Safety Controller Setting and Monitoring Tool
Operating Manual
-WS0-CPU0
-WS0-CPU1
-WS0-CPU3
-SW1DNN-WS0ADR-B
This document is protected by the law of copyright, whereby all rights established
therein remain with the company Mitsubishi Electric Corporation. Reproduction of this
document or parts of this document is only permissible within the limits of the legal
determination of Copyright Law. Alteration or abridgement of the document is not
permitted without the explicit written approval of the company Mitsubishi Electric
Corporation.
Precautions regarding warranty and specifications
MELSEC-WS series products are jointly developed and manufactured by Mitsubishi
and SICK AG, Industrial Safety Systems, in Germany.
Note that there are some precautions regarding warranty and specifications of
MELSEC-WS series products.
<Warranty>
The gratis warranty term of the product shall be for one (1) year after the date of
delivery or for eighteen (18) months after manufacturing, whichever is less.
The onerous repair term after discontinuation of production shall be for four (4)
years.
Mitsubishi shall mainly replace the product that needs a repair.
It may take some time to respond to the problem or repair the product depending on
the condition and timing.
<Specifications>
General specifications of the products differ.
MELSEC-WS MELSEC-QMELSEC-QS
Operating ambient temperature -25 to 55°C*1 0 to 55°C 0 to 55°C
Operating ambient humidity 10 to 95%RH 5 to 95%RH
Storage ambient temperature -25 to 70°C -25 to 75°C -40 to 75°C
Storage ambient humidity 10 to 95%RH 5 to 95%RH
*1 When the WS0-GCC100202 is included in the system, operating ambient temperature will
be 0 to 55 °C.
5 to 95%RH
%RH
5 to 95
EMC standards that are applicable to the products differ.
MELSEC-WS MELSEC-Q, MELSEC-QS
EMC standards EN61000-6-2, EN55011 EN61131-2
SAFETY PRECAUTIONS
(Read these precautions before using this product.)
Before using this product, please read this manual and the relevant manuals carefully and pay full
attention to safety to handle the product correctly.
In this manual, the safety precautions are classified into two levels: "WARNING" and "CAUTION".
Under some circumstances, failure to observe the precautions given under "CAUTION" may lead to
serious consequences.
Observe the precautions of both levels because they are important for personal and system safety.
Make sure that the end users read this manual and then keep the manual in a safe place for future
reference.
[Design Precautions]
WARNING
When the MELSEC-WS safety controller detects a fault in the external power supply or itself, it
turns off the outputs. Configure an external circuit so that the connected devices are powered off
according to the output status (off) of the MELSEC-WS safety controller. Incorrect configuration
may result in an accident.
When a load current exceeding the rated current or an overcurrent caused by a load short-circuit
flows for a long time, it may cause smoke and fire. To prevent this, configure an external safety
circuit, such as a fuse.
For safety relays, configure an external circuit using a device such as a fuse or breaker to protect a
short-circuit current.
When changing data and operating status, and modifying program of the running MELSEC-WS
safety controller from the PC, configure a safety circuit in the sequence program or external to the
MELSEC-WS safety controller to ensure that the entire system operates safely.
Before operating the MELSEC-WS safety controller, read the relevant manuals carefully and
determine the operating procedure so that the safety can be ensured.
Furthermore, before performing online operations for the MELSEC-WS safety controller from the
PC, determine corrective actions to be taken for communication errors caused by failure such as a
poor contact.
Create an interlock program using a reset button to prevent the MELSEC-WS safety controller from
restarting automatically after the safety function is activated and the safety controller turns off the
outputs.
1
CAUTION
Ensure that an entire system using the MELSEC-WS safety controller meets the requirements for
the corresponding safety category.
The life of safety relays in the safety relay output module depends on the switching condition
and/or load. Configure a system satisfying the number of switching times of the safety relays in
the module.
Do not install the communication cables together with the main circuit lines or power cables. Keep
a distance of 100 mm or more between them.
