The Model AE-2 Telephone Entry Con trol Console is des igned for use as a pri mary access control device for gated communities, parking garages, office buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities.
AE-2
This unit is a fusion of Linear’s full-featured Model AM/II Access Control System and the Model AE-2 Telephone Entry Module. Housed in a locked, rugged stainless steel
Telephone Entry Control Console
enclosure, the AE-2 features a 12-key telephone style keypad, a vacuum florescent two-line directory display, and a built-in microphone and speaker.
All of the outstanding AM/II access control system functions are available with the AE-2 in addition to hands-free, full duplex telephone communications with tenants or authorized personnel for granting access. Entry codes can also be typed directly on the keypad.
In a typical installat ion, the unit’s mem ory would be program med with each tenant ’s name and directory code number. A visitor would use the view the director y names and code numb er for the desir ed party. Upon en tering the
or # key on the AE-2 to
*
directory number, the AE-2 will automatically dial the tenant’s telephone number and establish two-way voice communication between the visitor and the tenant . T h e ten a n t will then have the option to grant access to the guest by pressing a digit on their telephone.
In addition to the telephone entry, the AE-2 can grant access using various remote devices that are commonly used with the AM/II. These devices include wireless transmitters, proximity receivers, swipe card readers and remote keypads.
Mechanical & Electrical Installation Instructions
The output relays can be programmed to control electric door strikes, door & gate operators, barrier gates. CCTV cameras can also be triggered by the output relays to monitor the entry areas.
All of the programming functions of the AE-2 can be performed directly through the unit’s keypad. An optional telephone modem can be installed for easy remote
(760) 438-7000 FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
programming with a personal computer. The AE-2 cabinet has provisions for installing a postal lock for keyed mail carrier access.
The postal lock can be programmed to activate any of the four output relays.
2. AE-2 COMPONENT LOCATIONS 3. DETERMINE MOUNTING LOCATION 4. MOUNT CABINET
MODULAR TELEPHONE JACK (HIDDEN)
HYBRID LEVEL ADJUSTMENT (FACTORY SET DO NOT ADJUST)
SPEAKER VOLUME ADJUSTMENT
SPEAKER CONNECTOR
AE-2 TO AM/II INTERCONNECT CABLE
TELEPHONE LINE TERMINALS
TEST JUMPER (REMOVE TO HEAR UNIT DIAL)
MICROPHONE & POSTAL KEY SWITCH TERMINALS
BUSY INDICATOR (LIGHTS WHEN AE-2 IS COMMUNICATING OR WHEN PHONE LINE IS DISCONNECTED)
ON-LINE INDICATOR (LIGHTS WHEN PHONE LINE IS ACTIVE)
DISPLAY CONTRAST ADJUSTMENT (NOT USED ON THIS MODEL)
THE AE-2 SHOULD BE MOUNTED IN A WELL LIT LOCATION NEAR THE CONTROLLED OPENING. WIRING ACCESS FOR POWER, TELEPHONE, EARTH GROUND, CONTROL OUTPUT AND ANTENNA CO-AX MUST BE AVAILABLE BEHIND THE MOUNTING LOCATION.
AREA LIGHTING
AE-2 TELEPHONE ENTRY SYSTEM
CONTROLLED ENTRY DOOR
5 3/8" 5 3/8"
5 3/8" 5 3/8"
MOUNTING LOCATION
9 3/8"
MOUNT CABINET WITH SUITABLE HARDWARE FOR MOUNTING SURFACE.
USE TOGGLE BOLTS FOR STUCCO WALL, WEDGE ANCHORS OR EXPANSION BOLTS FOR CONCRETE WALL, LAG SCREWS FOR WOOD WALL.
5. CONNECT WIRING 6. OPTIONAL MODEM INSTALLATION 7. OPTIONAL POSTAL LOCK INSTALLATION
REFER TO THE AM/II INSTALLATION & PROGRAMMING INSTRUCTIONS FOR DETAILS ON WIRING POWER, EARTH GROUND, REMOTE DEVICES, ANTENNA, CONTROL INPUTS AND RELAY OUTPUTS TO THE AM/II
RELAY OUTPUT TO ACCESS DEVICE
POWER INPUT TO TRANSFORMER
EARTH GROUND CONNECTION
USE LOWER WIRING HOLE IF MODEM IS GOING TO BE INSTALLED
TELEPHONE LINE (USE MODULAR JACK OR TERMINALS)
CONNECT UNITS WITH THE MODEL A2M MODEM CABLE
CONNECT INCOMING TELEPHONE LINE TO THE MODEM'S "LINE" JACK
NOTE: SEPARATE PHONE LINES ARE RECOMMENDED FOR THE MODEM AND AE-2. ONE PHONE LINE CAN BE USED AS SHOWN ALTHOUGH THE ENTRY SYSTEM IS UNAVAILABLE WHILE MODEM IS ON-LINE.
