INTRODUCTION
1. SYSTEM COMPONENT LOCATIONS
The Model AE-1 Telephone Entry Control Console is designed for use as a primary
access control device for gated communities, parking garages, office buildings,
AE-1
apartments, dormitories, hotels/motels, commercial buildings and recreational facilities.
This unit is a fusion of Linear’s full-featured Model AM/II Access Control System and
AM/II ACCESS
CONTROL SYSTEM
the Model AE-1 Telephone Entry Module. Housed in a locked, rugged stainless steel
Telephone Entry Control Console
enclosure, the AE-1 features a 12-key telephone style keypad, a backlit two-line
directory display, and a built-in microphone and speaker.
All of the outstanding AM/II access control system functions are available with the AE-1 in
addition to hands-free, full duplex telephone communications with tenants or authorized
personnel for granting access. Entry codes can also be typed directly on the keypad.
In a typical installation, the unit’s memory would be programmed with each tenant’s
name and directory code number. A visitor would use the
the directory names and code number for the desired party. Upon entering the directory
or # key on the AE-1 to view
*
number, the AE-1 will automatically dial the tenant’s telephone number and establish
two-way voice communication between the visitor and the tenant. The tenant will then
have the option to grant access to the guest by pressing a digit on their telephone.
SPEAKER
In addition to the telephone entry, the AE-1 can grant access using various remote
devices that are commonly used with the AM/II. These devices include wireless
transmitters, proximity receivers, swipe card readers and remote keypads.
Mechanical & Electrical
Installation Instructions
The output relays can be programmed to control electric door strikes, door & gate
operators, barrier gates. CCTV cameras can also be triggered by the output relays to
monitor the entry areas.
All of the programming functions of the AE-1 can be performed directly through the
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
unit’s keypad. An optional telephone modem can be installed for easy remote
programming with a personal computer.
The AE-1 cabinet has provisions for installing a postal lock for keyed mail carrier access.
The postal lock can be programmed to activate any of the four output relays.
POSTAL LOCK
LOCATION
(LOCK OPTIONAL)
2. AE-1 COMPONENT LOCATIONS 3. DETERMINE MOUNTING LOCATION 4. MOUNT CABINET
POSTAL LOCK
SWITCH
MODEM
(OPTIONAL)
AE-1 TELEPHONE
ENTRY MODULE
MICROPHONE
(HIDDEN)
TELEPHONE
MODULAR
TELEPHONE
JACK (HIDDEN)
HYBRID LEVEL
ADJUSTMENT
(FACTORY SET
DO NOT ADJUST)
SPEAKER
VOLUME
ADJUSTMENT
SPEAKER
CONNECTOR
AE-1 TO AM/II
INTERCONNECT
CABLE
ON-LINE INDICATOR
(LIGHTS WHEN PHONE
LINE IS ACTIVE)
LINE TERMINALS
MICROPHONE
& POSTAL KEY
SWITCH TERMINALS
TEST JUMPER
(REMOVE TO
HEAR UNIT DIAL)
BUSY INDICATOR
(LIGHTS WHEN AE-1 IS
COMMUNICATING OR WHEN
PHONE LINE IS DISCONNECTED)
DISPLAY
CONTRAST
ADJUSTMENT
THE AE-1 SHOULD BE MOUNTED IN A WELL LIT LOCATION NEAR THE
CONTROLLED OPENING. WIRING ACCESS FOR POWER, TELEPHONE,
EARTH GROUND, CONTROL OUTPUT AND ANTENNA CO-AX MUST BE
AVAILABLE BEHIND THE MOUNTING LOCATION.
AREA
LIGHTING
AE-1
TELEPHONE
ENTRY SYSTEM
CONTROLLED
ENTRY DOOR
5 3/8" 5 3/8"
5 3/8" 5 3/8"
MOUNTING
LOCATION
9 3/8"
MOUNT CABINET WITH
SUITABLE HARDWARE FOR
MOUNTING SURFACE.
USE TOGGLE BOLTS FOR
STUCCO WALL, WEDGE
ANCHORS OR EXPANSION
BOLTS FOR CONCRETE
WALL, LAG SCREWS FOR
WOOD WALL.
5. CONNECT WIRING 6. OPTIONAL MODEM INSTALLATION 7. OPTIONAL POSTAL LOCK INSTALLATION
REFER TO THE AM/II INSTALLATION & PROGRAMMING
INSTRUCTIONS FOR DETAILS ON WIRING POWER, EARTH
GROUND, REMOTE DEVICES, ANTENNA, CONTROL INPUTS AND
RELAY OUTPUTS TO THE AM/II
RELAY OUTPUT
TO ACCESS
DEVICE
POWER INPUT
TO TRANSFORMER
EARTH
GROUND
CONNECTION
USE LOWER
WIRING HOLE
IF MODEM IS
GOING TO BE
INSTALLED
TELEPHONE
LINE (USE
MODULAR
JACK OR
TERMINALS)
CONNECT UNITS
WITH THE MODEL
A2M MODEM CABLE
CONNECT
INCOMING
TELEPHONE
LINE TO THE
MODEM'S
"LINE" JACK
NOTE: SEPARATE PHONE LINES ARE
RECOMMENDED FOR THE MODEM AND AE-1.
ONE PHONE LINE CAN BE USED AS SHOWN
ALTHOUGH THE ENTRY SYSTEM IS
UNAVAILABLE WHILE MODEM IS ON-LINE.
