Linear AP-4 Owner's Manual

TM
®
AP-4
Wireless Access Control Receiver
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
SAFETY WARNING
MOVING DOOR OR GATE CAN CAUSE SERIOUS INJURY OR DEATH
THIS UNIT CAUSES OPERATION OF A DOOR OR GATE MOTOR.
STAY CLEAR OF MOVING PARTS IF THIS UNIT IS MOUNTED
INSIDE THE DOOR OR GATE OPERATOR!
STAY CLEAR OF THE DOOR/GATE OR DISCONNECT THE ACCESS
RELAY WIRES WHEN PROGRAMMING OR SERVICING THIS UNIT!
ELECTRICAL CONNECTIONS RECEIVER INSTALLATION ANTENNA INSTALLATION
NOTE: THE EARTH GROUND CONNECTION IS OPTIONAL, BUT RECOMMENDED
OPEN REQUEST PUSHBUTTON
OPTIONAL CONNECTION PROVIDES A HARDWIRED METHOD TO ACTIVATE THE ACCESS DEVICE
PUSHBUTTON
OR RADIO
TERMINALS
ACCESS DEVICE
OBSTACLE
TERMINALS
DC -
12-24 VOLTS AC/DC
DC +
AP-4
TERMINALS
EARTH GND
OPEN REQUEST
ACCESS
RELAY
OBSTACLE
RELAY
OBSTACLE RELAY TERMINALS
CONNECT TO THE NORMALLY OPEN OR NORMALLY CLOSED RELAY TERMINALS AS REQUIRED BY THE ACCESS DEVICE
N.C.
COM
K1
N.O.
N.C
COM
K2
N.O. AC2 AC1
ACCESS RELAY AND
EARTH GROUND
GROUND STAKE, COLD WATER PIPE OR UNIFIED EARTH GROUND
POWER INPUT
LOW VOLTAGE PLUG-IN TRANSFORMER OR POWER FROM ACCESS DEVICE
INTRODUCTION
The AP-4 is designed for a broad range of access control applications. Its wireless design and small size make it easily adaptable for a variety of access control requirements. Typically, the AP-4 is used to control a door strike, barrier gate, automatic gate or automatic door operator. The AP-4 contains a high-gain UHF receiver which uses an external antenna to pick up signals from up to 250 feet away. Up to 480 Linear MegaCode® transmitters and one Model MGT safety edge transmitter can be programmed into the AP-4’s memory. The AP-4 will retain its memory, even without power. Two dry contact relay outputs are provided. One relay is the ACCESS RELAY (K1), which triggers for two seconds each time a programmed transmitter is activated. This relay output connects to the pushbutton or radio input of the access device. The second relay is the OBSTACLE RELAY (K2), which triggers for two seconds when an obstacle signal is sent from a Model MGT safety edge transmitter. This relay output connects to the obstacle input of the access device. An OPEN REQUEST input terminal is supplied for hardwired activation of the access device with an external pushbutton or keyswitch. The AP-4 can be powered from 12-24 Volts AC or DC. The Form C relay outputs can switch up to 1 Amp each. An EARTH GROUND terminal is provided as an optional connection for maximum lightning and static protection. Three utility functions can be displayed by pressing the pound (#) key then the digits 1-3. The utility functions display the status of the obstacle transmitter (#1), the total number of transmitters programmed (#2), and the total number of transmitter ID blocks programmed (#3).
AP-4 FEATURES
DISPLAYS LAST 3 DIGITS OF THE TRANSMITTERS ID NUMBER DURING OPERATION AND PROGRAMMING. ALSO DISPLAYS MGT SUPERVISION STATUS AND SYSTEM UTILITY INFORMATION.
PROGRAM BUTTON
PUSH FOR 3 SECONDS TO ENTER PROGRAM MODE. PRESS MOMENTARILY TO EXIT PROGRAM MODE.
CANCEL BUTTON
CLEARS THE KEYPAD AND DISPLAY IN CASE OF AN INCORRECT PROGRAMMING
ALSO CLEARS ANY SUPERVISORY
ENTRY.
TROUBLE CODES FROM AN MGT OBSTACLE TRANSMITTER.
OPEN BUTTON
PUSH TO ACTIVATE THE ACCESS RELAY.
MOUNT THE RECEIVER USING THE TWO SCREWS PROVIDED
CLOSE THE CASE AND SECURE IT USING THE TWO SCREWS PROVIDED
DIGITAL DISPLAY
DISPLAY BUTTON
SHIFTS THE DISPLAY TO SHOW THE LEFT THREE DIGITS OF THE 6-DIGIT TRANSMITTER ID NUMBER DURING OPERATION OR PROGRAMMING.
STAR ( ) KEY
DISPLAYS THE ID NUMBER OF THE LAST TRANSMITTER ACTIVATED. (USE THE DISPLAY BUTTON TO VIEW THE LEFT THREE DIGITS OF THE ID NUMBER.)
1. MOUNT RECEIVER IN AN AREA PROTECTED FROM THE ELEMENTS
2. IF USING THE LOCAL WHIP ANTENNA, THE HIGHER THE RECEIVER IS MOUNTED, THE BETTER THE RADIO RANGE WILL BE
3. OPTIONALLY, MOUNT THE RECEIVER IN A METAL CABINET AND USE AN EXTERNAL ANTENNA
NUMERIC KEYPAD
FOR ENTERING TRANSMITTER ID NUMBERS, PROGRAMMING, AND UTILITY FUNCTION NUMBERS.
NOTES:
The AP-4 can fully supervise the MGT safety edge transmitter. The system monitors the MGT transmitter for hourly status reports, tamper signals, and low battery signals. A beep will sound every 5 seconds if a fault occurs and the trouble source can be displayed by pressing pound-one (#1). A transmitter must be activated twice to trigger the ACCESS RELAY if a supervisory trouble condition exists on the MGT transmitter (unless the MGT has been suspended). To clear the supervisory trouble after servicing, press the CANCEL button.
MOUNTING SCREWS
CASE
WHIP ANTENNA
3-FOOT ANTENNA
MODEL AP-4 RECEIVER
ANTENNA CONNECTOR
FOR DIRECT CONNECTION TO THE LOCAL WHIP ANTENNA OR, WITH A COAX CABLE, TO A REMOTE ANTENNA.
POUND (#) KEY
PRESS # THEN 1-3 FOR UTILITY FUNCTIONS: #-1 DISPLAYS THE MGT SUPERVISORY STATUS. #-2 DISPLAYS NUMBER OF PROGRAMMED TRANSMITTERS. #-3 DISPLAYS NUMBER OF PROGRAMMED TRANSMITTER ID BLOCKS.
LOCAL WHIP ANTENNA
ATTACH THE LOCAL WHIP ANTENNA DIRECTLY TO THE RECEIVER
CABLE
ACCESS GRANTED INDICATOR
LIGHTS WHEN THE ACCESS RELAY IS ENERGIZED.
REMOTE WHIP ANTENNA
MOUNT THE F-81 CONNECTOR ON THE SURFACE USING THE LOCKWASHER AND NUT
CONNECT TO THE RECEIVER WITH THE COAX CABLE AND SCREW THE WHIP ANTENNA TO THE F-81 CONNECTOR
F-81
COAX TO RECEIVER
CONNECTOR
LIGHTS WHEN AC OR DC POWER IS APPLIED TO THE UNIT.
SUSPENDED INDICATOR
LIGHTS WHEN A SIGNAL IS RECEIVED FROM A TRANSMITTER THAT HAS BEEN
SUSPENDED FROM USE, AND WHEN SUSPENDING A TRANSMITTER.
PROGRAM MODE INDICATOR
LIGHTS WHEN THE UNIT IS IN PROGRAM MODE.
ATTACH WHIP ANTENNA TO THIS SIDE
SCREWS
F-81 CONNECTOR NUT AND LOCKWASHER
POWER INDICATOR
RADIO INDICATOR
LIGHTS WHEN A RADIO SIGNAL ON THE RECEIVER'S FREQUENCY IS DETECTED.
REMOTE FIXED ANTENNA
USE THE OPTIONAL EXA-1000 OR EXA-2000 ANTENNA MOUNTED AS HIGH AS POSSIBLE FOR THE BEST RADIO RANGE
CONNECT TO THE RECEIVER WITH AN RG-59 COAX CABLE
EXA-1000 ANTENNA
EXA-2000 DIRECTIONAL ANTENNA
SET FACILITY CODES SET TRANSMITTER BUTTONS ADDING TRANSMITTERS ACTIVATING/SUSPENDING TRANSMITTERS
USE THESE STEPS ONLY IF TRANSMITTER BLOCKS HAVE BEEN
ORDERED WITH A PRE-SET FACILITY CODE
PROGRAM
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
STEP 4: PRESS
STEP 5: PRESS
1. REPEAT STEPS 2-4, IF REQUIRED, FOR EACH OF THE FOUR RECEIVER FACILITY CODE LOCATIONS
2. WHEN THE TRANSMITTER FACILITY CODE IS SET TO "0", THE RECEIVER WILL ACCEPT ALL TRANSMITTERS REGARDLESS OF THEIR FACILITY CODE
FOR 3 SECONDS
THEN:
PROGRAM
EXITS PROGRAM MODE
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
FACILITY CODE FUNCTION NUMBER
RECEIVER FACILITY CODE LOCATION (FROM 1-4)
TRANSMITTER FACILITY CODE NUMBER
(FROM 1-15; 0 = IGNORE FACILITY CODE)
NOTES:
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
STEP 4: PRESS
1. THE FACTORY DEFAULT SETTING ONLY ALLOWS THE LEFT TRANSMITTER BUTTON TO ACTIVATE THE ACCESS RELAY
2. THE BUTTON SETTING WILL BE USED BY ALL TRANSMITTERS PROGRAMMED
3. REPEAT STEPS 2 & 3 TO PROGRAM OTHER BUTTONS
USE THESE STEPS TO CHANGE WHICH BUTTONS ON
MULTI-BUTTON TRANSMITTERS WILL ACTIVATE THE ACCESS RELAY
PROGRAM
FOR 3 SECONDS
THEN:
PROGRAM
EXITS PROGRAM MODE
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
TRANSMITTER BUTTON FUNCTION NUMBER
(ENTER 21-25: 21 = LEFT; 22 = RIGHT; 23 = TOP;
24 = LOWER LEFT; 25 = LOWER RIGHT)
OR
ENTER "1" TO ENABLE BUTTON ENTER "0" TO DISABLE BUTTON
NOTES:
PROGRAM
PROGRAM
FOR 3 SECONDS
THEN:
ENTERS ID #
COMPLETE
ID # ENTRY
EXITS
PROGRAM MODE
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
STEP 4: PRESS
SKIP TO STEP 6 FOR SINGLE TRANSMITTERS
STEP 5: PRESS
STEP 6: PRESS
REPEAT STEPS 2-6 TO ADD MORE TRANSMITTERS
STEP 7: PRESS
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
TRANSMITTER ADDING FUNCTION NUMBER
SINGLE TRANSMITTER ID #
OR STARTING TRANSMITTER
BLOCK ID # (FROM 1-65535)
ENDING TRANSMITTER
BLOCK ID # (FROM 1-65535)
IF THE TRANSMITTER ID # IS NOT LABELED ON A TRANSMITTER, TRIGGER THE TRANSMITTER TO VIEW THE ID # ON THE AP-4 DISPLAY. USE THE STAR KEY TO REVIEW THE LAST RECEIVED ID # (PRESS THE DISPLAY BUTTON TO VIEW THE LEFT THREE DIGITS OF THE ID #)
NOTE:
PROGRAM
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
STEP 4: PRESS
STEP 5: PRESS
1. REPEAT STEPS 2-4 TO SUSPEND OR ACTIVATE ADDITIONAL TRANSMITTERS
2. SUSPENDED TRANSMITTERS CAN NOT TRIGGER THE ACCESS RELAY, THE SUSPENDED INDICATOR WILL LIGHT INSTEAD
3. ACTIVATED TRANSMITTERS CAN TRIGGER THE ACCESS RELAY
FOR 3 SECONDS
THEN:
PROGRAM
EXITS PROGRAM MODE
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
TRANSMITTER STATUS FUNCTION NUMBER
OR
ENTER "0" TO SUSPEND XMTR
ENTER "1" TO ACTIVATE XMTR
NOTES:
REMOVING ALL TRANSMITTERS ADDING AN MGT TRANSMITTER MGT TRANSMITTER SUPERVISION SUSPENDING THE MGT TRANSMITTER
IF THE AP-4 BEEPS EVERY 5 SECONDS,
PROGRAM
PROGRAM
FOR 3 SECONDS
THEN:
EXITS
PROGRAM MODE
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
STEP 4: PRESS
DISPLAY: THEN:
STEP 5: PRESS
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
TRANSMITTER REMOVING FUNCTION NUMBER
REMOVE COMMAND
VERIFY REMOVE COMMAND
MEMORY CLEAR
1. WARNING! ALL TRANSMITTERS INCLUDING THE MGT TRANSMITTER WILL BE REMOVED
(TRANSMITTERS CANNOT BE INDIVIDUALLY REMOVED)
2. WARNING! ALL OTHER OPTIONS WILL BE RESET TO THE FACTORY DEFAULTS
NOTES:
PROGRAM
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
STEP 4: PRESS
STEP 5: PRESS
