Linear AM-MIO RLM Owner's Manual

AM-MIO RLM
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
1
6
7
0
5
4
2
3
1
6
7
0
5
4
2
3
1
6
7
0
5
3
4
SLIDE MODULE INTO THE RACK
PRESS THE MODULE IN UNTIL IT SNAP
S
INTO PLAC
E
RELAY/LOOP
MODULE (RLM
)
RELAY
STATUS
INDICATORS
LOOP STATUS
INDICATO
R
DEVICE ADDRESS
SELECTO
R
MODULE
CONNECTOR
S
RELAY TRIGGER
PUSHBUTTONS
RELAY
OUTPUT
TERMINAL
S
LOOP INPU
T
TERMINAL
S
1
6
7
0
5
4
2
3
2
1
3
USE THE 10-WIRE CA BLE TO CONNECT THE NEW RELAY/LOOP MOD ULE TO THE EXISTIN
G
MODULE PRIOR TO IN STALLING
N.O.1COM
2
N.C.3N.O.4CO
M
5
N.C.6N.O.7CO
M
8
N.C.
9
N.O.
10
COM11N.C.12N.O.13COM14N.C.15N.O.16COM17N.C.
18
CHANNEL 1 CHANNEL 2 CHANNEL 3
CHANNEL 4 CHANNEL 5 CHANNEL
6
CONNECT RELAY OUTPUTS TO TH
E CONTROLLED DEVICE
S
RELAY RATING
:
5 AMPS
@
14 VD
C
MAXIMU
M
LOOP
1
1
CO
M
2
LOOP
2
3
LOOP
3
4
CO
M
5
LOOP
4
6
LOOP
5
7
COM8LOOP
6
9
LOOP
7
10
CO
M11LOOP
8
12
2.2K 2.2K 2.2K 2.2K
2.2K 2.2K 2.2K 2.2K
CONNECT ANY INPUTS TO THE LOOP INPUT TERMINAL
S
EACH LOOP INPUT CAN BE TRIGGERED WITH A NORMALLY OPEN OR NORMALLY CLOSED SWITCH
ALL LOOP INPUTS MUST BE TERMINATED WITH A 2.2K END-OF-LINE RESISTOR
EXAMPLE OF LOOPS 1-4 WITH NORMALLY CLOSED SWITCHE
S
EXAMPLE OF LOOPS 5-
8 WITH NORMALLY OPEN SWITCHE
S
LOOP
1
COM LOOP2LOOP3COM LOOP
4
2.2K 2.2K
2.2K 2.2K
4
5
6
1
2
3
LOOP
5
COM LOOP6LOOP7COM LOOP
8
2.2K 2.2K
2.2K 2.2K
10
11
12
7
8
9
CHANNEL 2 CHANNEL
3
7
8
9
4
5
6
16
17
18
13
14
15
N.O.
CHANNEL
1
2
3
1
11
12
10
COM N.C. N.O. COM N.C. N.O.
COM N.C.
CHANNEL 5 CHANNEL
6
N.O.
CHANNEL 4
COM N.C. N.O. COM N.C. N.O.
COM N.C.
RELAY OUTPUT TERMINALS
RELAY OUTPUT TERMINAL
S
LOOP INPUT TERMINAL
S
LOOP INPUT TERMINAL
S
ALL LOOP INPUTS MUST BE
TERMINATED WITH A 2.2K
END-OF-LINE RESISTOR
CONTROLLED DEVICE "4"
CONTROLLED DEVICE "5"
CONTROLLED DEVICE "6"
CONTROLLED DEVICE "1"
CONTROLLED DEVICE "2"
CONTROLLED DEVICE "3"
AM-MIO RLM WIRING DIAGRAM
NOTE: RLM DEFAULT ADDRESS IS "4
"
THE ARROW IN THE SELECTOR SWITCH SLOT POINTS TO THE ADDRESS NUMBER (ADDRESS NUMBERS 1-6 AR
E
VALID)
SET THE MODULE TO A DIFFERENT DEVICE ADDRESS FROM THE EXISTING MODULES.
PRODUCT DESCRIPTION
Up to three additional RLM modules can be added to fill the five-position module “rack”. Each RLM module provides six Form “C” (normally open
MODULE FEATURES
Relay/Loop Module (RLM)
controlling 24 relay outputs and 32 loop inputs. Each module has a rotary switch to select its unique remote device address. The device address identifies each module to the system. Each module is interconnected to the controller by daisy-chained cables.
For Use With the AM-3, AE-1000, & AE-2000 Access Control Systems
Pushbuttons on the RLM module are provided for manually triggering each relay for testing. Each relay has a red LED light to show when it’s energized. A two-color red/green LED on the RLM module displays the status of the loop inputs. If all eight loops are “normal” (not shorted or
Installation Instructions
open) the indicator is green. If any of the eight loops are “abnormal” (shorted or open) the indicator is red. The power supply module (PSM) from the AM-MIO distributes power to the RLM module(s). An external 16 VAC transformer powers the supply and provides charging current for a 12-volt backup battery (up to 7 amp/ hour capacity).
SETTING DEVICE ADDRESSES CONNECTING MODULES ADDING MODULE
WIRING DIAGRAM
CONNECT RELAY OUTPUTS CONNECT LOOP OUTLETS LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twenty four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to
wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied
warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express
or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Service at 1-800-421-1587 for an RPA# and other important details.
Linear radio controls provide a reliable communications link and fill an impor tant need in por table wireless signalling. However, there are some limitations which must be observed.
• For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as
• A receiver cannot respond to more than one transmitted signal at a time and may be blocked by
• Changes or modifications to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect against undetected interference
• A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
Part 15 devices. As such, they have limited transmitter power and therefore limited range.
radio signals that occur on or near their operating frequencies, regardless of code settings.
or fault.
distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2004 Linear LLC 218308 B
IMPORTANT