SIMENS STAR CHART ................................................................................................... C-9
CHECKING OF LENS UNIT ........................................................................................... C-10
C-1Ver.1/Rev.2
C. ADJUSTMENT METHODC-3100ZOOM/C-3020ZOOM
[1] Table for Servicing Tools
Ref. No.
J-1
J-2
J-3
J-4
J-5Extension cord
J-6
Note: J-1 color viewer is 100 - 110 VAC only.
Color viewer
Siemens star chart
Calibration software
Extension cord
Chart for color adjustment
Name
Number
1
1
1
1
1
1
J-1J-2
J-3
J-4/J-5
Part code
VJ8-0007
VJ8-0184
VJ8-0162
VJ8-0165
VJ8-0155
[2] Equipment
1. Oscilloscope
2. Digital voltmeter
3. AC adaptor
4. PC (IBM R -compatible PC, Pentium processor, Window
98 or Me)
[3] Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. 5.1 V (A) Voltage Adjustment
3. 5.0 V (L) Voltage Adjustment
4. Lens Adjustment
5. AWB Adjustment
6. Color matrix Adjustment
7. CCD White Point Defect Detect Adjustment
8. CCD Black Point Defect Detect Adjustment
9. LCD Panel Adjustment
9-1. LCD H AFC Adjustment
9-2. LCD RGB Offset Adjustment
9-3. LCD Gain Adjustment
9-4. LCD Blue Brightness Adjustment
9-5. LCD Red Brightness Adjustment
9-6. LCD VcomPP Adjustment
Note:
1. If the lens, CCD, board and changing the part in item 4-
8 replace, it is necessary to adjust again. Item 5-7 adjustments should be carried out in sequence. Item 8 adjustments should be carried out after item 5.
J-6
[4] Setup
1. System requirements
Windows 98 or Me
IBM R -compatible PC with pentium processor
CD-ROM drive
3.5-inch high-density diskette drive
USB port
40 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into
your diskette drive.
2. Open Explorer.
3. Copy the DSC Cal folder on the floppy disk in the FD
drive to a folder on the hard disk.
3. Installing USB drive
Install the USB drive with camera or connection kit for PC.
C-2Ver. 1
C. ADJUSTMENT METHODC-3100ZOOM/C-3020ZOOM
[5] Connecting the camera to the computer
1. Line up the arrow on the cable connector with the notch on the camera's USB port. Insert the connector.
2. Locate a USB port on your computer.
USB cable
To USB port
AC adaptor
Ver. 1
C-3
C. ADJUSTMENT METHODC-3100ZOOM/C-3020ZOOM
[6] USB Storage Information Registration
USB storage data is important for when the camera is connected to a computer via a USB connection.
If there are any errors in the USB storage data, or if it has
not been saved, the USB specification conditions will not be
satisfied, so always check and save the USB storage data.
Preparation:
POWER switch: ON
Adjustment method:
1. Connect the camera to a computer. (Refer to [5] Connecting the camera to the computer on the page C-3.)
2. Double-click on the DscCalDi128.
3. Click on the Get button in the USB storage window and
check the USB storage data.
VID: OLYMPUS
PID: C-3100Z/C-3020Z
Serial:
Rev. : 1.00
4. Check the “Serial” in the above USB storage data. If the
displayed value is different from the serial number printed
on the base of the camera, enter the number on the base
of the camera. Then click the Set button.
5. Next, check VID, PID and Rev. entries in the USB storage data. If any of them are different from the values in
3. above, make the changes and then click the corresponding Set button.
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB strage
VID
Get
PID
Set
OK
OK
Upload
Firmware
Image
Initialize
EVF
LCD Type
LCD
R Bright
RGB Offset
Tint
VCO
H AFCTest
Serial
Set
Set
Rev.
B Bright
Gain
Phase
Set
Set
VCOMDC
VCOMPP
Setting
Language
Video Mode
[7] Adjust Specifications
[ST1 board (Side B)]
CL524
(Side A)
VR504
VR502
VR501
CL522
CL501
(Side A)
Q5001
Collector
(Side A)
Note:
1. Voltage adjustment is necessary to repair in the ST1 board
and replace the parts.
2. Carry out adjustment with disconnect wires for storbe.
Preparation:
1. Connect the SY1 board (CN301) and the CA2 board
(CN106) with extension cord. (VJ8-0165)
2. Connect the ST1 board (CN501) and the CA2 board
(CN104) with extension cord. (VJ8-0162)
3. Connect LCD panel.
4. Insert the card.
5. Turn on the power switch, and then set the camera mode.
1. IC501 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Q5001 Collector or CL501
Frequency counter
VR501
200 ± 1 kHz
Adjustment method:
1. Adjust with VR501 to 200 ± 1 kHz.
2. 5.1 V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR502 to 5.10 ± 0.05 V.
C-4Ver. 1
CL524
Digital voltmeter
VR502
5.10 ± 0.05 V