IF THE TRANSMITTER ID # IS NOT LABELED ON THE TRANSMITTER, TRIGGER THE TRANSMITTER TO VIEW THE ID # ON THE AP-4 DISPLAY. USE THE STAR KEY TO REVIEW THE LAST RECEIVED ID # (PRESS THE DISPLAY BUTTON TO VIEW THE LEFT THREE DIGITS OF THE ID #)
FOR 3 SECONDS
THEN:
ENTERS MGT ID #
PROGRAM
EXITS PROGRAM MODE
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
MGT TRANSMITTER ADDING FUNCTION NUMBER
MGT TRANSMITTER ID #
(FROM 1-65535)
NOTE:
PRESS
PRESS
THE MGT HAS SENT A SUPERVISORY SIGNAL
NOTE: WHEN THE MGT HAS A SUPERVISORY CONDITION, TRANSMITTERS
WILL HAVE TO BE TRIGGERED TWICE TO GAIN ACCESS
UTILTITY FUNCTION #1 TO DISPLAY MGT STATUS
"L--" INDICATES MGT TRANSMITTER LOW BATTERY
"-F-" INDICATES AN MGT TAMPER OR LOOP FAULT
"--S" INDICATES THAT HOURLY STATUS REPORTS HAVE NOT BEEN RECEIVED FROM THE MGT TRANSMITTER IN THE PREVIOUS FOUR HOURS
AFTER CLEARING "---" INDICATES THAT NO SUPERVISORY CONDITIONS EXIST WITH THE MGT TRANSMITTER
CANCEL
CLEARS MGT STATUS FROM AP-4 MEMORY AND STOPS BEEPER
REMOVING THE MGT TRANSMITTER SYSTEM TESTING SPECIFICATIONS
PROGRAM
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
DISPLAY: THEN:
STEP 4: PRESS
FOR 3 SECONDS
THEN:
PROGRAM
EXITS PROGRAM MODE
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
MGT TRANSMITTER FUNCTION NUMBER
REMOVE COMMAND
MGT REMOVED
ACTIVATE A TRANSMITTER THAT HAS BEEN PROGRAMMED (AND IS NOT SUSPENDED)
THE RADIO AND ACCESS GRANTED INDICATORS SHOULD LIGHT AND THE ACCESS DEVICE SHOULD OPERATE
IF AN MGT OBSTACLE TRANSMITTER IS PROGRAMMED, RUN THE ACCESS DEVICE AND TRIGGER THE OBSTACLE SENSOR
VERIFY THAT THAT ACCESS DEVICE REVERSES
IF AN OPEN REQUEST PUSHBUTTON IS INSTALLED, PRESS IT
THE ACCESS GRANTED INDICATOR SHOULD LIGHT AND THE ACCESS DEVICE SHOULD OPERATE
Size: 4.5” W x 6.0” H x 1.5” D
Supply Voltage: 12-24 Volts AC or DC
Operating Current: 250 mA Maximum
Operating Temperature Range: -22° to +158° F
(-30° to 70° C)
Sensitivity: -94 dBm Minimum
Bandwidth (3 db): 4 MHz Typical
Frequency: 318 MHz
Relay Contact Rating: 1 Amp @ 24 Volts
AC or DC
Maximum # of Transmitters: 480
Maximum # of Transmitter Blocks: 238
Maximum # of Facility Codes: 4
STEP 1: PRESS
DISPLAY:
STEP 2: PRESS
STEP 3: PRESS
DISPLAY: THEN:
STEP 4: PRESS
1. USE THE SAME COMMAND TO ACTIVATE (UNSUSPEND) THE MGT TRANSMITTER
2. SUSPENDING AN MGT WITH A SUPERVISORY CONDITION WILL ALLOW TRANSMITTERS TO GAIN ACCESS WITH ONE ACTIVATION INSTEAD OF TWO
This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of Linear corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signalling. However, there are some limitations which must be observed.
• The radios are required to comply with FCC Part 15 and Industry Canada Rules and Regulations.
• A receiver cannot respond to more than one transmitted signal at a time and may be blocked by
• Changes or modifi cations to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect against undetected
• A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
Copyright © 2007 Linear LLC 220159 C
TO DISABLE THE MGT SUPERVISION AND PREVENT
THE AP-4 FROM SOUNDING THE 5-SECOND MGT SUPERVISORY BEEPS
PROGRAM
FOR 3 SECONDS
THEN:
PROGRAM
EXITS PROGRAM MODE
ENTERS PROGRAM MODE
READY FOR PROGRAMMING
MGT TRANSMITTER FUNCTION NUMBER
SUSPEND/ACTIVATE COMMAND
MGT SUPERVISION CHANGED
(SUSPEND INDICATOR LIGHTS FOR
NOTES:
LINEAR LIMITED WARRANTY
IMPORTANT!!!
As such, they have limited transmitter power and therefore limited range.
radio signals that occur on or near their operating frequencies, regardless of code settings.
interference or fault.
distributor or dealer, and these facts should be communicated to the ultimate users.
TRANSMITTER ID #
(FROM 1-65535)
2 SECONDS WHEN MGT
HAS BEEN SUPSENDED)
Loading...