Dimensions W × H × Dmm800 × 550 × 285840 × 850 × 330
Weightkg30333654
NOTE: Test conditions are based on ISO 5151.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor Dry-bulb temperature 20°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Refrigerant piping length (one way): 5 m
1 Measured under rated operating frequency.
1 (Total)
Dehumidifi cationCooling/h0.20.91.41.8
Air fl ow 1
Sound level 1
Special remarks
Fan speed
Fan speed regulator32
Refrigerant fi lling capacity (R410A)kg0.801.151.55
The standard specifications apply only to the operation of the air conditioner under normal conditions. Since operating condi-
tions vary according to the areas where these units are installed, the following information has been provided to clarify the
operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198 ~ 264 V, 50 Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature:°C [WB]
(2) Indoor outlet air wet-bulb temperature:°C [WB]
(3) Outdoor intake air dry-bulb temperature:°C [DB]
(4) Total input:W
(5) Indoor intake air dry-bulb temperature:°C [DB]
(7) Total input:W
Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the
indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
How to measure the indoor air wet-bulb / dry-bulb temperature difference
1. Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
}
}
Cooling
Heating(6) Outdoor intake air wet-bulb temperature:°C [WB]
INDOOR UNITOUTDOOR UNIT
Wet and dry-bulb
thermometers
FRONT VIEW
8-1. CAPACITY AND INPUT CURVES
6.6
8.4
6.1
7.7
5.6
7.1
5.1
6.5
4.6
4.2
3.7
5.9
5.3
4.7
difference (°C)
Indoor air Wet-bulb temperature
10.4
9.5
8.7
8.0
7.2
6.5
5.7
10.2
9.4
8.6
7.9
7.1
6.4
5.7
1.5
1.4
1.3
1.2
1.1
1.0
Capacity correction factors
0.9
-10-5 0 5 1015202530354045
Cooling capacity (
Outdoor intake air Dry-bulb temperature(°C)
Wet and dry-bulb
thermometers
BACK VIEW
at Rated frequency)
Indoor intake air Wet-bulb
temperature( )
26
24
22
20
18
MUZ-GE25VA
MUZ-GE25VAH
MUZ-GE35VA
MUZ-GE35VAH
MUZ-GE50VA
MUZ-GE42VA
MUZ-GE50VAH
MUZ-GE42VAH
17