NEC EA2 User Manual

查询EA2-12供应商查询EA2-12供应商
DATA SHEET
MINIATURE SIGNAL RELAY
EA2 SERIES
COMPACT AND LIGHTWEIGHT
DESCRIPTION
The EA2 series has reduced package size and power consumption to other NEC Conventional relays. Furthermore, it complies with 1500 V surge-voltage requirement of FCC part 68 by the unique structure and the efficient magnetic circuit
FEATURES
Low power consumptionCompact and light weight2 form c contact arrangementLow magnetic arrangementBreakdown voltage : 1000 Vac (surge voltage 1500 V), FCC Part 68 compliantTube packagingUL recognized (E73266), CAS certified (LR46266)
APPLICATIONS
Electronic switching systems, PBX, key telephone systems, automatic test equipment and other electronic equip­ment.
ATTENTION
DO NOT EXCEED MAXIMUM RATINGS.
Do not use relays under exceeding conditions such as over ambient temperature, over voltage and over current. Incorrect use could result in abnormal heating, damage to related parts or cause burning.
READ CAUTIONS IN THE SELECTION GUIDE.
Read the cautions described in NEC's "Miniature Relays" (ER0046EJ) when you choose relays for your application.
Document No. ER0001EJ6V0DS00 (6th edition) Date Published June 1999 M Printed in Japan
©
1989 (1996)
EA2 SERIES
OUTLINE DRAWING AND DIMENSIONS PAD LAYOUT (bottom view)
Unit : mm (inch)
14.2 max. (0.56)
0.33 (0.013)
0.5
(0.02)
2.54
(0.10)
+
Note. tolerance 0.2 ( 0.008) unless otherwise specified
Dimensions in show basic size.
+
NJ type : Cover height-6.3 mm (0.248), Leads-2.8 mm (0.11)
(0.21)
5.4 max.
3.5
9.2 max. (0.36)
0.25
(0.01)
7.62
(0.30)
MARKINGS
1
2
5
EA2-5
JAPAN
Standard type
9106
w Manufacturer e Country of origin
q Part number
43
r Date code t Index mark of relay direction
(pin No. 1, 10.)
1
y UL, CSA Marking
φ
10- 0.8(0.03)
7.62
(0.30)
2.54
(0.10)
10.16
2.54
(0.10)
(0.40)
+
Note. Tolerance 0.1 ( 0.004) unless othewise specified
+
SAFETY STANDARD AND RATING
UL Recognized
(UL508)
File No E73266
30 Vdc, 1 A (Resistive) 110 Vdc, 0.3 A (Resistive) 125 Vdc, 0.5 A (Resistive)
Spacing : UL114, UL478
CSA Certificated
(CSA C22.2 No 14)
File No LR46266
EA2-5NU
JAPAN
5
9106
UL recognized, CSA certified type
PIN CONFIGURATIONS
12345
+
Index mark of relay direction
10 9 8 7 6
(not energized position)
2
3
46
Non-latch type
12345
+
R S
+
10 9 8
Single coil latch type
(reset position)
76
S
123
+
+
45
10 9 8 7 6
R
Double coil latch type
(reset position)
S : Coil polarity of set (operate) R : Coil polarity of reset (release)
2
DATA SHEET ER0001EJ6V0DS00
EA2 SERIES
PART NUMBER SYSTEM
EA2 – 3 S NU
Nil : Standard type NU : UL recognized, CSA certified type NJ : Trimmed leads type NP : Silver-palladium alloy contact (with gold alloy overlay) ∗
UL recognized, CAS certified type
Latch type
Nil : Non-latch type (standard type) S : Single coil latch type T : Double coil latch type
Nominal coil voltage
3, 4.5, 5, 6, 9, 12, 24 Volts
EA2 series
PERFORMANCE CHARACTERISTICS
Contact Form
Maximum switching power
Contact rating
Maximum switching voltage Maximum switching current Maximum carrying current
Minimum contact ratings Initial contact resistance Contact material
Nominal operating Power
Non-latch type and double coil latch type
Single coil Latch type
Minimum operating Power
Non-latch type and double coil latch type
Single coil latch type
Operate time (excluding bounce) Release time (excluding bounce) Insulation resistance
Between open contacts Breakdown voltage Between adjacent contacts
Between coil and contact
Shock resistance
Vibration resistance
Ambient temperature Coil temperature rise
Noload Running specifications
Load
Weight
1
This value is a reference value in the resistance load. Minimum capacity changes depending on seitching frequency and environment temperature and the load.
2
Rise time : 10 µs, fall time : 160 µs
3
This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of operation by which a steady characteristic is maintained is 1 × 107 times.
2 form c 30 W (resistive) 62.5 VA (resistive) 220 Vdc 250 Vac 1 A 2 A 10 mVdc, 10 µA
1
50 m typ. (Initial) Silver alloy with gold alloy overlay 140 mW (3 to 12 V)
200 mW (24 V) 100 mW (3 to 12 V)
150 mW (24 V) 79 mW (3 to 12 V)
113 mW (24 V) 56 mW (3 to 12 V)
85 mW (24 V) Approximately 2 ms without diode
Approximately 1 ms without diode 1000 M at 500 Vdc 1000 Vac (for one minute)
1500 V surge (10 × 160 µs ∗2)
735 m / s2 (75 G) (misoperating) 980 m / s2 (100 G) (destructive failure)
10 to 55 Hz at double amplitude of 3 mm (20 G) (misoperating) 10 to 55 Hz, at double amplitude of 5 mm (30 G) (destructive failure)
–40°C to 85°C 18 degrees at nominal coil voltage 1 × 108 operations (Non-latch type) 1 × 107 operations (latch type) 50 Vdc 0.1 A (resistive), 1 × 106 operations at 85˚C, 2 Hz 10 Vdc 10 mA (resistive), 1 × 106 operations at 85˚C, 2 Hz Approximately 1.5 grams
3
3DATA SHEET ER0001EJ6V0DS00
PRODUCT LINEUP Non-latch Type
Nominal Coil
Voltage
(Vdc)
3
4.5 5 6
9 12 24
Coil
Resistance
() ±10 %
64.3 145 178 257 579
1028 2880
Must Operate
Voltage
(Vdc)
2.25
3.38
3.75
4.5
6.75 9
18
EA2 SERIES
at 20˚C
Must Release
Voltage
(Vdc)
0.3
0.45
0.5
0.6
0.9
1.2
2.4
Single-Coil Latch Type
Nominal Coil
Voltage
(Vdc)
3
4.5 5 6
9 12 24
Coil
Resistance
() ±10 %
90
202.5 250 360
810 1440 3840
Must Operate
Voltage
(Vdc)
2.25
3.38
3.75
4.5
6.75 9
18
Must Release
Voltage
(Vdc)
18
Double-Coil Latch Type ∗∗ (Can not be driven by revese polarity for reverse operation.)
Nominal Coil
Voltage
(Vdc)
3
4.5
5
6
9
12
24
Note Test by pulse voltage
∗∗ S : Set coil (pin No.1...
The latch type relays should be initalized at appointed position before using, and should be enegized to specific polanity by a bone polabity to avoid wrong operation. Any special coil requirement, please contact NEC for availability.
+ +
, pin No.5...
Coil
Resistance
() ±10 %
S 64.3 R 64.3 S 145 R 145 S 178 R 178 S 257 R 257 S 579 R 579 S 1028 R 1028 S 2880 R 2880
) R: Reset coil (pin No.10...
Must Operate
Voltage
(Vdc)
2.25 –
3.38 –
3.75 –
4.5 –
6.75 –
9
18
, pin No.6...
