Front pushbutton must have diode (supplied) assembled across the
screw terminals as shown in Figure 3.
NOTE: Upon completion of installation, if the chime does
not operate properly, check the pushbutton(s) for poor contact
or loose connections. Be certain wires are not touching the
tone bars.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Lighted Door Chimes
LA-156PR, LA-163, LA-164
or LA-165 Series
WIRING
BE SURE HOUSE POWER IS TURNED OFF WHEN WIRING THE
TRANSFORMER. WIRING CONNECTIONS MUST COMPLY WITH
LOCAL OR NATIONAL WIRING CODES.
• For chime installation, use NuTone Model 101T Transformer.
NOTE: When fastening chime wiring to wall studs and ceiling joists,
care must be taken to avoid possible “shorts” that might be created by
allowing staples or clips to cut through the protective wiring insulation.
Refer to Figure 1. Mount the
transformer to a convenient junction box
(attic location is not recommended) or
circuit breaker box. Connect house
power leads to transformer leads –
black to black and white to white.
Refer to Figure 2. Run 2 conductor
18 gauge wire from transformer and the
pushbutton(s) to chime location.
Remove fiberboard shield from front of chime base by gently pulling
forward until it disengages from the chime. Bring the wires through the
wiring hole in the chime baseplate and fasten the baseplate to the wall
through the mounting holes with the screws provided. Connect the
transformer and the pushbutton wires to the chime terminal board as
shown in Figure 2. Replace fiberboard shield.
FIGURE 1
FIGURE 3
CLIP DIODE LEADS TO
3/8" AND INSERT INTO
TERMINALS
RECESS
MOUNTED
PUSHBUTTON
WRAP DIODE LEAD AROUND EACH
TERMINAL SCREW AND CLIP EXCESS
WRAP
DIODE LEAD
AROUND
EACH
TERMINAL
SCREW
RECESS
MOUNTED
PUSHBUTTON
INSTALLING THE PUSHBUTTONS
A diode must be added to the front door pushbutton so that
power will be supplied continuously to the Chime.
The diode is packed inside an envelope that is located in the chime
package.
A diode is not required at the back door pushbutton.
PLANNING
• Your NuTone Door Chime is designed for two-door operation.
• Handle the door chime carefully, as you would any precision instrument.
To add the diode to the front door's pushbutton:
1. Remove the pushbutton from the door jamb or wall.
2. Refer to Figure 3. Depending upon which type of pushbutton is
being used, wire the diode to the two (2) terminals on the
pushbutton.
3. Be sure the wire on the end with the silver band goes to the screw
terminal wired to the transformer
.
4. Press the front door pushbutton and listen for the chime to sound.
5. If the chime does not sound when the button is depressed, the
diode is installed backwards. Simply reverse the wiring
connections on the pushbutton and test the chime again.
6. Tighten the terminal screws and replace the pushbutton in the door
jamb or wall. Note: on metal siding, place a small piece of
insulating tape on the surface opposite the diode to prevent
shorting.
NOTE: If you are using a lighted pushbutton, the bulb's
brightness will be reduced 30-40%. This is normal and will
increase life of the bulb.
DIODE
TRANS
FRONT
SILVER BAND
The following test can be used to test for correct installation of
diode at pushbutton if power is not available. NOTE: If diode is
installed backwards and power is applied to the chime, damage to
the diode, chime or transformer will occur.
1. Power to chime transformer must be off.
2. Wire the chime per the instructions supplied. Connect the diode
across the chime pushbutton (remove bulb if pushbutton is lighted).
3. Remove the wire from the front screw terminal at the chime.
4. Connect an ohmmeter selected to the diode position (or lowest ohms
scale if no diode position exists) to the front wire and transfomer
screw terminal on chime.
5. Measure with the (+) lead connected to the front wire and the (-) lead
connected to the transformer screw terminal - Record measurement
of ohmmeter.
6. Reverse the ohmmeter wires so the (-) lead is connected to the front
wire and the (+) lead connects to the transformer screw terminal Record measurement of ohmmeter.
7. For the chime to operate correctly the ohmmeter reading must be
less (lower reading) when the (-) lead is connected to the transformer
and the (+) lead is connected to the front wire.
8. If #7 is incorrect, reverse the diode at the pushbutton and redo steps
4, 5, and 6 to verify the correct reading in step 7.
9. After verifying the correct placement of the diode, reconnect the front
wire to the front screw terminal on the chime and replace bulb in
pushbutton if removed for test.
DIODE TEST
FIGURE 2
FRONT DOOR
PUSHBUTTON
SINGLE 2-NOTE CHIME
18 GA. INSULATED
2-CONDUCTOR WIRE
NUTONE 101T
TRANSFORMER
120vAC WIRING
REAR DOOR
PUSHBUTTON
TERMINAL
BOARD
FRONT
TRANS
REAR
DIODE
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, OH 45227
Printed in U.S.A., Rev. 5/01, Part No. 86527
MOUNTING COVER
Install the chime cover over the baseplate.
MAINTENANCE INSTRUCTIONS
If chime plungers should ever become “sluggish” in their
movement, clean plungers with a nonflammable cleaning fluid and
wipe dry.
CAUTION: NEVER OIL CHIME PLUNGERS.
REPLACEMENT PARTS OR SERVICE
Contact your local Authorized NuTone Parts Outlet or Service
Center. If you are unable to locate the facility, write NuTone Inc.,
4820 Red Bank Road, Cincinnati, Ohio 45227-1599.
Attention: Department of National Field Service.
One Year Limited Warranty
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
Rev. 03/2001