Failure to do so may result in malfunction due to noise.
If a mechanical switch such as a relay is connected to an input terminal of a safety I/O module,
consider contact bounce.
Observe the protective notes and measures.
Observe the following items in order to ensure proper use of the MELSEC-WS safety controller.
When mounting, installing and using the MELSEC-WS safety controller, observe the standards
and directives applicable in your country.
The national/international rules and regulations apply to the installation, use and periodic
technical inspection of the MELSEC-WS safety controller, in particular.
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
Provision and Use of Work Equipment Directive 89/655/EC
Low-Voltage Directive 2006/95/EC
The work safety regulations/safety rules
Manufacturers and owners of the machine on which a MELSEC-WS safety controller is used
are responsible for obtaining and observing all applicable safety regulations and rules.
The notices, in particular the test notices of this manual (e.g. on use, mounting, installation or
integration into the existing machine controller), must be observed.
The test must be carried out by specialised personnel or specially qualified and authorized
personnel and must be recorded and documented and retraced at any time by third parties.
The external voltage supply of the device must be capable of buffering brief mains voltage
failures of 20 ms as specified in EN 60204.
The modules of the MELSEC-WS safety controller conform to Class A, Group 1, in accordance
with EN 55011. Group 1 encompasses all the ISM devices in which intentionally generated
and/or used conductor-bound RF energy that is required for the inner function of the device
itself occurs.
The MELSEC-WS safety controller fulfils the requirements of Class A (industrial
applications) in accordance with the “Interference emission” basic specifications.
The MELSEC-WS safety controller is therefore only suitable for use in an industrial environment
and not for private use.
2
[Installation Precautions]
WARNING
Do not use the MELSEC-WS safety controller in flammable gas atmosphere or explosive gas
atmosphere. Doing so may result in a fire or explosion due to such as an arc caused by switching
the relays.
CAUTION
Use the MELSEC-WS safety controller in an environment that meets the general specifications in
this manual. Failure to do so may result in electric shock, fire, malfunction, or damage to or
deterioration of the product.
Latch the module onto the DIN mounting rail. Incorrect mounting may cause malfunction, failure or
drop of the module.
To ensure full electromagnetic compatibility (EMC), the DIN mounting rail has to be connected to
functional earth (FE).
Ensure that the earthling contact is positioned correctly. The earthling spring contact of the
module must contact the DIN mounting rail securely to allow electrical conductivity.
Shut off the external power supply for the system in all phases before mounting or removing the
module.
Failure to do so may result in damage to the product.
Do not directly touch any conductive part of the module.
Doing so can cause malfunction or failure of the module.
The MELSEC-WS safety controller is only suitable for mounting in a control cabinet with at least
IP 54 degree of protection.
Failure to meet the installation method may cause the module to fail or malfunction due to the
deposition of dust or the adhesion of water.
3
[Wiring Precautions]
WARNING
Shut off the external power supply for the system in all phases before wiring.
Failure to do so may result in electric shock or damage to the product.
The system could start up unexpectedly while you are connecting the devices.
CAUTION
Individually ground the GND wires of the MELSEC-WS safety controller with a ground resistance
of 100 Ω or less.
Failure to do so may result in electric shock or malfunction.
Check the rated voltage and terminal layout before wiring to the module, and connect the cables
correctly.
Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or
failure.
Tighten the terminal screw within the specified torque range.
Undertightening can cause short circuit, fire, or malfunction. Overtightening can damage the
screw and/or module, resulting in drop, short circuit, or malfunction.
Prevent foreign matter such as dust or wire chips from entering the module.
Such foreign matter can cause a fire, failure, or malfunction.
Mitsubishi MELSEC-WS safety controllers must be installed in control cabinets. Connect the main
power supply to the MELSEC-WS safety controller through a relay terminal block.
Wiring and replacement of an external power supply must be performed by maintenance
personnel who is familiar with protection against electric shock. (For wiring methods, refer to
Chapter 7.)
