AM-MIO
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
POWER
SUPPLY
MODULE
(PSM
)
NOTE: ILLUSTRATION SHOWS FOUR
RELAY/LOOP MODULES, ONLY ON
E
MODULE IS INCLUDED WITH THE AM-MIO
RELAY/LOOP MODULES (RLM)
(FOUR MODULES MAXIMUM
)
BACKUP BATTERY
12 VOLT 7 AMP/HOUR
MAXIMUM
(NOT INCLUDED)
MODULE
MOUNTING
RACKS
CAREFULLY ROUTE THE BATTERY
LEADS UNDER MODULE RACK
AS SHOW
N
1
2
SLIDE MODULES OUT
OF THE RACK
PSM
RL
M
1
2
3
PLACE COVER ON
CARPET AND PUNC
H
OUT KEY LOCK
KNOCKOUT
INSERT LOCK INTO COVER
TIGHTEN NUT
RELAY/LOOP
MODULE (RLM
)
POWER SUPPL
Y
MODULE (PSM
)
BACKUP
BATTER
Y
LEAD
S
DEVICE
ADDRESS
SELECTOR
DATA
POWER SUPPLY
STATUS
INDICATORS
TAMPER
LOW BATTER
Y
AC POWE
R
TAMPER
SWITCH
CONNECTOR
MODULE
CONNECTOR
CONTROLLER
CONNECTOR
POWER
TERMINALS
AUXILIARY
PBUS
TERMINAL
S
RELAY
STATUS
INDICATORS
LOOP STATUS
INDICATO
R
DEVICE ADDRESS
SELECTO
R
MODULE
CONNECTOR
S
RELAY TRIGGER
PUSHBUTTONS
RELAY
OUTPUT
TERMINALS
LOOP
INPU
T
TERMINALS
USE THE CABINET BOTTOM AS
A TEMPLATE TO MARK THE
FOUR KEYHOLE MOUNTING
HOLE
S
FOR RECESSED WIRING,
MARK WIRING SLOT
,
THEN CUT OUT HOLE
WITH DRYWALL SA
W
FOR CONDUIT WIRING
,
REMOVE ANY CABINE
T
KNOCKOUTS BEFORE
MOUNTING THE CABINE
T
USE THE APPROPRIAT
E
HARDWARE TO MOUNT
THE CABINE
T
NOTE:
PSM DEFAULT
ADDRESS IS "5"
NOTE:
RLM DEFAULT
ADDRESS IS "4
"
THE ARROW IN THE
SELECTOR SWITCH
SLOT POINTS TO
THE ADDRESS
NUMBER (ADDRESS
NUMBERS 1-6 AR
E
VALID)
SET EACH MODULE
TO A DIFFERENT
DEVICE ADDRESS
(ONLY REQUIRED IF
ADDRESS OTHE
R
THAN DEFAULT IS
DESIRED)
RELAY/LOOP
MODUL
E
POWER SUPPL
Y
MODUL
E
CONNECT POWER SUPPLY
TO RELAY/LOOP MODUL
E
WITH THE 10-WIRE CABL
E
TO KEEP THE BATTERY LEADS
AWAY FROM THE POWER SUPPL
Y
HEAT SINK, ROUTE THE BATTERY
LEADS UNDER MODULE RACK
AS SHOW
N
1
2
3
SLIDE MODULES INTO RACK
PRESS THE MODULES IN UNTI
L
THEY SNAP INTO PLAC
E
PSM
RL
M
1
2
3
REMOVE THE OPTIONAL JUMPER
FROM THE TAMPER SWITCH
CONNECTOR
INSTALL THE TAMPER SWITCH
IN THE BOTTOM CORNER OF
CABINET AND CONNECT TH
E
WIRE TO THE TAMPER
SWITCH CONNECTO
R
ATTACH THE MAGNET TO THE CABINET
COVER SO IT WILL ALIGN WITH TH
E
TAMPER SWITCH WHEN THE COVER IS
CLOSED
PLUG CABLE FROM AM-MIO PSM CONTROLLER
CONNECTOR INTO THE CONTROLLER'S AM-MIO
INTERFACE CONNECTOR (MODEL AM-3
CONTROLLER SHOWN)
TO AM-MIO PSM
OPTIONAL: USE THE PSM AUXILIARY PBUS TERMINALS TO
CONNECT TO THE CONTROLLER'S AUXILIARY PBUS TERMINALS.
REFERENCE THE PSM WIRING DIAGRAM. CABLE TYPE IS
BELDEN 9931 (300 FEET MAX. CABLE RUN) OR WEICO 9405
(500 FEET MAX. CABLE RUN).
