Motorola EX-3524, EX-3548 Installation Manual

Page 1
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
INSTALLATION GUIDE
Page 2
2 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies, Inc., a Zebra Technologies company.
© 2015 Symbol Technologies, Inc.
Page 3
Installation Guide 3
1.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Document Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 Selecting a Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.0 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1 Physical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2 Environmental Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4 Power Cord Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.4.1 Power Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.5 Switch Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2.1 Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.2 10/100/1000Base-T RJ-45 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.3 Gigabit SFP Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.4 Mode Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.5 Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.6 System LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.7 Reset Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.8 Ground Point. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2.9 AC Power Socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.6 LED Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.6.1 System Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.6.2 Port Status LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.0 Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 Rack Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2 Shelf or Desktop Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.3 Power and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Page 4
4 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
3.4 Port Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.1 Installing SFP Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.2 Connecting Twisted-Pair Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4.3 Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4.4 Power-over-Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.4.5 Connecting to SFP Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.0 Switch Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.1 Connecting to the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.2 Resetting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5.0 Regulatory Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.1 Radio Frequency Interface Requirements - FCC. . . . . . . . . . . . . . . . . . . . . . . . . 28
5.2 Radio Frequency Interface Requirements - Canada. . . . . . . . . . . . . . . . . . . . . . 28
5.3 CE Marking and European Economic Area (EAA). . . . . . . . . . . . . . . . . . . . . . . . 28
5.4 Statement of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.5 PSE Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.6 Power Cord Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.7 Waste Electrial and Electronic Equipment (WEEE) . . . . . . . . . . . . . . . . . . . . . . 33
6.0 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.1 Customer Support Web Sites. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.2 Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Page 5
Installation Guide 5
!
!

1 Introduction

The EX-3524 and EX-3548 are Gigabit Ethernet Layer 2 switches with either 24 or 48 10/100/1000-BASE-T ports, and four Small Form Factor Pluggable (SFP) transceiver slots for fiber connectivity. The switches are built with leading-edge technology to deliver reliable high-performance connectivity for your data network.
All of the 10/100/1000 Mbps ports on the switches support both the IEEE 802.3af and IEEE 802.3at-2009 PoE standards.
Each switch also includes an SNMP-based management agent, which provides both in-band and out-of-band access for managing the switch.
This document is written for the professional installer deploying EX-3524 and EX-3548 switches.
1.1 Unpacking
Verify that you have the equipment listed below:
EX-3524 or EX-3548 switch
Rack Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch
Console cable— RJ-45 to DB-9
Four adhesive foot pads
EX-3524/EX-3548 Layer 2 Gigabit Ethernet Switches Installation Guide (this document)
Inspect the equipment for damage. If you are missing any equipment or if you find any damaged equipment, contact Support immediately. Contact information is available at www.zebra.com/support
.
1.2 Document Conventions
The following graphical alerts are used in this document to indicate notable situations:
NOTE Tips, hints, or special requirements that you should take note of.
CAUTION Care is required. Disregarding a caution can result in data loss or
equipment malfunction.
WARNING! Indicates a condition or procedure that could result in personal injury or
equipment damage.
Page 6
6 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
1.3 Warnings
Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source.
Remove jewelry and watches before installing this equipment.
Verify any device connected to this unit is properly wired and grounded.
Connect all power cords to a properly wired and grounded electrical circuit.
Verify the electrical circuits have appropriate overload protection.
There is a risk of explosion if the battery supplied with this product is replaced with an incorrect type of battery. Dispose of used batteries according to the instructions.
•Use an Uninterruptible Power Supply (UPS) that supports the EX-3524/EX-3548 switch power rating. Not using a UPS can result in data loss or equipment damage due to a power surge or power failure.
Verify that the power connector and socket are accessible at all times during the operation of the equipment.
Do not work with power circuits in dimly lit spaces.
Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that could cause a power surge.
Verify there is adequate ventilation around the device, and ambient temperatures meet equipment operation specifications.
This product is designed for in building installation only and is not intended to be connected to exposed (outside plant) networks.
This product uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on.
When selecting a fiber SFP device, considering safety, please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product. You must also use an approved Laser Class 1 SFP transceiver.
