Nice Automation RUN 2500I User Manual

Run 2500 Inverter
(GB) CAUTION:
The product has undergone an update: in the version Run 2500 I, replace the corresponding parts of the man ual enclosed with the product, with the following updated sections:
RUN 2500 I is powered by a common single phase 230V electric power line. It is equipped with a po werf ul and efficient 3-phase motor controlled by a special “inverter” control unit, which enables adjustment of speed.
7.2.1) Level one functions (ON-OFF functions)
Table 7: programmable function list: level one
LED Function Description
On activation of this function, a deceleration phase is activated at the end of the opening or closing manoeuvre. The final deceleration speed corresponds to approx. 0.05 m/s, regardless of the speed set
L4 Deceleration
7.2.3) Level two functions (adjustable parameters)
Table 9: programmable function list: level two
Input LED Parameter LED (level) Value Description
during the manoeuvre. If deceleration is not active the speed remains constant throughout the manoeuvre. Caution: Run 2500 I maintains the same force applied during the manoeuvre also during deceleration; therefore deceleration can also be implemented on very heavyweight gates.
ISTRUI-FA-GBR01.4865
Adjusts motor speed during normal travel.
Adjusts the sensitivity of obstacle detection.
L3
L5
Motor speed
Obstacle detection sensitivity
L1 L2 L3 L4 L5 L6 L7 L8
L1 L2 L3 L4 L5 L6 L7 L8
Speed 0,06m/s Speed 0,09m/s Speed 0,13m/s Speed 0,17m/s Speed 0,20m/s Speed 0,25m/s Speed 0,17m/s in opening; 0,09m/s in closing Speed 0,25m/s in opening; 0,17m/s in closing
Extremely high sensitivity (lightweight gates) Very high sensitivity High sensitivity Medium sensitivity Medium-low sensitivity Low sensitivity Very low sensitivity (heavyweight gates) Detention excluding (for gates with jolts)
8) Technical characteristics
Run 2500 I Technical characteristics
Product Type
Maximum torque on start-up (corresponds to the force required to move the leaf)
Nominal torque (corresponds to the force required to maintain the leaf in movement)
No-load speed Speed at nominal torque Maximum frequency of operating cycles
(at nominal torque) Maximum time of continuous operation
(at nominal torque) Run 2500 I Power supply
Maximum power absorption on start-up [corresponding to Amps] Power at nominal torque [corresponding to Amps]
Note ** at 50°C and with a gate of 17.5 m the maximum operating frequency is 6 cycles/hour (equal to a cycle of 35%). Note *** at 50°C the maximum continuous operating time is 20 minutes.
Electromechanical gearmotor with three-phase motor for automatic movement of sliding gates for industrial use complete with electronic control unit and inverter.
60Nm (1660N)
25Nm (700N)
0.17m/s with speed = L4; the speed is adjustable from 0.06 to 0.25m/s 0,15m/s with speed = L4 28 cycles/hour (672 cycles/day), for a gate of 10m; equal to a cycle of 93%. The control
unit limits the cycles to the maximum limits as specified in tables 2 and 3) 45 minutes. The control unit limits continuous operation to the maximum limits as specified in tables 2 and 3)***
230Vac (+10% -15%) 50/60Hz 650W [3.7 A]
450W [2.6 A]
**
Loading...