 to common Olympus microscopes. Please note that you can also use microscopes that are not listed there. Basically, all of the camera adapters with the magnification factor 0.5 or larger are suitable.
U-CMAD3
U-TV1x-2
U-TV0.5xC-3 U-TV0.63xC
GX-TV0.5xC GX-TV0.7xC
SC50
MVX-TV0.63xC
MVX-TV1xC
Upright microscope
BX61/ BX51/ BX41 CX41/ CX31/ MX61 MX61L/ MX51 BX43/ BX46/ BX53 BX63
Inverted microscopes
IX81/ IX71/ IX51 IX83/ IX73/ IX53
Stereo microscopes
SZX16/ SZX10 SZX7/ SZ61
Inverted metallography microscopes
GX71/ GX51
Fluorescence microscope
MVX10
USB cable
Camera
Software with camera driver
Camera adapter
3 System environment
11
3.2 Computer
3.2.1 System requirements for the computer
For optimal use, the system requirements listed in the table must be fulfilled.
*Make sure that the software you want to operate the camera with supports one of the operating systems listed here.
System requirements
Required Recommended
Processor (CPU) Intel i3, i5, i7 or the corresponding
XEON processors compatible AMD processors
4 or more physical cores
2.5 GHz
Hard disk at least 30 GB free storage space
RAM 4GB 8GB
Screen resolution at least 1280 pixels x 1024 pixels
VGA board 32-bit graphics card
at least 128 MB graphics memory
Drive DVD-ROM drive
Interfaces a free USB 3.0 PCI slot
(Generation 2, 1x)
Operating systems* MS-Windows 8 / 8.1 (32 bit or 64 bit)
MS-Windows 7 (32 bit or 64 bit)
Computer power supply
> 300 W and a free power supply socket
Latest system requirements available from customer service
The system requirements listed here are current at the time of creating this manual. The system requirements are often updated by the manufacturer. The latest requirements can be obtained by asking customer service at Olympus Soft Imaging Solutions. To do so, send an e-mail to the following address: