1 RoHS PARTS LIST
MS-GF20VA MS-GF25VA MS-GF35VA
1-1. INDOOR UNIT STRUCTURAL PARTS
1
8
2
3
4
5
1-2. ACCESSORY AND REMOTE CONTROLLER
9
10
7
6
2
RoHS PARTS LIST
OBB621A
1-1. INDOOR UNIT STRUCTURAL PARTS
E1
Q'ty/unit
MS-GF
25VA -
E1
MS-GF
35VA -
E1
Remarks
2 PCS/SET 2 PCS/SET
KM12A
No.
1 G E12 F89 234 BOX ASSEMBLY 1 1 1 2 G E12 H07 000 PANEL ASSEMBLY 1 1 1 Including No. 3,4,5 3 G E12 408 142 CATCH 2 2 2 4 G E12 913 067 SCREW CAP 2 2 2 5 G E12 D68 010 FRONT PANEL 1 1 1 6 G E12 F63 100 NANO PLATINUM FILTER 2 2 2 1 PC/SET 7 G E12 D68 975 CORNER BOX (RIGHT) 1 1 1 8 G E12 D68 970 INSTALLATION PLATE 1 1 1
Part No. Part name
RoHS
Symbol
in Wiring
Diagram
MS-GF
20VA -
1-2. ACCESSORY AND REMOTE CONTROLLER
9 G E12 H07 426 REMOTE CONTROLLER 1 1 1
10 G E12 527 083
REMOTE CONTROLLER HOLDER
111
3
RoHS PARTS LIST
OBB621A
MS-GF20VA MS-GF25VA MS-GF35VA
1-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
1
18
16 13
MOTOR BED
15
ELECTRICAL BOX
14 12
2
3
4
DRAIN CAP
17
CABLE GUIDE
TERMINAL BLOCK
11
ELECTRICAL COVER
5
6
7
8
9
10
4
RoHS PARTS LIST
OBB621A
1-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
E1
Q'ty/unit
MS-GF
25VA -
E1
MS-GF
35VA -
E1
Remarks
No.
1 G E12 751 509 BEARING MOUNT 1 1 1 2 G E12 001 504 SLEEVE BEARING 1 1 1 3 G E12 897 702 DRAIN HOSE 1 1 1 4 G E12 H07 235 NOZZLE ASSEMBLY 1 1 1 5 G E12 F87 040 VANE (UPPER) 1 1 1 6 G E12 F87 041 VANE (LOWER) 1 1 1 7 G E12 A89 303 VANE MOTOR MV 1 1 1 UP & DOWN
8 G E12 D68 308
9
10 G E12 F87 095
11 G E12 H07 440 12 G E12 F89 307 INDOOR COIL THERMISTOR RT12 1 1 1 13 G E12 B75 385 VARISTOR NR11 1 1 1 14 G E12 A49 382 FUSE F11 1 1 1 T3.15AL250V 15 G E12 F87 784 V.A. CLAMP 1 1 1 16 G E12 H07 300 17 G E12 D68 333 MOTOR BAND 1 1 1 18 G E12 A89 302 LINE FLOW FAN 1 1 1
Part No. Part name
RoHS
ROOM TEMPERATURE
THERMISTOR G E12 H07 452 G E12 H08 452 1
INDOOR ELECTRONIC
CONTROL P.C. BOARD
INDOOR ELECTRONIC
CONTROL P.C. BOARD HOLDER
POWER P.C. BOARD
INDOOR FAN MOTOR
1
2
Symbol
in Wiring
Diagram
RT11 1 1 1
MF 1 1 1 RC4V18-□□
MS-GF
20VA -
11
111
111
1 Including TERMINAL BLOCK with TERMINAL P.C. BOARD 2 Including FAN MOTOR RUBBER MOUNT (2 PCS/SET)
5
RoHS PARTS LIST
OBB621A
MS-GF20VA MS-GF25VA MS-GF35VA
1-4. INDOOR UNIT HEAT EXCHANGER
1
2
3
E1
Q'ty/unit
MS-GF
25VA -
E1
MS-GF
35VA -
E1
No.
1G
2 G E12 815 666 UNION (GAS) 1 1 1 ø9.52
3G
Part No. Part name
RoHS
E12 H07 620 E12 H08 620 1
E12 C32 667 E12 C68 667 1 ø6.35
INDOOR HEAT EXCHANGER
UNION (LIQUID)
Symbol
in Wiring
Diagram
MS-GF
20VA -
11
1 1 ø6.35
Remarks
6
RoHS PARTS LIST
OBB621A
MS-GF50VA MS-GF60VA MS-GF80VA
1-1. INDOOR UNIT STRUCTURAL PARTS
1
9
2
3
8
7
4
5
No.
1 G E12 H09 234 BOX ASSEMBLY 1 1 1
2 G E12 H09 000 PANEL ASSEMBLY 1 1 1 Including No. 3,4,5
3 G E12 408 142 CATCH 4 4 4 4 G E12 F28 067 SCREW CAP 3 3 3 5 G E12 F28 010 FRONT PANEL 1 1 1 6 G E12 F28 100 NANO PLATINUM FILTER 2 2 2 1 PC/SET 7 G E12 F28 975 CORNER BOX (RIGHT) 1 1 1 8 G E12 F28 976 CORNER BOX (LEFT) 1 1 1 9 G E12 F28 970 INSTALLATION PLATE 1 1 1
Part No. Part name
RoHS
Symbol
in Wiring
Diagram
50VA-
E1
6
Q'ty/unit
MS-GF
E1
60VA-
80VA-
Remarks
E1
4 PCS/SET 3 PCS/SET
1-2. ACCESSORY AND REMOTE CONTROLLER
No.
10 G E12 H09 426 REMOTE CONTROLLER 1 1 1
11 G E12 527 083
10
Part No. Part name
RoHS
REMOTE CONTROLLER HOLDER
11
Symbol
in Wiring
Diagram
Q'ty/unit
MS-GF
E1
50VA-
111
7
60VA-
E1
80VA-
Remarks
E1
KM12B
RoHS PARTS LIST
OBB621A
MS-GF50VA MS-GF60VA MS-GF80VA 1-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
1
20
2
18 14
MOTOR BED
17
ELECTRICAL BOX
3
16 15
4
DRAIN CAP
19
TERMINAL BLOCK
ELECTRICAL COVER
13
5
6
E1
9
Q'ty/unit
MS-GF
60VA-
E1
10
11
80VA-
12
Remarks
E1
□□
7
No.
1 G E12 751 509 BEARING MOUNT 1 1 1 2 G E12 001 504 SLEEVE BEARING 1 1 1 3 G E12 408 702 DRAIN HOSE 1 1 1 4 G E12 H09 235 NOZZLE ASSEMBLY 1 1 1 5 G E12 F76 040 VANE (UPPER) 1 1 1 6 G E12 F76 041 VANE (LOWER) 1 1 1 7 G E12 C33 303 VANE MOTOR (HORIZONTAL) MV1 1 1 1 UP & DOWN 8 G E12 C32 303 VANE MOTOR (VERTICAL) MV2 2 2 2 RIGHT & LEFT 9 G E12 F28 541 WATER CUT 1 1 1
10 G E12 C32 308
11 G E12 F28 468
12 G E12 F28 095
13
14 G E12 F34 307 INDOOR COIL THERMISTOR RT12 1 1 1 15 G E12 B75 385 VARISTOR NR11 1 1 1 16 G E12 A49 382 FUSE F11 1 1 1 T3.15AL250V 17 G E12 F28 784 V.A. CLAMP 1 1 1 18 G E12 F28 300 INDOOR FAN MOTOR 2 MF 1 1 1 RC0J56­19 G E12 F28 333 MOTOR BAND 1 1 1 20 G E12 F28 302 LINE FLOW FAN 1 1 1
1 Including TERMINAL BLOCK with TERMINAL P.C. BOARD 2 Including FAN MOTOR RUBBER MOUNT (2 PCS/SET)
Part No. Part name
RoHS
ROOM TEMPERATURE THERMISTOR
POWER MONITOR RECEIVER SW P.C. BOARD
POWER MONITOR RECEIVER HOLDER
G E12 H09 452 G E12 H10 452 1 G E12 H11 452 1
ELECTRONIC CONTROL P.C. BOARD 1
Symbol in Wiring Diagram
RT11 1 1 1
8
50VA-
111
111
1
8
RoHS PARTS LIST
OBB621A
MS-GF50VA MS-GF60VA MS-GF80VA 1-4. INDOOR UNIT HEAT EXCHANGER
1
2
3
No.
1
2
3
Part No. Part name
RoHS
G E12 H09 620 G E12 H10 620 1 G E12 H11 620 1 G E12 179 667 G E12 527 666 1 1 G E12 151 667 G E12 151 666 1
INDOOR HEAT EXCHANGER
UNION (GAS)
UNION (LIQUID)
Symbol
in Wiring
Diagram
E1
50VA-
1
1
11
Q'ty/unit
MS-GF
E1
60VA-
80VA-
Remarks
E1
ø12.7 ø15.88 ø6.35 ø9.52
9
2
2-1.
OPTIONAL PARTS
AIR CLEANING FILTER (ELECTROSTATIC ANTI-ALLERGY ENZYME FILTER)
Every 3 months:
● Remove dirt by a vacuum cleaner.
When dirt cannot be removed by vacuum cleaning:
● Soak the filter and its frame in lukewarm water before rinsing it.
● After washing, dry it well in shade. Install all tabs of the air filter.
Every year:
● Replace it with a new air cleaning filter for best performance.
NOTE 1: Clean the filters regularly for best performance and to reduce power consumption. NOTE 2: Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold.
It is therefore recommended to clean air filters every 2 weeks.
Pull to remove from the air flter
Model Part No.
MS-GF20VA MS-GF25VA MS-GF35VA
MAC-2320FT
Model Part No.
MS-GF50VA MS-GF60VA MS-GF80VA
MAC-2310FT
Air cleaning filter (Electrostatic anti-allergy enzyme filter)
Air cleaning filter (Electrostatic anti-allergy enzyme filter)
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
© Copyright 2012 MITSUBISHI ELECTRIC CORPORATION
Distributed in Feb. 2013. No. OBB621 REVISED EDITION-A Distributed in Oct. 2012. No. OBB621 Made in Japan
New publication, effective Feb. 2013 Specifications are subject to change without notice.
Loading...