Installation plan
PFD 101
PFD 101 i
PFD 101 U
en-GB
M.-Nr. 11 673 200
Contents
Installation notes ............................................................................................................. 3
Installation requirements ............................................................................................... 3
Environmental requirements.......................................................................................... 3
Electrical connection ..................................................................................................... 3
Water connection .......................................................................................................... 4
Appliance dimensions and installation dimensions..................................................... 6
Freestanding appliance ..................................................................................................... 6
Built-in appliance/built-under appliance ........................................................................... 6
Front panel dimensions PFD101i .................................................................................... 6
Connections..................................................................................................................... 7
Connections on the back of the appliance ....................................................................... 7
On-site connections .......................................................................................................... 7
External dispensing ........................................................................................................... 8
Technical data.................................................................................................................. 9
Dimensions and weights ................................................................................................... 9
Emission levels.................................................................................................................. 9
Electrical connection ......................................................................................................... 10
Water inlet ......................................................................................................................... 10
Drain .................................................................................................................................. 10
Operating conditions......................................................................................................... 11
Storage and transportation conditions.............................................................................. 11
2
Installation notes
Installation notes
For safe installation and commissioning of the dishwasher please
read the installation plan, the service documentation, the installation sheet and the operating instructions.
This installation plan includes the dimensions of the appliance, the
technical data and the requirements to be met on site for the installation of the dishwasher.
Installation requirements
Environmental requirements
Vapour barrier film
for built-in appliances
Electrical connection
Plug connection
Hard-wired
This dishwasher must only be installed and commissioned by the
Miele Customer Service Department, a Miele authorised dealer or a
suitably qualified specialist.
Installation should only be performed in accordance with valid regulations, relevant standards and health and safety codes.
Condensate can build up in the area surrounding the dishwasher. Any
furniture and fittings in the room must therefore be suitable for purpose.
The vapour barrier film supplied protects the worktop from damage
caused by steam when the door is opened. Attach the vapour barrier
film above the door, underneath the worktop.
All work on the electrical connection must be carried out by the Miele
Customer Service Department, an authorised Miele dealer or a qualified electrician.
The dishwasher should be connected to the electricity supply via a
suitably rated plug and socket.
If the dishwasher is hard-wired to the power supply, a power switch
capable of disconnecting the dishwasher at all poles must be installed on site. This power switch must have a contact gap of at least
3mm.
Residual current
device (RCD)
Equipotential
bonding
The socket and the power switch must be accessible after the appliance has been installed. An electrical safety test can then easily be
carried out, e.g., after any service or maintenance work.
The connection cable must be protected from the risk of thermal
damage.
For increased safety, it is recommended to protect the dishwasher
with a residual current device (RCD) with a trip current of 30mA.
There is a screw connection point for equipotential bonding at the
back of the dishwasher.
Equipotential bonding should be carried out if possible on site.
3
Installation notes
Water connection
Water inlet
The dishwasher must only be connected to fully vented pipework.
A brief increase in the water pressure can damage components of
the dishwasher.
The quality of the incoming water must correspond to the drinking
water specification of the country in which the dishwasher is being
operated.
The dishwasher must be connected to the water supply in strict accordance with current local and national water authority regulations. It
can be connected to cold or hot water supplies. Connecting the dishwasher to a hot water supply will reduce programme running times.
For short programme running times, dynamic water pressure of at
least 200kPa is also required.
UK installation requirements:
The double check valve supplied with this product must be installed
between the stopcock and the water inlet hose.
Screw the double check valve onto the stopcock. Then screw the
water inlet hose with the water protection system onto the thread of
the double check valve.
If a stopcock is not available, only a qualified installer may connect
the dishwasher to the mains water supply.
The stopcock should remain accessible once the dishwasher has
been installed so that the water supply can be shut off whenever the
appliance is not in use.
4