Use only twisted-pair cables that conform to FCC standards with RJ-45 connectors.
1.4 Site Preparation
Consult your site survey and network analysis reports to determine specific equipment placement, power drops, and so on.
Assign installation responsibility to the appropriate personnel.
Identify where all installed components are located.
Verify appropriate rack mounting requirements, as required.
Provide a sufficient number of power drops for your equipment.
Ensure adequate, dust-free ventilation to all installed equipment.
Identify and prepare Ethernet and console port connections.
Verify that cable lengths are within the maximum allowable distances for optimal signal transmission.
Verify that the device is powered through an Uninterruptible Power Supply (UPS).
Page 7
Installation Guide 7
1.5 Selecting a Site
Switch units can be mounted in a standard 19 inch equipment rack or on a flat surface. Be sure to follow the guidelines listed below when choosing a site:
Locate the switch unit at the center of all devices you want to link and near a power outlet.
Maintain a temperature range within 0 non-condensing.
Provide adequate space (approximately 2 inches) on all sides for proper air flow.
Confirm access for installing, cabling, and maintaining all devices.
Install the switch unit so that status LEDs are clearly visible.
Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards.
Ensure that twisted-pair cables are always routed away from power lines, fluorescent lighting fixtures, and other sources of electrical interference, such as radios and transmitters.
Ensure that the unit is connected to a separate grounded power outlet that provides 100 to 240VAC and 50 to 60Hz power levels.
Ensure that the unit is within 6.6 ft / 2m of each device that is powered from an independent circuit breaker.
Use of a filter or circuit breaker is recommended.
° to 50° C / 32° to 122° F and humidity range within 10% to 90%
Page 8
8 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch

2 Specifications

2.1 Physical Specifications
Form factor 1U rack mount
Dimensions (WxDxH)
EX-3524: 44.0 x 28.0 x 4.4 cm (17.32 x 11.00 x 1.73 in) EX-3548: 44.0 x 40.9 x 4.4 cm (17.32 x 16.10 x 1.73 in)
Weight EX-3524: 3.6 kg (7.83 lb)
EX-3548: 6.6 Kg (14.55 lb)
2.2 Environmental Specifications
Operating Temperature
Operating Humidity 10% to 90% (non-condensing)
Operating altitude EX-3524: 4004 m (13,136 ft)
Storage Temperature -40° C to 70° C (-40° F to 158° F)
Storage Humidity 10% to 90% (non-condensing)
Storage Altitude 4572 m (15,000 ft)
0° C to 50° C (32° F to 122° F)
EX-3548:2000 m (6, 561 ft)
2.3 Electrical Specifications
AC input voltage EX-3524: AC 100-240 V, 50-60 Hz, 6 A
EX-3548: AC 100-240 V, 50-60 Hz, 12 A
PoE power output EX-3524: Up to 370 W
EX-3548: Up to 740 W
Page 9
Installation Guide 9
2.4 Power Cord Specifications
A power cord is not supplied with the EX-3524/EX3548 switch. Use only a correctly rated power cord certified (as appropriate) for the country of operation.
2.4.1 Power Protection
If possible, use a circuit dedicated to data processing equipment. Commercial electrical contractors are familiar with wiring for data processing equipment and can help with the load balancing of these circuits.
Install surge protection. Be sure to use a surge protection device between the electricity source and the EX-3524/EX-3548 switch.
Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased.
2.5 Switch Description
The EX-3524 (top) and EX-3548 (bottom) are shown in the drawings below. The switches consist of several key hardware components. This manual describes each specific component, or related components, together with their installation requirements and procedures.
Page 10
10 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
2.5.1 Port LEDs
For information on port status LED indicators, see Port Status LEDs on page 13.
2.5.2 10/100/1000BASE-T RJ-45 Ports
The switch contains 24 10/100/1000BASE-T RJ-45 ports that support 10/100/1000BASE-T copper links to other devices. For more information, see Connecting Twisted-Pair Cables on page 21.
2.5.3 Gigabit SFP Slots
The switch contains four Small Form Factor Pluggable (SFP) transceiver slots that operate up to Gigabit full duplex. For more information, see Connecting to SFP Ports on page 23.
2.5.4 Mode Button
Pressing the Mode button on the front panel will change the Diag LED to display PoE status. For more information, see LED Codes on page 12.
2.5.5 Console Port
The RJ-45 connector on the front panel far right side that is labeled “Console” provides an out-of-band serial connection to a terminal or a PC running terminal emulation software. The port can be used for performing switch monitoring and configuration. For more information, see Connecting to the Console Port on page 25.
2.5.6 System LEDs
For information on system status LED indicators, see LED Codes on page 12.
2.5.7 Reset Button
Pressing the reset button on the rear panel causes the switch to execute a hard reset. For more information, see Resetting the Switch on page 26.
Page 11
Installation Guide 11
2.5.8 Ground Point
The switch should be connected to ground using this screw connection. For more information on how to connect ground to the switch, see Power and Grounding on page 18.
2.5.9 AC Power Socket
The switch requires a 100-240 VAC, 50-60 Hz AC power source. For more information on the switch power input, how to connect it, and how to power-on the switch, see Power and Grounding on page 18.
Page 12
12 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
2.6 LED Codes
2.6.1 System Status LEDs
The diagnostic and power LEDs located on the front panel are shown below and described in the following table:
LED Condition Status
DIAG Green Solid
Amber Solid Blinking Amber Blinking Amber and Green
PWR Green Solid
Off
System diagnostic test completed successfully System diagnostic test in progress or PoE button pressed System fault detected System booting up
Internal power operating normally. No AC power is connected or the internal power supply has
failed.
Page 13
Installation Guide 13
2.6.2 Port Status LEDs
The switch includes LEDs for each port to indicate link status and network activity. The port LEDs are shown below and described in the following table:
LED Condition Status
1000BASET RJ-45 Ports (1 - 24 or 1 - 48)
Link/Activity On/Blinking Amber
On/Blinking Green Off
PoE Status (mode button is pressed)
Gigabit SFP Ports (25-28 or 49-52)
Link/Activity On/Blinking Green
On Amber Off
Off
Port has a valid 10/100 Mbps link. Blinking indicates traffic on the port. Port has a valid 1000 Mbps link. Blinking indicates traffic on the port. The link is down.
A PoE device is connected. No PoE device is connected.
Port has a valid 1000 Mbps link (high speed). Blinking indicates traffic on the port.
The link is down.
Page 14
14 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch

3 Hardware Installation

The switch is designed to be installed in either a standard 19-inch equipment rack or simply placed on a suitable desktop or shelf surface. If you will mount your switch in a rack then plan your rack installation and install the switch chassis in the rack. Be sure to take into account switch cooling requirements.
Observe the following guidelines when selecting a location for switch installation:
Maintain a temperature of 0
Provide space for adequate airflow.
Status LEDs should be clearly visible.
Ensure that twisted-pair cables are always routed away from the power lines, fluorescent lighting fixtures and other sources of electrical interference.
° to 50° C (32° to 122° F) and non-condensing humidity within 10% to 95%.
3.1 Rack Mount Installation
To install the switch in a rack:
1. Attach the brackets to the switch using the screws provided in the Bracket Mounting Kit.
Page 15
Installation Guide 15
2. Use the supplied rack mounting screws to secure the switch in the rack.
Page 16
16 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
3. Connect an external AC power source to the AC power socket.
4. Verify basic switch operation by observing the system LEDs. For normal operation, both the DIAG and PWR LEDs should be solid green.
Page 17
Installation Guide 17
5. Install the SFP transceivers and connect the cables to the port interfaces.
• For RJ-45 ports, use 100-ohm category 3 or better Ethernet cable for 10BASE-T connections, use 100-ohm category 5 or better Ethernet cable for 100BASE-TX and 1000BASE-T connections.
• Install SFP transceivers and then connect fiber optic cabling to the transceiver ports.
• Status LEDs should be clearly visible.