Place the cables in a duct or clamp them.
If not, dangling cable may swing or inadvertently be pulled, resulting in damage to the module or
cables or malfunction due to poor contact.
4
[Startup and Maintenance Precautions]
WARNING
Do not touch any terminal while power is on.
Doing so will cause electric shock.
Shut off the external power supply for the system in all phases before cleaning the module or
retightening the terminal screws. Failure to do so may result in electric shock.
Tighten the terminal screw within the specified torque range. Undertightening can cause short
circuit, fire, or malfunction.
Overtightening can damage the screw and/or module, resulting in drop, short circuit, or
malfunction.
Safety-oriented devices must be suitable for safety related signals.
A function interruption of safety outputs results in a loss of the safety functions so that the risk of
serious injury exists.
Do not connect any loads that exceed the rated values of the safety outputs.
Wire the MELSEC-WS safety controller so that 24 V DC signals cannot unintentionally contact
safety outputs.
Connect the GND wires of the power supply to earth so that the devices do not switch on when
the safety output line is applied to frame potential.
Use suitable components or devices that fulfill all the applicable regulations and standards.
Actuators at the outputs can be wired single-channeled. In order to maintain the respective Safety
Integrity Level the lines have to be routed in such a manner that cross circuits to other live signals
can be excluded, for example by routing them within protected areas such as in a control cabinet
or in separate sheathed cables.
5
CAUTION
Before performing online operations (Force mode) for the running MELSEC-WS safety controller
from the PC, read the relevant manuals carefully and ensure the safety.
The online operations must be performed by qualified personnel, following the operating
procedure determined at designing.
Fully understand the precautions described in the Safety Controller Setting and Monitoring Tool
Operating Manual before use.
Do not disassemble or modify the modules.
Doing so may cause failure, malfunction, injury, or a fire.
Mitsubishi does not warrant any products repaired or modified by persons other than Mitsubishi or
FA Center authorized by Mitsubishi.
Shut off the external power supply for the MELSEC-WS safety controller in all phases before
mounting or removing the module.
Failure to do so may cause the module to fail or malfunction.
After the first use of the product, do not mount/remove the module from/to the DIN mounting rail,
and the terminal block to/from the module more than 50 times (IEC 61131-2 compliant)
respectively.
Exceeding the limit of 50 times may cause malfunction.
Before handling the module, touch a grounded metal object to discharge the static electricity from
the human body.
Failure to do so may cause the module to fail or malfunction.
[Disposal Precautions]
CAUTION
When disposing of this product, treat it as industrial waste.
Disposal of the product should always occur in accordance with the applicable country-specific
waste-disposal regulations (e.g. European Waste Code 16 02 14).
6
CONDITIONS OF USE FOR THE PRODUCT
(1) Although MELCO has obtained the certification for Product's compliance to the international safety
standards IEC61508, ISO13849-1 from TUV Rheinland, this fact does not guarantee that Product will
be free from any malfunction or failure. The user of this Product shall comply with any and all
applicable safety standard, regulation or law and take appropriate safety measures for the system in
which the Product is installed or used and shall take the second or third safety measures other than
the Product. MELCO is not liable for damages that could have been prevented by compliance with
any applicable safety standard, regulation or law.
(2) MELCO prohibits the use of Products with or in any application involving, and MELCO shall not be
liable for a default, a liability for defect warranty, a quality assurance, negligence or other tort and a
product liability in these applications.
1) power plants,
2) trains, railway systems, airplanes, airline operations, other transportation systems,
3) hospitals, medical care, dialysis and life support facilities or equipment,
4) amusement equipments,
5) incineration and fuel devices,
6) handling of nuclear or hazardous materials or chemicals,
7) mining and drilling,
8) and other applications where the level of risk to human life, health or property are elevated.
7
REVISIONS
*The manual number is given on the bottom left of the back cover.