Must Release
Voltage
(Vdc)
18
)
at 20˚C
2.25
3.38
3.75
4.5
6.75 9
at 20˚C
2.25 –
3.38 –
3.75 –
4.5 –
6.75 –
9
4
DATA SHEET ER0001EJ6V0DS00
TYPICAL PERFORMANCE DATA
EA2 SERIES
SWITCHING CAPACITY
2.0
1.0
0.5
0.4
0.3
Switching Current (A)
0.2
30 100 200
Switching Voltage (V)
OPERATE TIME
2
1
DC Load (resistive) AC Load (resistive)
Operate Time
Bounce Time at Operate
0.25A
0.136A
250 Vdc 220 Vdc
COIL TEMPERATURE RISE
80
60
40
20
Coil Temperature Rise (˚C)
0
100 200 300 400
Applied Power (mW)
Release Time or
Bounce Time at Release (ms)
0 100 200 300 500400
Applied Power (mW)
RELEASE TIME WITHOUT DIODE
2
Release Time
1
Bounce Time at Release
Release Time or
Bounce Time at Release (ms)
0
100 200 300 500400
Applied Power (mW)
RUNNING SPECIFICATIONS (Noload)
Sample : EA2-5 n = 10 Load : None
5
4
Operate Voltage Release Voltage
3
2
1
Operate Voltage or
Release Voltage (V)
01
23
Number of Operations ( × 10
RELEASE TIME WITH DIODE
Release Time
2
1
Release Time or
Bounce Time at Release (ms)
0
100 200 300 500400
Bounce Time at Release
Applied Power (mW)
Temperature : 85˚C Drive : 5 Vdc, 10 Hz 50% duty
1000
500
Make contact Break contact
300 200
100
50 30
20
Contact Resistance (m)
10
510
6
operations) Number of Operations ( × 106 operations)
01
23 5 10
5DATA SHEET ER0001EJ6V0DS00
MAGNETIC INTERFERENCE
EA2 SERIES
50 40 30 20 10
0
–10 –20 –30 –40
Drift of Operate Voltage (%)
–50
ON
ON
Layout Layout Layout Layout
I II III IV
ON ON ON
I II III IV V
OFF OFF
ON
ON
OFF OFF OFF
Max.
Min.
VI
OFF
OFF
Sample
50 40 30 20 10
0 –10 –20 –30 –40
Drift of Release Voltage (%)
–50
Max.
Min.
I
II III IV V VI
LayoutLayout
2.54
2.54
PACKAGE
Dimensions of Relay Tube (Unit : mm) 40 pieces / Tube
Outline of Package
Layout V
(2.5)
(0.5 t)
Layout VI
Material : Polyvinyl chloride
+
13.7 0.3
+
(6.2)
12.0 0.3
(4.5)
Rubber stopper (Red) Rubber stopper (Green)
(4.6)
(auti-static treated)
586 1
Mounting Layout (mm)
+
( ) Reference
Index Mark
6
DATA SHEET ER0001EJ6V0DS00
EA2 SERIES
GUIDE TO APPLICATIONS
1. When connecting coils, refer to the pin configuration to prevent misoperation or malfunction.
2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state.
3. Soldering should be done at 250˚C within 10 sec.
4. Ultrasonic cleaning is not recommended to keep reliable contact performance. Alcohol-based solvents are available as proper solvents.
5. Pressurized stress on the relay cover is not favorable to keep reliable operation of the relay during operation.
µ
6. Minimum contact load of the relay is 10 mV, 10 This value is a reference value in the resistance load.
Minimum capacity changes depending on swiching frequency and environment temperature and the load.
A.
7DATA SHEET ER0001EJ6V0DS00
EA2 SERIES
No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellec­tual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. While NEC Corporation has been making continuous effort to enhance the reliability of its electronic components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC electronic component, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti­failure features. NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment, au-
dio and visual equipment, home electronic appliances, machine tools, personal electronic equip­ment and industrial robots
Special: T ransportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically de­signed for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. Anti-radioactive design is not implemented in this product.
Loading...