• Ensure that twisted-pair cables are always routed away from the power lines, fluorescent lighting fixtures and other sources of electrical interference.
To make basic configuration changes before connecting the switch to the network, see Switch Management on page 25.
Page 18
18 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
3.2 Shelf or Desktop Installation
The switch can be installed on any flat surface such as a desktop or shelf. To mount the switch on a flat surface:
1. Attach the four adhesive feet to the bottom of the switch.
2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper airflow.
3. If installing multiple switches, attach four adhesive feet to each switch. Place each device squarely on top of the one below, in any order.
3.3 Power and Grounding
The switches require power from an external AC power supply that can provide 100 to 240 VAC, 50-60 Hz. A standard AC power socket is located on the rear panel EX-3524 (left) and EX-3548 (right) of the each switch.
Page 19
Installation Guide 19
!
!
The rear panel of the switch chassis includes a single hole grounding terminal. It must be connected to ground to ensure proper operation and to meet electromagnetic interference (EMI) and safety requirements.
To ground the switch chassis:
1. Ensure the rack on which the switch is to be mounted is properly grounded and in compliance with ETSI ETS 300 253.
2. Ensure there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).
3. Disconnect all power cables to the switch.
4. The switch chassis is connected internally to 0 V. This circuit is connected to the single-hole grounding terminal on the rear panel of the switch. The surface area around this terminal is not painted in order to provide for a good connection.
5. Attach a 6 AWG stranded copper wire to the grounding terminal on the switch.
6. Attach the grounding wire to the ground point on the rack.
CAUTION The earth connection should not be removed unless all power supply
connections have been disconnected.
Page 20
20 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
3.4 Port Connecctions
3.4.1 Installing SFP Transceivers
The switch provides slots for optional (not provided) SFP transceivers. The supported transceiver types are listed below:
1000BASE-SX
1000BASE-LX
1000BASE-LH
1000BASE-FX
1000BASE-T
NOTE SPF transceivers are hot-swappable. The switch does not need to be
powered off before installing or removing the transceiver.
To install a SFP transceiver:
1. Consider network and cabling requirements to select an appropriate transceiver type also compatible with the switch transceiver support.
2. If the SFP slot is covered with a rubber protective cap, remove the cap and keep it for later replacement.
3. Insert the transceiver with the optical connector facing outward and the slot connector facing down. Note that SFP transceivers are keyed so they can only be installed in the correct orientation.
Page 21
Installation Guide 21
4. Slide the transceiver into the slot until it clicks into place. If you do not immediately connect a cable to the port, use a rubber protective cap to keep the transceiver optics clean.
NOTE To remove a transceiver, disconnect the network cable then pull the tab
to remove the transceiver from the slot.
3.4.2 Connecting Twisted-Pair Cables
The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration, which enables you to use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, routers, or hubs).
The connection requires an unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable with RJ-45 connectors at both ends.
Cable Type Maximum Cable Length Connector Type
100BASE-T Category 5, 5e or 100-ohm UTP or STP
100BASE-TX Category 5 or better 100-ohm UTP or STP
10BASE-T Category 3 or better 100-ohm UTP
100 m (328 ft) RJ-45
100 m (328 ft) RJ-45
100 m (328 ft) RJ-45
To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T, 100BASE-TX, or 1000BASE-T operation. Check the following criteria against the current installation of your network:
Cable type: UTP or STP cables with RJ-45 connectors; Category 5, 5e or better cable for 1000BASE-T connections, Category 5 or better for 100BASE-TX connections, and Category 3 or better for 10BASE-T connections.
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic fields from data based network wiring
Safe connections with no damaged cables, connectors or shields
3.4.3 Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, Category 5e (enhanced Category 5) or Category 6 cable should be used. The Category 5e and Category 6 specifications include test parameters that are only recommendations for Category 5. Therefore, the first step in
Page 22
22 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
preparing existing Category 5 cabling for running 1000BASE-T is a simple test of the cable installation to be sure that it complies with the IEEE 802.3-2008 standards.