Input-Output
Expansion Interface
For Use With the AM-3, AE-1000, & AE-2000
Access Control Systems
Installation Instructions
PRODUCT DESCRIPTION
The AM-MIO is an expandable input/output interface designed for use with Linear’s
AM-3, AE-1000, & AE-2000 access control systems. Housed in a lockable cabinet,
the basic AM-MIO consists of two modules: a power supply module (PSM) and a
relay/loop module (RLM). Up to three additional RLM modules can be added to fill the
five-position module “rack”. Each RLM module provides six Form “C” (nor mally open
& normally closed) 5-amp relays for outputs and eight supervised loop terminals for
inputs. With four RLM modules, the AM-MIO is capable of controlling 24 relay outputs
and 32 loop inputs. Each module has a rotary switch to select its unique remote device
address. The device address identifies each module to the system. Each module is
interconnected to the controller by daisy-chained cables.
Pushbuttons on the RLM module are provided for manually triggering each relay for
testing. Each relay has a red LED light to show when it’s energized. A two-color red/
green LED on the RLM module displays the status of the loop inputs. If all eight loops
are “normal” (not shorted or open) the indicator is green. If any of the eight loops are
“abnormal” (shorted or open) the indicator is red.
The power supply module distributes power to the RLM module(s). An external 16
VAC transformer powers the supply and provides charging current for a 12-volt backup
battery (up to 7 amp/hour capacity). Indicators on the power supply module display
its status. The green indicator lights when AC power is present and blinks when AC
power is absent. The yellow indicator lights when the backup battery is low. Special
power circuitry prevents fully discharging the backup batter y. The status of the power
supply is checked regularly by the controller. The red DATA indicator lights when data
transfers. The red TAMPER indicator lights and the controller is signaled when the
optional magnetic tamper switch detects that the cabinet has been opened.
CABINET COMPONENTS
MODULE FEATURES KEY LOCK INSTALLATION (OPTIONAL) REMOVING MODULES
MOUNTING CABINET SETTING DEVICE ADDRESSES CONNECTING MODULES
INSTALLING MODULES CONNECTING TAMPER SWITCH (OPTIONAL) CONNECT TO ACCESS CONTROLLER
CONNECT RELAY OUTPUTS CONNECT LOOP INPUTS CONNECT AC POWER
N.O.1COM
2
N.C.3N.O.4CO
M
5
N.C.6N.O.7CO
M
8
N.C.
9
N.O.
10
COM11N.C.12N.O.13COM14N.C.15N.O.16COM17N.C.
18
CHANNEL 1 CHANNEL 2 CHANNEL 3
CHANNEL 4 CHANNEL 5 CHANNEL
6
CONNECT RELAY
OUTPUTS TO TH
E
CONTROLLED
DEVICE
S
RELAY RATING
:
5 AMPS
@
14 VD
C
MAXIMU
M
LOOP
1
1
CO
M
2
LOOP
2
3
LOOP
3
4
CO
M
5
LOOP
4
6
LOOP
5
7
CO
M
8
LOOP
6
9
LOOP
7
10
CO
M11LOOP
8
12
2.2K 2.2K 2.2K 2.2K
2.2K 2.2K 2.2K 2.2K
CONNECT ANY INPUTS TO THE
LOOP INPUT TERMINAL
S
EACH LOOP INPUT CAN BE
TRIGGERED WITH A NORMALLY
OPEN OR NORMALLY CLOSED
SWITCH
ALL LOOP INPUTS MUST BE
TERMINATED WITH A 2.2K
END-OF-LINE RESISTOR
EXAMPLE OF LOOPS 1-4
WITH NORMALLY
CLOSED SWITCHE
S
EXAMPLE OF LOOPS 5-
8
WITH NORMALLY
OPEN SWITCHE
S
AC
IN
1
AC
IN
2
EART
H
GND
3
DATA
GN
D
4
POWER
TERMINAL
S
16 VAC, 24 VA MIN.
POWE
R
TRANSFORME
R
UNIFIED
EARTH
GROUND
CONNECT 16 VAC
POWER FROM PLUG-I
N
TRANSFORMER TO
POWER TERMINAL
S
1 &
2
CONNECT A GOOD
EARTH GROUND TO
POWER TERMINAL
3
NOTE: DATA GROUND
TERMINAL IS USED ONLY
WHEN CONNECTING
TO THE CONTROLLE
R
THROUGH TH
E
CONTROLLER AUXILIARY
PBUS TERMINALS
PLACE THE BACKUP
BATTERY IN THE CABINE
T
CONNECT THE RED LEAD TO BATTERY POSITIVE (+)
CONNECT THE BLACK LEAD TO BATTERY NEGATIVE (-)
PRESS THE RELAY
TRIGGER BUTTONS
TO TEST EACH RELA
Y
CONNECTED
THE RELAY STATUS
INDICATOR WILL
LIGHT WHEN TH
E
RELAY IS ENERGIZED
CAUTION!