Print date *Manual numberRevision
September, 2009 SH(NA)-080856ENG-A First edition
March, 2010 SH(NA)-080856ENG-B A new module, CC-Link interface module, was added.
July, 2011 SH(NA)-080856ENG-C Description on Flexi Link system was added.
August, 2012 SH(NA)-080856ENG-D Setting and Monitoring Tool was upgraded.
August, 2014 SH(NA)-080856ENG-E A new module, WS0-CPU3 module, was added.
Description on Flexi Line system was added.
Setting and Monitoring Tool was upgraded.
August, 2016 SH(NA)-080856ENG-F Description on the corporate logo was changed.
November, 2018 SH(NA)-080856ENG-G Errors in writing are corrected.
Japanese manual version SH-080853-H
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses.
Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which
may occur as a result of using the contents noted in this manual.
WS0-MPL0 The abbreviation for the WS0-MPL000201 MELSEC-WS safety
controller memory plug
WS0-MPL1 The abbreviation for the WS0-MPL100201 MELSEC-WS safety
controller memory plug
WS0-CPU0 The abbreviation for the WS0-CPU000200 MELSEC-WS safety
controller CPU module
WS0-CPU1 The abbreviation for the WS0-CPU130202 MELSEC-WS safety
controller CPU module
WS0-CPU3 The abbreviation for the WS0-CPU 320202 MELSEC-WS safety
controller CPU module
WS0-XTIO The abbreviation for the WS0-XTIO84202 MELSEC-WS safety
controller safety I/O combined module
WS0-XTDI The abbreviation for the WS0-XTDI80202 MELSEC-WS safety
controller safety input module
WS0-4RO The abbreviation for the WS0-4RO4002 MELSEC-W S safety
controller safety relay output module
WS0-GETH The abbreviation for the WS0-GETH00200 MELSEC-WS safety
controller Ethernet interface module
WS0-GCC1 The abbreviation for the WS0-GCC100202 MELSEC-WS safety
controller CC-Link interface module
CPU module A generic term for the WS0-CPU0, WS0-CPU1 and WS0-CPU3
Safety I/O module A generic term for the WS0-XTIO and WS0-XTDI
Network module A generic term for the WS0-GETH and WS0-GCC1
Description
15
About this document
1 About this document
Please read this chapter carefully before working with this manual and the MELSECWS safety controller.
1.1 Function of this document
For the MELSEC-WS safety controller there are sets of manuals with clearly defined
applications as well as user’s manuals (hardware) for each module.
All MELSEC-WS modules and their functions are described in detail in “MELSEC-
WS series Safety Controller User's manual”. Use the Safety Controller User's
manual in particular for the planning of MELSEC-WS safety controllers.
The Safety Controller User's manual is designed to address the technical
personnel of the machine manufacturer or the machine operator in regards to
safe mounting, electrical installation, commissioning, operation and maintenance
of the MELSEC-WS safety controller.
The Safety Controller User's manual does not provide instructions for operating
machines on which the safety controller is, or will be, integrated. Information on
this is to be found in the operating instructions of the machine.
The software-based configuration and setting the parameters for the MELSEC-
WS safety controller are described in “MELSEC-WS series Safety Controller
Setting and Monitoring Tool Operating Manual". The operating manual also
contain a description of the diagnostic functions most important for operation and
detailed information on the identification and rectification of errors. Use the
operating manual in particular for the configuration, commissioning and operation
of MELSEC-WS safety controllers.
Chapter 1
MELSEC-WS network interface modules and their functions are described in
detail in the user's manuals for each network interface module. The network
interface module interface manuals are designed to address the technical
personnel of the machine manufacturer or the machine operator in regards to
safe mounting, electrical installation, commissioning as well as on maintenance of
the MELSEC-WS network interface modules. The network interface module
user's manuals also contain important information on the configuration of the
network interface module using the software Setting and Monitoring Tool, on the
exchange of data with networks as well as information on the status, the planning
and the related mapping.
The user’s manuals (hardware) are included with each MELSEC-WS module.
They provide basic technical specifications on the modules and contain simple
mounting instructions. Use the user’s manuals (hardware) when mounting the
MELSEC-WS safety controller.
These user's manuals are addressed to the planning engineers, designers and
operators of systems which are to be protected by a MELSEC-WS safety controller.
They also are addressed to people who integrate the MELSEC-WS safety controller
into a machine, commission it initially or who are in charge of servicing and
maintaining the unit.
These user's manuals do not provide instructions for operating the machine or
system in which a MELSEC-WS safety controller is integrated. Information of this
kind will be found in the operating instructions for the machine or system.
17
Note
About this document
Chapter 1
1.3 Function and structure of this manual
This manual instructs the technical personnel of the machine manufacturer or
machine operator in the software configuration, operation and diagnostics of a
MELSEC-WS safety controller using the Setting and Monitoring Tool. It only applies
in combination with the Safety Controller User’s Manual.
Planning and using SICK protective devices also require specific technical skills
which are not detailed in this documentation.
Chapter 2 contains fundamental safety instructions. These instructions must be read.
When operating the MELSEC-WS modular safety controller, the national, local and
statutory rules and regulations must be observed.
For the acquisition of Setting and Monitoring Tool, please contact your local
Mitsubishi representative.
The SICK EFI-compatible devices and SICK configuration and diagnostics software
CDS are the products of SICK.
For details of the SICK products, please contact your local SICK representative (see
Section 15.4).
www.sick.com
1.3.1 Recommendations for familiarising yourself with Setting and
Monitoring Tool
We recommend the following procedure for users who want to familiarize
themselves with Setting and Monitoring Tool for the first time:
Read Chapter 5 to familiarize yourself with the graphical user interface and do the
exercises for the configuration of example applications.
1.3.2 Recommendations for experienced users
We recommend the following procedure for experienced users who have already
worked with Setting and Monitoring Tool:
Familiarize yourself with the most recent version of the software by reading
Section 1.4.
The table of contents lists all functions provided by the Setting and Monitoring
Tool. Use the table of contents to obtain information about the basic functions.
1.4 Scope and version
These user's manuals are original manuals.
These user's manuals apply for the Setting and Monitoring Tool software version
V1.2.0 or higher, CPU0 and CPU1 with firmware version V1.11 or higher, and CPU3
with firmware version V3.02 or higher.
This version of the user's manuals describes version V1.7.0 of the Setting and
Monitoring Tool software.
Recommendations are designed to give you some assistance in your decisionmaking process with respect to a certain function or a technical measure.
Note provides special information on a device or a software function.
Instructions for taking action are shown by an arrow. Read carefully and follow the
instructions for action.
ATTENTION!
An “ATTENTION” indicates concrete or potential dangers. It is intended to protect
you from harm and help avoid damage to devices and systems.
Read warnings carefully and follow them!
Otherwise the safety function may be impaired and a dangerous state may occur.
Menus and
commands
Key
The names of software menus, submenus, options and commands, selection boxes
and windows are highlighted in bold. Example: Click Edit in the File menu.
The term “dangerous state”
The dangerous state (standard term) of the machine is always shown in the
drawings and diagrams of this document as the movement of a machine part. In
practical operation, there may be a number of different dangerous states:
machine movements
electrical conductors
visible or invisible radiation
a combination of several risks and hazards
Keys are shown in uppercase.
Keys to be pressed sequentially are hyphenated with “-”.
Example: “CTRL+ALT+DEL” indicates to press these keys simultaneously. “F12-2”
indicates to press these keys sequentially. The key names are based on the
standard keyboard. Some users may use a keyboard with a different language
layout such as German.
19
On safety
2 On safety
This chapter deals with your own safety and the safety of the equipment operators.
Please read this chapter carefully before working with a MELSEC-WS safety
2.1 Qualified safety personnel
The MELSEC-WS safety controller must be installed, configured, commissioned and
serviced only by qualified safety personnel. Qualified safety personnel are defined
as persons who
have undergone the appropriate technical training
and
have been instructed by the responsible machine operator in the operation of the
and
are sufficiently familiar with the applicable official health and work safety regulations,
and
have access to the MELSEC-WS manuals and have and read and familiarised
and
have access to the operating instructions for the protective devices (e.g. C4000)
Chapter 2
controller.
machine and the current valid safety guidelines
directives and generally recognized engineering practice (e.g. DIN standards, VDE
stipulations, engineering regulations from other EC member states) that they can
assess the work safety aspects of the power-driven equipment
themselves with them
connected to the safety controller and have read and familiarised themselves with
them.
ATTENTION
2.2 Correct use
The Setting and Monitoring Tool is used to configure a MELSEC-WS safety
controller consisting of modules of the safety controller.
The MELSEC-WS safety controller may only be used by qualified safety personnel
and only at the machine at which it was mounted and initially commissioned by
qualified safety personnel in accordance with the MELSEC-WS manuals.
Mitsubishi Electric Corporation accepts no claims for liability if the software or the
devices are used in any other way or if modifications are made to the software or the
devices - even in the context of mounting and installation.
Observe the safety instructions and protective measures of the Safety Controller
User’s Manual and this manual!
When implementing a safety-relevant functional logic, ensure that the regulations
of the national and international rules and standards are observed, in particular
the controlling strategies and the measures for risk minimisation that are
mandatory for your application.
20
Chapter 2
Note
On safety
2.3 General protective notes and protective
measures
Observe the protective notes and measures!
Please observe the following items in order to ensure proper use of the MELSECWS safety controller.
When mounting, installing and using the MELSEC-WS safety controller, observe
the standards and directives applicable in your country.
The national and international rules and regulations apply to the installation and use
as well as commissioning and periodic technical inspection of the MELSEC-WS
safety controller, in particular:
– Machinery Directive 2006/42/EC,
– EMC Directive 2004/108/EC,
– Provision and Use of Work Equipment Directive 2009/104/EC and the
supplementary Directive 35/63/EC,
– Low-Voltage Directive 2006/95/EC,
– Work safety regulations and safety rules.
Manufacturers and owners of the machine on which a MELSEC-WS safety
controller is used are responsible for obtaining and observing all applicable safety
regulations and rules.
21
Version, compatibility and features
3 Version, compatibility and features
For the MELSEC-WS series several firmware versions and function packages exist
that allow different functions. This chapter gives an overview which firmware version,
which function package and/or which version of the Setting and Monitoring Tool is
required to use a certain function or device.
Table 2:
Required firmware and
software versions
Logic offline simulation –*1 – V1.2.0
Logic import/export – – V1.3.0
Online edit – – V1.3.0
Automatic wiring diagrams – – V1.3.0
Central tag name editor – – V1.3.0
Flexi Link (only with WS0CPU1/WS0-CPU3)
Flexi Line (only with WS0-CPU3)
Function block documentation
within the Setting and Monitoring
Tool
Input/output relation matrix – – V1.3.0
Invertable inputs for the AND,
OR, RS Flip-Flop and Routing
N:N function blocks
Ramp down detection function
block
Adjustable on-delay timer and
adjustable off-delay timer
function blocks
Fast Shut Off with Bypass