3.4.4 Power-over-Ethernet
The switch supports both IEEE 802.3af and IEEE 802.3at-2009 PoE standards that enable DC power to be supplied from the switch’s RJ-45 copper ports to connected devices by utilizing certain pairs of the connecting Ethernet cable.
For the EX-3524, the total PoE power delivered by all ports cannot exceed the 390 W power budget. This means up to 12 ports can supply a maximum 30 W of power simultaneously to connected devices, or all 24 ports can supply a maximum of 15.4 W.
For the EX-3548, the total PoE power delivered by all ports cannot exceed the 779 W power budget. This means up to 24 ports can supply a maximum 30 W of power simultaneously to connected devices, or all 48 ports can supply a maximum of 15.4 W simultaneously.
Any PoE-compliant device attached to a port can directly draw power from the switch over the Ethernet cable without requiring its own separate power source. This capability gives network administrators centralized power control for devices such as IP phones and wireless access points, which translates into greater network availability.
To connect 100BASE-T cables to RJ-45 ports:
1. Consider network and cabling requirements to select an appropriate transceiver type that is also compatible with the switch transceiver support.
2. Attach the other end to an available port on the switch. Ensure each twisted pair cable does not exceed 100 meters (328 ft) in length.
3. As each connection is made, the Link LED (on the switch) corresponding to each port will turn on green to indicate that the connection is valid.
Page 23
Installation Guide 23
3.4.5 Connecting to SFP Ports
The switch provides four ports for SFP-compliant fiber-optic transceivers. All 1000BASE fiber optic ports operate at 1 Gbps full duplex. The 100BASE fiber optic ports operate at 100 Mbps full duplex.
Cable Type
100BASE-SX
62.5/125 micron multimode
50/125 micron multimode
100BASE-LX 9/125 micron single mode
10BASE-LH 9/125 micron single mode
NOTE
The length of fiber optic cable for a single switched link should not exceed the relevant specified standards. However, power budget constraints should also be considered when calculating the maximum fiber optic cable length for a a particular link. Maximum distances may vary for SFP vendors.
WARNING! This switch uses lasers to transmit signals over fiber optic cable. The
lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on. When selecting a fiber SFP device, considering safety, please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product. You must also use an approved Laser Class 1 SFP transceiver.
Fiber
Bandwidth
160 MHz.km 200 MHz/km 400 MHz/km 500 MHz/km
N/A 2 m - 10 km (7 ft- 6.2
N/A 2 m - 80 km (7 ft- 50
Maximum Cable
Length Connector Type
2-220 m (7-722 ft) 2-275 m (7-902 ft) 2-500 m (7-1641 ft) 2-550 m (7-1805 ft)
miles)
miles)
LC
LC
LC
To connect cables to SFP transceiver ports:
1. Remove and keep the fiber port’s rubber plug. When not connected to a fiber cable, the rubber plug should be replaced to protect the optics.
2. Check that the fiber terminators are clean. You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol. Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable and lead to degraded performance on the port.
Page 24
24 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
3. Connect one end of the cable to the SFP port on the switch and the other end to the SFP port on the other device. Since SFP connectors are keyed, the cable can be attached in only one orientation.
4. As a connection is made, check the Link LED on the switch to validate the connection is valid.
NOTE Ensure cables are properly secured and route them away from the switch
without exceeding the minimum bending radius for fiber cables (typically a few inches). Use cable ties to bundle cables together and secure coiled loops of excess cable. Do not let cables hang free supporting their own weight or pull in any way that puts stress on the connectors.
Page 25
Installation Guide 25

4 Switch Management

The RJ-45 Console port on the front panel of the switch is used to connect a console device to the switch for out-of-band console configuration. The console device can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal. A console cable is supplied with the switch for connecting to a PC’s RS-232 serial DB-9 DTE (COM) port.
NOTE To connect to notebooks or other PCs without a DB-9 COM port, use a
USB-to-male DB-9 adapter cable (not supplied).
The serial port default settings are as follows:
Default Baud rate - 115200 bps
CharacterSize - 8 Characters
Parity - None
Stop bit - One
Data bits - 8
Flow control - None
4.1 Connecting to the Console Port
To connect to the console port:
1. Connect one end of the included RJ-45 to DB-9 serial cable to a DB-9 COM port connector on the network management computer.