ATTACH MODEM WITH VELCRO ® STRIPS (SEE MODEM INSTALLATION INSTRUCTIONS)
USE THE TELEPHONE CABLE SUPPLIED WITH THE MODEM TO CONNECT BETWEEN THE MODEM'S "PHONE" JACK AND THE AE-2 TELEPHONE LINE JACK
CONNECT MODEM TRANSFORMER POWER CABLE AND TURN MODEM SWITCH ON
1
BARRIER PLATE
BEND UP TABS ON THE HOLE PLUG AND REMOVE THE PLUG
3
REMOVE THE TWO NUTS AND THE POSTAL LOCK BARRIER PLATE
2
INSTALL THE POSTAL LOCK USING FOUR 10-32 NUTS
VERIFY THAT THE LOCK STRIKE ACTIVATES THE MICRO SWITCH
8. PROGRAM SYSTEM 9. ADJUST SPEAKER VOLUME & TESTING LINEAR LIMITED WARRANTY
INSTALLERS OF AE-2 SYSTEMS SHOULD FAMILIARIZE THEMSELVES WITH THE AM/II SYSTEM BY READING THE ENTIRE AM/II INSTALLATION & PROGRAMMING INSTRUCTIONS. PROGRAM AREAS SPECIFIC TO THE AE-1 ARE AREAS 07 &
27. AREA 21 HAS TWO OPTIONS FOR THE AE-2. PROGRAMMING WITH A PERSONAL COMPUTER IS RECOMMENDED, ESPECIALLY FOR ENTERING THE TENANT NAMES.
AREA 21
RELAY SETUP
Which Relay to Program. CH-A CH-B CH-C CH-D
Select Operation: Control Shunt Alarm Obstacle CCTV
Select Timing Mode: Time Pulse Toggle Latch
Enter Activation Time: Time in seconds: 00000
Assign Time Zone [1]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [2]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [3]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [4]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Enter Channel Name
Assign Telephone Digit None 1 2 3 4 5 6 7 8 9
Channel Control Normal Activate LockOpen LockClosed
21.1
21.2
21.3
21.4
21.5
21.6
21.7
21.8
21.9
21.10
21.11
AREA 07
TELEPHONE ENTRY NUMBERS
Enter Directory Code Directory Code: 0000
Enter Tenant Name
Enter Telephone Number Telephone#: ************
Extended Talk Time Yes No
Delete Directory Entry Directory Code: 0000
AREA 27
TELEPHONE ENTRY SETUP
Directory Code Length 1 2 3 4
Directory Begins At Beginning(A) Middle(M)
PBX Dialing Digit Off 9 8 7 6 5 4 3 2 1 0
Set Talk Time Talk Time Seconds: 060
Assign Postal Key Door CH-A CH-B CH-C CH-D
Sort Directory Names Yes No
Edit Display Messages Message Number: 00
Edit Display Message
Max Directory Entries Maximum Entries: 00000
Delete All Tlph. Entries Yes No
Adjust Hybrid Level Press OK To Start/Stop
Display Briteness Dim Low Med High
Priority Access ABCD 0 = No 1 = Yes 0000
7.1
7.2
7.3
7.4
7.5
27.1
27.2
27.3
27.4
27.5
27.6
27.7
27.8
27.9
27.10
27.11
27.12
27.13
1
REMOVE TEST JUMPER
ADJUST THE SPEAKER VOLUME AND DISPLAY CONTRAST TO SUIT THE ENVRONMENT THE UNIT IS MOUNTED IN
3
5
VERIFY THAT THE PROPER RELAY ACTIVATES AND THAT THE ACCESS DOOR STRIKE OR GATE CONTROL ACTIVATES
2
PRESS # TO VIEW DIRECTORY AND ENTER CODE TO DIAL A TEST PHONE NUMBER
4
HAVE TESTING PARTY PRESS ASSIGNED TELEPHONE DIGIT (DEFAULT IS 9) TO GRANT ACCESS
6
REPLACE THE TEST JUMPER, LOCK THE CABINET AND INSTRUCT FACILITY MANAGER ON SYSTEM USE
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribut ion chann els. Linear does not warrant this product to consumers. Consumers should inquir e from their selling dealer as to the nature of the de aler’s warranty, if any. There are no obligations or liabilities on the part of Linear
Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All
implied warranties, including implied warranties for merchantability and implied warranties for f itness, ar e valid only unti l Warranty Expirati on Date as lab eled on the product. This Linear Corporation Warranty is in lieu of all other warranties express
or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wirel ess signaling. However, there are some lim itations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulat ion s as Part 15
devices. As such, they have limited transmitter power and therefore limited ran ge. A receiver cannot respond to more than one transmitt ed signa l at a time and ma y be blocked by rad io signals
that occur on or near their operating f requen cie s, re gardle ss of code set tin gs. Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regu larly to pro te ct ag ainst und et ecte d int er f ere nce or fa ult .
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or
dealer, and these facts should be communicated to the ultima te users.
Copyright © 1999 Linear Corporation 215314 C