C-3100ZOOM / C-3020ZOOM
E. NOTICE OF MODIFICATION
1. Firmware version up for the countermeasure of the date order problem.........E-2
2.
3. Correction of parts number.........................................................................E-4
Firmware version up for the countermeasure of “SDK”................................E-3
E-1 Ver.1/Rev.4
E. NOTICE OF MODIFICATION C-3100ZOOM / C-3020ZOOM
SUBJECT
Firmware version up for the countermeasure of
the date order problem.
DESCRIPTION: Change of Firmware for C-3100 Zoom / C-3020 Zoom.
Destination OLD VERSION NEW VERSION
ALL v374-73 v374-74
Reason:
Even if a power supply is turned off, it is fixed on the order which date order was set up to.
* Date order must be set at your countries one when it exchange Compl PWB CP-1.
Serial number information
Destination Old version (v374-73)
the object machine type
217100153 ~ 217105000
USA
EUROPE 218300001 ~ 218307112
JAPAN None
OTHERS
217110001 ~ 217111970
217300001 ~ 217304992
217310001 ~ 217312112
220100001 ~ 220100576 220100577 ~ 220103776
New version (v374-74)
the object machine type
217105001 ~ 217110000
217111971 ~ 217114000
217304993 ~ 217310000
217312113 ~ 217314000
218100001 ~ 218105000
218307113 ~ 218317000
219100001 ~ 219105000
219300001 ~ 219314000
2002.03.29
REMARKS:
Change classification: Running change.
Version up procedure:
1. Rename the binary data of the latest firmware with “firmware.bin”.
Create a folder “Firmware” in the smart media which was formatted on C-3100 Zoom, and save the binary data
“firmware.bin” into the folder “Firmware”.
2. Insert the F/W card for C-3100 Zoom and turn the camera on at play mode.
3. TFT-LCD shows F/W version and inquiry of F/W rewriting.
Then select “YES” (Character is changed green) and after pressing “OK”, rewriting of F/W is started
automatically.
4. During the rewriting of F/W, SELF-RED is turned on and showed “EXCHANING” on TFT-LCD.
It will take about 2 minutes but please do not operate any key, and do not turn off power.
It might have damaged camera body and F/W.
5. After the rewriting of F/W, TFT-LCD was showed as same as procedure 3.
Then confirm new version “No.” of F/W (v374-74) and turn off power after selecting “NO”.
(The discrimination of countermeasure is not showed due to confirm easily.)
E-2 Ver.1