2. Plug in the RJ-45 end of the serial cable to the Console port on the switch.
Page 26
26 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
3. Configure the PC’s COM port required settings using VT-100 terminal emulator software (such as HyperTerminal) running on the management PC. The switch’s default console port settings are:
• 115200 bps, 8 data bits, 1-stop bit and no parity
4. Log in to the command-line interface (CLI) using one of the default user login settings:
•username: admin
• password: admin123
or
•username: guest
• password: guest
NOTE The guest default user login will only allow a user to view switch
parameter data.
For a detailed description of connecting to the console and using the switch’s command line interface (CLI), refer to the CLI Reference Guide.
4.2 Resetting the Switch
The Reset button, located on the rear panel of the switch, can be used to restart the device and set the configuration back to either the current saved configuration file or the factory default settings.
Press the reset button from 3 to 6 seconds to restart the system software using the current saved configuration file. Press the reset button for 6 seconds or more to restart the system software using the factory default settings.
Page 27
Installation Guide 27
Press Button Duration Result
Less than 3 seconds No change to settings
From 3 seconds to less than 6 seconds Switch reboots using saved configuration file
6 seconds or greater Switch reboots using factory default settings
Page 28
28 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch

5 Regulatory Overview

This guide applies to the following model numbers: EX-3524 and EX-3548.
All Zebra devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required.
Local language translations are available at the following Website: www.zebra.com/support
Any changes or modifications to Zebra equipment, not expressly approved by Zebra, could void the user’s authority to operate the equipment.
WARNING! This product is designed and approved for in-building installation only
and is not intended for exposed (outside plant) networks.
.
5.1 Radio Frequency Interference Requirements - FCC
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
5.2 Radio Frequency Interference Requirements - Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
5.3 CE Marking and European Economic Area (EEA)
WARNING! This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
5.4 Statement of Compliance
Zebra hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC and 2011/65/EU. A Declaration of Conformity may be obtained from. A Declaration of Conformity may be obtained from www.zebra.com/doc
.
Page 29
Installation Guide 29
Japan Voluntary Control Council for Interference (VCCI) Class A ITE
Korea Warning Statement for Class A ITE
Chinese Warning Statement for Class A ITE
5.5 PSE Alarm
5.6 Power Cord Safety
Please read the following safety information carefully before installing the switch:
Warning: Installation and removal of the unit must be carried out by qualified personnel only. The unit must be connected to an earthed (grounded) outlet to comply with international safety standards. Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection. The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.
The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.
Page 30
30 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).
† Impédance à la terre
Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:
Power Cord Set
U.S.A. and Canada The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor The cord set must have a rated current capacity of at least 10 A The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125 V)
configuration.
Denmark The supply plug must comply with Section 107-2-D1, Standard DK2-1a or DK2-5a.
Switzerland The supply plug must comply with SEV/ASE 1011.
U.K. The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fuse which complies
with BS1362. The main cord must comply with IEC 60227 (designation 60227 IEC 52).
Europe The supply plug must comply with CEE7/7 (“SCHUKO”).
The mains cord must comply with IEC 60227 (designation 60227 IEC 52). IEC-320 receptacle.
Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:
Avertissement: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié. Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).
Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité.
Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entrée d’appareil EN 60320/IEC 320.
Page 31
Installation Guide 31
La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son cordon électrique au niveau de cette prise.
L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec raccordement direct à la terre (masse).
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Etats-Unis et Canada
Danemark La prise mâle d’alimentation doit respecter la section 107-2 D1 de la norme DK2 1a ou DK2 5a.
Suisse La prise mâle d’alimentation doit respecter la norme SEV/ASE 1011.
Europe La prise secteur doit être conforme aux normes CEE 7/7 (“SCHUKO”)
Les spécifications minimales pour un cable flexible sont AWG No. 18, ouAWG No. 16 pour un cable de
longueur inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs Le cordon doit être en mesure d’acheminer un courant nominal d’au moins 10 A. La prise femelle de branchement doit être du type à mise à la terre (mise à la masse) et respecter la configuration NEMA 5-15P (15 A, 125 V).