function block (only with WS0XTI0)
Deactivation of test pulses on
Q1–Q4 on the WS0-XTIO
possible
Verification without identical
hardware possible
Status input data and Status
output data in logic
Data recorder
Extended cross-circuit detection
time for switching loads with
high capacitance
Adjustable filter time for ON-OFF
filter and OFF-ON filter on the
inputs I1 to I8 of the WS0XTIO/WS0-XTDI
Feature WS0-CPU
V2.01
(Revision 2.xx)
V3.02
(Revision 3.xx)
– – V1.3.0
V2.01
(Revision 2.xx)
V1.11
(Revision 1.xx)
V2.01
(Revision 2.xx)
V2.01
(Revision 2.xx)
–
V2.01
(Revision 2.xx)
V2.01
(Revision 2.xx)
V2.01
(Revision 2.xx)
–
–
Minimum required version
Chapter 3
WS0-XTIO/
WS0-XTDI
– V1.3.0
– V1.7.0
– V1.3.0
– V1.3.0
– V1.3.0
V2.00
(Revision 2.xx)
V2.00
(Revision 2.xx)
– V1.3.0
V2.00
(Revision 2.xx)
– V1.7.0
V3.10
(Revision 3.xx)
V3.10
(Revision 3.xx)
Setting and
Monitoring Tool
V1.7.0
V1.3.0
V1.3.0
V1.7.0
V1.7.0
22
Chapter 3
Version, compatibility and features
Note
Device WS0-CPU
Ethernet interface module V1.11
(Revision 1.xx)
CC-Link interface module V1.11
(Revision 1.xx)
ROHS conformity WS0-XTIO – V1.01*2 –
*1 “–” means “any” or “not applicable”.
*2 All other modules from product launch onwards.
WS0-XTIO/
WS0-XTDI
– V1.2.0
– V1.2.1
Setting and
Monitoring Tool
You can find the firmware version on the type label of the MELSEC-WS modules in
the field Firmware version.
In order to use modules with a newer firmware version, a new Setting and
Monitoring Tool version is required. For CPU0/1 ≥ V2.01 and XTIO/XTDI ≥ V2.00
Setting and Monitoring Tool V1.3.0 or higher is required. This has to be considered
when devices are to be replaced in existing systems.
You will find the firmware version of the MELSEC-WS modules in the hardware
configuration view of the Setting and Monitoring Tool when the system is online or
in the report if the system has been online before.
The version of the Setting and Monitoring Tool can be found in the Extras menu
under About.
For the acquisition of the newest version of the Setting and Monitoring Tool, please
contact your local Mitsubishi representative.
The function package (Revision 1.xx or Revision 2.xx) must be selected in the
Setting and Monitoring Tool hardware configuration. Function package Revision
2.xx is available with Setting and Monitoring Tool 1.3.0 and higher.
In order to use function package Revision 2.xx, the respective module must have at
least firmware version V2.00.0. Otherwise you will receive an error message when
you try to upload a configuration using Revision 2.xx to a module with a lower
firmware version.
Newer modules are downward compatible so that any module can be replaced by a
module with a higher firmware version.
The same firmware version and function package revision as those of the module
used must be set to the new project after a project stored in the memory plug is
modified.
You will find the device’s date of manufacture at the bottom of the type label in the
format yywwnnnn (yy = year, ww = calendar week, nnnn = continuos serial number
in the calendar week).
23
Installation and removal
4 Installation and removal
4.1 System requirements
Recommended system configuration:
Windows XP (32 Bit/64 Bit), Windows Vista (32 Bit/64 Bit), or Windows 7 (32 Bit/64
Bit)
Microsoft .NET Framework 3.5
1 GHz processor
1 GB RAM
1024 × 768 pixel screen resolution
300 MB free hard disk memory
Chapter 4
Note
Note
Setting and Monitoring Tool is a .NET Framework application. It requires .NET
Framework Version 3.5 or higher.
Information on the current .NET Framework versions, supported operating systems,
and Regional and Language Options settings is available on the Internet at
www.microsoft.com
Microsoft .NET Framework Version 3.5 or higher and any other components that
may be needed can also be downloaded from www.microsoft.com/downloads.
Use a standard user account or higher in Windows Vista or Windows 7.
To display text of Setting and Monitoring Tool in Chinese, use Chinese version of
Windows operating systems.
