TIE-06006
2006/01/23
H.Masumoto
Mgr
Chf
T.Ogasahara
H. Tsuru
D200》Revision of STD.DAT in Image adjustment software (J65084)
《
Summary
Regarding D200 image adjustment software (J65084), sometimes errors occurred in
"BLACK POINT" of
"PIXEL DEFECT COMPENSATION". Therefore, "STD.DAT" le, which is included in the software, has been
changed and the software that rewrites "STD.DAT" le has been created as follows:
Contents
Revision: ・ The judgment level of luminance was changed in "BLACK POINT" of "PIXEL DEFECT
COMPENSATION".
Method: The already revised "STD.DAT" will be distributed for the new distribution of the software.
The date of the revised le is "2006-01-20", so check for the revision by this date.
At departments where the reference value was already obtained/used, or if the date of
"STD.DAT" is earlier than the above, use the dedicated software "D200STDW.EXE" and
rewrite "STD.DAT" based on the below procedure.
If the reference value was already obtained/used, getting the reference value again by the
following procedure is NOT necessary.
1. Copy the dedicated software for rewriting "STD.DAT" le (D200STDW.EXE), into the
folder where D200 image adjustment software exists.
2. Double-click "D200STDW.EXE" to start up.
3. Click "OK" and perform rewriting.
4. Conrm that <OK> is indicated in the end.
Internal and subcontractors' use only
Caution:
If the "STD.DAT" le is broken or of another model, <ERROR> is indicated and nished.
Check for the folder and perform the above 1.-4.again if the folder is not correct. However,
if <ERROR> still appears, copy the image adjustment software again, and reobtain the reference value.
P1/1