DEVICES CONNECTED TO
THE RELAYS WILL ACTIVATE
WATCH THE LOOP
STATUS INDICATO
R
WHILE TESTING THE LOOP
S
GREEN = ALL LOOPS NORMAL
RED = ANY LOOP OPEN OR SHORTE
D
LOOP
1
COM LOO
P
2
LOOP3COM LOOP
4
2.2K 2.2K
2.2K 2.2K
4
5
6
1
2
3
LOOP
5
COM LOO
P
6
LOOP7COM LOOP
8
2.2K 2.2K
2.2K 2.2K
10
11
12
7
8
9
CHANNEL 2 CHANNEL
3
7
8
9
4
5
6
16
17
18
13
14
15
N.O.
CHANNEL
1
2
3
1
11
12
10
COM N.C. N.O. COM N.C. N.O. COM N.C
.
CHANNEL 5 CHANNEL
6
N.O.
CHANNEL 4
COM N.C. N.O. COM N.C. N.O. COM N.C
.
POWER TERMINALS
AC
INACIN
EARTH
GND
DATA
GND
DAT1 DAT0 DVAL PCLK
AUXILIARY PBUS TERMINALS
RELAY OUTPUT TERMINAL
S
RELAY OUTPUT TERMINAL
S
LOOP INPUT TERMINAL
S
LOOP INPUT TERMINAL
S
ALL LOOP INPUTS MUST BE
TERMINATED WITH A 2.2K
END-OF-LINE RESISTOR
CONTROLLED DEVICE "4"
CONTROLLED DEVICE "5"
CONTROLLED DEVICE "6"
CONTROLLED DEVICE "1"
CONTROLLED DEVICE "2"
CONTROLLED DEVICE "3"
16 VAC, 24 VA
MINIMU
M
TRANSFORMER
EARTH
GROUND
STAKE
CONTROLLER PBUS TERMINALS
6
7
8
5
4
3
2
1
POWER SUPPLY
MODULE (PSM
)
RELAY/LOOP
MODULE (RLM)
AM-MIO RLM WIRING DIAGRAM
AM-MIO PSM WIRING DIAGRAM
12 VDC
BACKUP
BATTERY
+ RED WIRE
- BLACK WIRE
NOTE: OPTIONAL AM-MIO PSM TO CONTROLLER WIRING
SHOWN WHEN NOT USING THE INCLUDED CABL
E
1. PROGRAM THE ACCESS
CONTROL SYSTEM. BE
SURE TO PROGRAM TH
E
SYSTEM FOR THE DEVICE
ADDRESS OF EACH OF TH
E
AM-MIO MODULES.
2. USE ENTRY CODES OR
TRANSMITTERS TO TEST
ACTIVATE EACH OF TH
E
AM-MIO OUTPUT
S
3. TEST TO SEE IF EACH OF
THE AM-MIO LOOP INPUTS
(IF USED) ARE RECOGNIZED
BY THE ACCESS CONTRO
L
SYSTEM
CONNECT BACKUP BATTERY TEST RELAYS TEST LOOPS
WIRING DIAGRAM
TEST SYSTEM LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and
workmanship for twenty four (24) months. The Warranty Expiration
Date is labeled on the product. This warranty extends only to
wholesale customers who buy direct from Linear or through Linear’s
normal distribution channels. Linear does not warrant this product
to consumers. Consumers should inquire from their selling dealer as
to the nature of the dealer’s warranty, if any. There are no obligations
or liabilities on the part of Linear LLC for consequential damages
arising out of or in connection with use or performance of this
product or other indirect damages with respect to loss of property,
revenue, or profit, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and
implied warranties for fitness, are valid only until Warranty Expiration Date
as labeled on the product. This Linear LLC Warranty is in lieu of all
other warranties express or implied.
All products returned for warranty service require a Return Product
Authorization Number (RPA#). Contact Linear Technical Service at 1-800421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an
important need in portable wireless signalling. However, there are some
limitations which must be observed.
• For U.S. installations only: The radios are required to comply with FCC
Rules and Regulations as Part 15 devices. As such, they have limited
transmitter power and therefore limited range.
• A receiver cannot respond to more than one transmitted signal at a
time and may be blocked by radio signals that occur on or near their
operating frequencies, regardless of code settings.
• Changes or modifications to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect
against undetected interference or fault.
• A general knowledge of radio and its vagaries should be gained prior
to acting as a wholesale distributor or dealer, and these facts should be
communicated to the ultimate users.
Copyright © 2004 Linear LLC 218307 B