To display text of Setting and Monitoring Tool in Japanese or Chinese in Windows
XP (English version), add the language in the Regional and Language Options
dialog box. (The dialog box can be accessed from Control Panel.)
4.2 Installation and Update
For the acquisition of Setting and Monitoring Tool (including information for
installation), please contact your local Mitsubishi representative.
Start the installation by running the setup.exe file and then follow the further
instruction.
New software versions may contain new functions and support new MELSEC-WS
modules. The version of the Setting and Monitoring Tool can be found in the Extras
menu under About.
Remove the old software version before installing a new one. The working directory
in which the project data are stored is not overwritten during the new installation and
is retained. When an RS232-USB converter (WS0-UC-232A) is used, install a driver
from the CD ROM provided with the converter.
When an RS232-USB configuration cable (WS0-C20M8U) is used, please contact
your local Mitsubishi representative for a driver of the cable.
24
Chapter 4
Table 3:
Errors and error elimination
Installation and removal
4.3 Removal
The Setting and Monitoring Tool can be removed as follows:
In the Windows Start menu, start Uninstall Setting and Monitoring Tool in the
Setting and Monitoring Tool program folder.
4.4 Troubleshooting
Error/Error message Cause Rectification
When Setting and Monitoring
Tool is started, the following
or a similar error message is
displayed: “DLL not found –
the Dynamic Link Library
mscoree.dll was not found in
the specified path.
Specify the registration key
HKLM\Software\Microsoft\ N
ETFramework\InstallRoot so
that it refers to the
installation location of
the .NET Framework.”
Microsoft .NET Framework is
not installed on the PC.
Install a suitable version of
Microsoft .NET Framework.
Ask your system
administrator if
appropriate. .NET
Framework is available for
downloading on the internet
pages of Microsoft.
Note:
Install .NET Framework 3.5
25
The graphical user interface
5 The graphical user interface
Chapter 5
Note
Figure 1:
Start view with selection of
the action
This chapter familiarizes you with the basic elements of the graphical user interface as
an introduction. This chapter does not give any information on the configuration of
MELSEC-WS modules nor any instructions for logic programming. This chapter is only
intended to explain the fundamental functioning of the Setting and Monitoring Tool on
the basis of a small section of the functions. Experienced users of Setting and
Monitoring Tool can skip this chapter.
5.1 Start view
After the Setting and Monitoring Tool has been started, the start view is displayed. The
user can specify here with which of the following actions he wants to start:
Open existing project file
Connect to physical device
Create new project
Create new Flexi Link project
Edit com. Interface settings
5.2 Setting the desired language
Click the flag icon in the menu bar at the far right and select the desired language
version.
26
Chapter 5
Figure 2:
The view can be selected
below the menu bar
The graphical user interface
5.3 Standard views
The Setting and Monitoring Tool has the following views that can be accessed via
buttons below the menu bar.
Note
The structure of a MELSEC-WS safety controller consisting of various hardware
modules as well as the configuration of the inputs and outputs and the connected
elements are specified in the Hardware configuration view.
The function logic can be configured by means of logic function blocks and
application-specific function blocks in the Logic editor view. This view is not
available unless a CPU module has been selected beforehand in the hardware
configuration.
If the project contains at least one network module or if RS-232 communication is
enabled, the Network module [13] view is available. Here you can configure the
network module and the data that are transferred to and from the network.
Do not save the project data while Setting and Monitoring Tool is connected to the
MELSEC-WS safety controller.
Before saving the project data, disconnect the PC from the MELSEC-WS safety
controller.
Complete information on the currently loaded project and all settings including the
logic programming and wiring diagrams is available in the Report view.
Furthermore, additional information on the project can be entered here. All
information can be saved in standard file formats and printed out. The scope of the
report can be compiled individually depending on the selection.
27
The stored error messages are displayed as a history of a connected MELSEC-WS
safety controller in the Diagnostics view.
Input and output signals from a MELSEC-WS safety controller can be recorded and
displayed inthe Data recorder view.