Le cordon d'alimentation doit être conforme à la norme IEC 60227 (IEC 60227 désignation 52)
Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen:
Warnung: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen.
Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose angeschlossen werden.
Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die internationalen Sicherheitsnormen erfüllt.
Der Gerätestecker (der Anschluß an das Gerät, nicht der Wandsteckdosenstecker) muß einen gemäß EN 60320/IEC 320 konfigurierten Geräteeingang haben.
Page 32
32 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Etats-Unis et Canada
Danemark La prise mâle d’alimentation doit respecter la section 107-2 D1 de la norme DK2 1a ou DK2 5a.
Schweiz Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalten.
Europe Das Netzkabel muss mit IEC 60227 (IEC 60227 entsprechen Bezeichnung 52)
Le cordon doit avoir reçu l’homologation des UL et un certificat de la CSA. Les spécifications minimales pour un cable flexible sont AWG No. 18, ouAWG No. 16 pour un cable
de longueur inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs Le cordon doit être en mesure d’acheminer un courant nominal d’au moins 10 A. La prise femelle de branchement doit être du type à mise à la terre (mise à la masse) et respecter la configuration NEMA 5-15P (15 A, 125 V).
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
Page 33
Installation Guide 33
5.7 Waste Electrical and Electronic Equipment (WEEE)
English: For EU Customers: All products at the end of their life must be returned to Zebra for recycling. For information on how to return product, please go to: www.zebra.com/weee Français: Clients de l'Union Européenne: Tous les produits en fin de cycle de vie doivent être retournés à Zebra pour recyclage. Pour de plus amples informations sur le retour de produits, consultez: www.zebra.com/weee Español: Para clientes en la Unión Europea: todos los productos deberán entregarse a Zebra al final de su ciclo de vida para que sean reciclados. Si desea más información sobre cómo devolver un producto, visite:
www.zebra.com/weee.
Български: За клиенти от ЕС: След края на полезния им живот всички продукти трябва да се връщат на Zebra за рециклиране. За информация относно връщането на продукти, моля отидете на адрес:
www.zebra.com/weee
Deutsch: Für Kunden innerhalb der EU: Alle Produkte müssen am Ende ihrer Lebensdauer zum Recycling an Zebra zurückgesandt werden. Informationen zur Rücksendung von Produkten finden Sie unter
www.zebra.com/weee
Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Zebra al fine di consentirne il riciclaggio. Per informazioni sulle modalità di restituzione, visitare il seguente sito Web: www.zebra.com/weee
Português: Para clientes da UE: todos os produtos no fim de vida devem ser devolvidos à Zebra para reciclagem. Para obter informações sobre como devolver o produto, visite: www.zebra.com/weee. Nederlands: Voor klanten in de EU: alle producten dienen aan het einde van hun levensduur naar Zebra te worden teruggezonden voor recycling. Raadpleeg www.zebra.com/weee terugzenden van producten. Polski: Klienci z obszaru Unii Europejskiej: Produkty wycofane z eksploatacji nale¿y zwróciæ do firmy Zebra w celu ich utylizacji. Informacje na temat zwrotu produktów znajduj¹ siê na stronie internetowej
www.zebra.com/weee.
Čeština: Pro zákazníky z EU: Všechny produkty je nutné po skonèení jejich životnosti vrátit spoleènosti Zebra k recyklaci. Informace o zpùsobu vrácení produktu najdete na webové stránce: www.zebra.com/weee
Eesti: EL klientidele: kõik tooted tuleb nende eluea lõppedes tagastada taaskasutamise eesmärgil Zebra'ile. Lisainformatsiooni saamiseks toote tagastamise kohta külastage palun aadressi: www.zebra.com/weee Magyar: Az EU-ban vásárlóknak: Minden tönkrement terméket a Zebra vállalathoz kell eljuttatni újrahasznosítás céljából. A termék visszajuttatásának módjával kapcsolatos tudnivalókért látogasson el a www.zebra.com/weee weboldalra. Svenska: För kunder inom EU: Alla produkter som uppnått sin livslängd måste returneras till Zebra för återvinning. Information om hur du returnerar produkten finns på www.zebra.com/weee Suomi: Asiakkaat Euroopan unionin alueella: Kaikki tuotteet on palautettava kierrätettäväksi Zebra-yhtiöön, kun tuotetta ei enää käytetä. Lisätietoja tuotteen palauttamisesta on osoitteessa www.zebra.com/weee Dansk: Til kunder i EU: Alle produkter skal returneres til Zebra til recirkulering, når de er udtjent. Læs oplysningerne om returnering af produkter på: www.zebra.com/weee.
