Quick Start Guide Scout
Calibration Mass (only for models up to 620g
capacity)
Release the red Transportation
Lock on subplatform of the
balance
Turn the pointer 90 counterclockwise.
Install the Pan
Rectangular pan: Place diagonally
on sub-platform and rotate
counter-clockwise until it locks.
Round pan: Set straight down on
subplatform.
Connect Power
Connect the AC Adapter to the
balance input jack.
Battery Installation
Install the Four “AA” (LR6)
batteries (not included) with
polarity as shown in the battery
compartment.
Level the balance
Level the balance before using by
adjusting the feet until level
bubble is center
Transportation
Lock Pointer
SPX Balances
UNPACKING
Carefully remove your Scout balance and each of its components from the
package. Store the packaging material to ensure safe storage and future transport.
Included Components:
SELECTING THE LOCATION
Place on a firm, steady surface with sufficient space. Avoid excessive air current,
vibrations, heat sources, or rapid temperature changes.
Ohaus Corporation www.ohaus.com i Scout
SPX Balances
Scout SPX Balances Quick Start Guide
CAUTION: Read all safety warnings before installing, making
connections, or servicing this equipment. Failure to comply with these
warnings could result in personal injury and/or property damage. Retain
all instructions for future reference.
SAFETY PRECAUTIONS
Verify that the local AC power supply voltage is within the input voltage range
printed on the AC adapter’s ratings label.
Only connect the AC adapter to a compatible grounded socket.
Position the instrument such that the AC adapter can be easily disconnected
from the socket.
Position the power cord so that it does not pose a potential obstacle or tripping
hazard.
Operate the equipment only under ambient conditions specified in the user
instructions.
Do not operate the equipment in hazardous or explosive environments.
Disconnect the equipment from mains power before cleaning or servicing.
Service should only be performed by authorized personnel.
CONTROLS
Button Functions
Scout
SPX Balances ii Ohaus Corporation www.ohaus.com
Quick Start Guide Scout
Zero/On
Turns the
balance on;
If balance is
On, sets Zero
Function
Initiates an
application
mode
Off
Turns the
balance Off
Units
Changes the
weighing unit
Mode
Changes the
application
mode
Menu
Enters the
User menu
Short Press
(Menu
Function)
Yes
Accepts the
current setting
No
Advances to
the next menu
or setting
Back
Moves to
previous
menu item
Press and hold Menu until [mMeNU] (Menu) is displayed.
Release the button, the display will show [C.A.L].
Press Yes to accept. [SpaN] will then be shown.
Press Yes to begin the span calibration. Zero reading is stored
automatically.
Place the specified span calibration mass or press No to select an
alternate weight.
[--C--] will be displayed while the reading is stored
The display will show [done] if the calibration was successful. The balance
returns to the previous application mode and is ready for use.
SPX Balances
CALIBRATION
When the balance is operated for the first time, a span calibration is
recommended to ensure accurate weighing results. With balance turned on:
OPERATION & APPLICATIONS
The balance can be configured to operate in various Application modes. Press
and hold Mode key to select your Application mode.
The Scout SPX balance incorporates the following Applications:
Ohaus Corporation www.ohaus.com iii Scout
SPX Balances
Scout SPX Balances Quick Start Guide
Reset
Yes/No
Filter
Low/Med/High
AZT
0.5/1/3/Off
StableRange
0.5/1/2//5
Backlight
Off/On/Auto
Auto Tare
Off/On/On-acc
Auto Off
Off/1/5/10
Reset
Yes/No
Weighing
On/Off
Counting
On/Off
Percent
On/Off
Check
On/Off
Totalize
On/Off
Hold
Disp/Peak/Off
Reset
g
kg
ct
N
oz
ozt
dwt
lb
lb:oz
grn
hkt*
sgt*
twt*
t*
tola/tical
C
Note: Bold fonts are default settings in the menus. * Only available in certain regions.
Use an optional interface connectivity kit to
connect the balance either to a computer,
printer or OHAUS auxiliary display.
Below Interface kit accessories are available:
RS232, USB Host, USB Device, Ethernet,
Bluetooth*.
Interface connection on the rear of
the balance:
* Interface kits may vary according to local regulations
Short press –
Go to
Next/Prev.
menu
Weighing
1. Press the Zero/On button to turn the balance on.
2. Select Weighing (this application is the default) by pressing & holding Mode
key.
3. Press Tare or Zero if necessary to begin.
4. Place objects on the pan to display the weight. When stable, the * appears.
The display shows the resulting value of the sample.
MENU STRUCTURE
ADDITIONAL FEATURES
Connecting the Interface
Scout
SPX Balances iv Ohaus Corporation www.ohaus.com
Quick Start Guide Scout
This product complies with the EU Directives 2014/30/EU (EMC),
2014/35/EU (LVD) and 2014/31/EU (NAWI). The EU Declaration of
Conformity is available online at www.ohaus.com/ce.
This product complies with the EU Directive 2002/96/EC (WEEE).
Please dispose of this product in accordance with local regulations at
the collecting point specified for electrical and electronic equipment.
For disposal instructions in Europe, refer to www.ohaus.com/weee.
AS/NZS 61000.6.1, AS/NZS 61000.6.3
CAN/CSA-C22.2 No. 61010-1
UL Std. No. 61010-1
For more detailed information about the balance,
please refer to the product instruction manual. The
instruction manual can be obtained either by
scanning the QR code or by going to the product
page and from there download it. Go to
www.ohaus.com to register your product's warranty.
Product Page: http://www.ohaus.com/
Weigh below protective cover
Weigh Below Hook
The weigh below hook is located at the reverse side of the battery cover as shown.
To use this feature, remove the red protective cover underneath for the weigh below
opening.
SPX Balances
COMPLIANCE
Compliance to the following standards is indicated by the corresponding mark on
the product.
INSTRUCTION MANUAL
Ohaus Corporation www.ohaus.com v Scout
SPX Balances