ATTACH MODEM
WITH VELCRO ® STRIPS
USE THE TELEPHONE CABLE
SUPPLIED WITH THE MODEM TO
CONNECT BETWEEN THE
MODEM'S "PHONE" JACK AND THE
AE-1 TELEPHONE LINE JACK
CONNECT MODEM
TRANSFORMER
POWER CABLE
AND SLIDE MODEM
POWER SWITCH TO "1"
1
BARRIER PLATE
BEND UP TABS ON
THE HOLE PLUG AND
REMOVE THE PLUG
3
REMOVE THE TWO NUTS
AND THE POSTAL LOCK
BARRIER PLATE
2
INSTALL THE POSTAL
LOCK USING FOUR
10-32 NUTS
VERIFY THAT THE LOCK
STRIKE ACTIVATES THE
MICRO SWITCH
8. PROGRAM SYSTEM 9. ADJUST SPEAKER VOLUME & TESTING LINEAR LIMITED WARRANTY
INSTALLERS OF AE-1 SYSTEMS SHOULD
FAMILIARIZE THEMSELVES WITH THE
AM/II SYSTEM BY READING THE ENTIRE
AM/II INSTALLATION & PROGRAMMING
INSTRUCTIONS. PROGRAM AREAS
SPECIFIC TO THE AE-1 ARE AREAS 07 &
27. AREA 21 HAS TWO OPTIONS FOR THE
AE-1. PROGRAMMING WITH A PERSONAL
COMPUTER IS RECOMMENDED,
ESPECIALLY FOR ENTERING THE TENANT
NAMES.
AREA 21
RELAY SETUP
Which Relay to Program.
CH-A CH-B CH-C CH-D
Select Operation:
Control Shunt Alarm Obstacle CCTV
Select Timing Mode:
Time Pulse Toggle Latch
Enter Activation Time:
Time in seconds: 00000
Assign Time Zone [1]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [2]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [3]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [4]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Enter Channel Name
Assign Telephone Digit
None 1 2 3 4 5 6 7 8 9
Channel Control
Normal Activate LockOpen LockClosed
21.1
21.2
21.3
21.4
21.5
21.6
21.7
21.8
21.9
21.10
21.11
AREA 07
TELEPHONE ENTRY NUMBERS
Enter Directory Code
Directory Code: 0000
Enter Tenant Name
Enter Telephone Number
Telephone#: ************
Extended Talk Time
Yes No
Delete Directory Entry
Directory Code: 0000
AREA 27
TELEPHONE ENTRY SETUP
Directory Code Length
1 2 3 4
Directory Begins At
Beginning(A) Middle(M)
PBX Dialing Digit
Off 9 8 7 6 5 4 3 2 1 0
Set Talk Time
Talk Time Seconds: 060
Assign Postal Key Door
CH-A CH-B CH-C CH-D
Sort Directory Names
Yes No
Edit Display Messages
Message Number: 00
Edit Display Message
Max Directory Entries
Maximum Entries: 00000
Delete All Tlph. Entries
Yes No
Adjust Hybrid Level
Press OK To Start/Stop
Display Briteness
Dim Low Med High
Priority Access ABCD
0 = No 1 = Yes 0000
7.1
7.2
7.3
7.4
7.5
27.1
27.2
27.3
27.4
27.5
27.6
27.7
27.8
27.9
27.10
27.11
27.12
27.13
1
REMOVE
TEST JUMPER
ADJUST THE
SPEAKER VOLUME
AND DISPLAY
CONTRAST TO SUIT
THE ENVRONMENT
THE UNIT IS
MOUNTED IN
3
5
VERIFY THAT THE
PROPER RELAY
ACTIVATES AND
THAT THE ACCESS
DOOR STRIKE OR
GATE CONTROL
ACTIVATES
2
PRESS # TO VIEW
DIRECTORY AND
ENTER CODE TO
DIAL A TEST
PHONE NUMBER
4
HAVE TESTING
PARTY PRESS
ASSIGNED
TELEPHONE
DIGIT (DEFAULT
IS 9) TO GRANT
ACCESS
6
REPLACE THE TEST JUMPER,
LOCK THE CABINET AND
INSTRUCT FACILITY MANAGER
ON SYSTEM USE
This Linear product is warrant ed against defects in material and workmanship for twelve
(12) months. The Warranty Expiration Date is labeled on the product. This warranty
extends only to wholesale customers who buy direct from Linear or through Linear’s
normal distribution channels. Linear does not warrant this product to consumers.
Consumers should inquire from their selling dealer as to the nature of the dealer’s
warranty, if any. There are no obligations or liabilities on the part of Linear
Corporation for consequential damages arising out of or in connection with use
or performance of this product or other indirect damages with respect to loss of
property, revenue, or profit, or cost of removal, installation, or reinstallation. All
implied warranties, including implied warranties for merchantability and implied
warranties for fitness, are valid only until Warranty Expiration Date as labeled on the
product. This Linear Corporation Warranty is in lieu of all other warranties express
or implied.
All products returned for warranty service require a Return Product Authorization
Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and
other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need
in portable wireless signaling. However, there are some limitations which must be
observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15
✶
devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals
✶
that occur on or near their operating frequencies, regardless of code settings.
Changes or modificati ons to the device may void FCC compliance.
✶
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
✶
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or
✶
dealer, and these facts should be communicated to the ultimate users.
Copyright © 1999 Linear Corporation 213071 B