Ελληνικά: Για πελάτες στην Ε.Ε.: Όλα τα προϊόντα, στο τέλος της διάρκειας ζωής τους, πρέπει να επιστρέφονται στην Zebra για ανακύκλωση. Για περισσότερες πληροφορίες σχετικά με την επιστροφή ενός προϊόντος, επισκεφθείτε τη διεύθυνση www.zebra.com/weee
.
.
.
στο ∆ιαδίκτυο.
.
.
. voor meer informatie over het
.
.
.
.
Page 34
34 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch
Malti: Għal klijenti fl-UE: il-prodotti kollha li jkunu waslu fl-aħħar tal-ħajja ta' l-użu tagħhom, iridu jiġu rritornati għand Zebra għar-riċiklaġġ. Għal aktar tagħrif dwar kif għandek tirritorna l-prodott, jekk jogħġbok żur:
www.zebra.com/weee
Românesc: Pentru clienţii din UE: Toate produsele, la sfârşitul duratei lor de funcţionare, trebuie returnate la Zebra pentru reciclare. Pentru informaţii despre returnarea produsului, accesaţi: www.zebra.com/weee
Slovenski: Za kupce v EU: vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Zebra za reciklažo. Za informacije o vračilu izdelka obiščite: www.zebra.com/weee
Slovenčina: Pre zákazníkov z krajín EU: Všetky výrobky musia byť po uplynutí doby ich životnosti vrátené spoločnosti Zebra na recykláciu. Bližšie informácie o vrátení výrobkov nájdete na: www.zebra.com/weee. Lietuvių: ES vartotojams: visi gaminiai, pasibaigus jų eksploatacijos laikui, turi būti grąžinti utilizuoti į kompaniją „Zebra“. Daugiau informacijos, kaip grąžinti gaminį, rasite: www.zebra.com/weee Latviešu: ES klientiem: visi produkti pēc to kalpošanas mūža beigām ir jānogādā atpakaļ Zebra otrreizējai pārstrādei. Lai iegūtu informāciju par produktu nogādāšanu Zebra, lūdzu, skatiet: www.zebra.com/weee
Türkçe: AB Müşterileri için: Kullanım süresi dolan tüm ürünler geri dönüştürme için Zebra'ya iade edilmelidir. Ürünlerin nasıl iade edileceği hakkında bilgi için lütfen şu adresi ziyaret edin: www.zebra.com/weee
Turkish WEEE Statement of Compliance
EEE Yönetmeliğine Uygundur
.
.
.
.
.
.
Page 35
Installation Guide 35

6 Support

If you have a problem with your equipment, contact support for your region.
Contact information is available at: www.zebra.com/support
When contacting support, please provide the following information:
• Serial number of the unit
• Model number or product name
• Software type and version number
Support responds to calls by e-mail, telephone, or fax within the time limits set forth in support agreements. If you purchased your product from a business partner, contact that business partner for support.
.
6.1 Customer Support Web Sites
Support located at: www.zebra.com/support provides information and online assistance including developer tools, software downloads, product manuals and online repair requests.
6.2 Manuals
Documentation is available at: www.zebra.com/support.
Page 36
Zebra Technologies Corporation Lincolnshire, IL 60069 USA
Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies, Inc., a Zebra Technologies company. © 2015 Symbol Technologies, Inc.
MN001686A01 Revision A April 2015
Loading...