Linear AE-1 User Manual

INTRODUCTION
1. SYSTEM COMPONENT LOCATIONS
The Model AE-1 Telephone Entry Control Console is designed for use as a primary access control device for gated communities, parking garages, office buildings,
apartments, dormitories, hotels/motels, commercial buildings and recreational facilities.
This unit is a fusion of Linear’s full-featured Model AM/II Access Control System and
AM/II ACCESS CONTROL SYSTEM
the Model AE-1 Telephone Entry Module. Housed in a locked, rugged stainless steel
Telephone Entry Control Console
enclosure, the AE-1 features a 12-key telephone style keypad, a backlit two-line directory display, and a built-in microphone and speaker.
All of the outstanding AM/II access control system functions are available with the AE-1 in addition to hands-free, full duplex telephone communications with tenants or authorized personnel for granting access. Entry codes can also be typed directly on the keypad.
In a typical installation, the unit’s memory would be programmed with each tenant’s name and directory code number. A visitor would use the the directory names and code number for the desired party. Upon entering the directory
or # key on the AE-1 to view
*
number, the AE-1 will automatically dial the tenant’s telephone number and establish two-way voice communication between the visitor and the tenant. The tenant will then have the option to grant access to the guest by pressing a digit on their telephone.
SPEAKER
In addition to the telephone entry, the AE-1 can grant access using various remote devices that are commonly used with the AM/II. These devices include wireless transmitters, proximity receivers, swipe card readers and remote keypads.
Mechanical & Electrical Installation Instructions
The output relays can be programmed to control electric door strikes, door & gate operators, barrier gates. CCTV cameras can also be triggered by the output relays to monitor the entry areas.
All of the programming functions of the AE-1 can be performed directly through the
(760) 438-7000 FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
unit’s keypad. An optional telephone modem can be installed for easy remote programming with a personal computer.
The AE-1 cabinet has provisions for installing a postal lock for keyed mail carrier access. The postal lock can be programmed to activate any of the four output relays.
POSTAL LOCK LOCATION (LOCK OPTIONAL)
2. AE-1 COMPONENT LOCATIONS 3. DETERMINE MOUNTING LOCATION 4. MOUNT CABINET
POSTAL LOCK SWITCH
MODEM (OPTIONAL)
AE-1 TELEPHONE ENTRY MODULE
MICROPHONE (HIDDEN)
TELEPHONE
MODULAR TELEPHONE JACK (HIDDEN)
HYBRID LEVEL ADJUSTMENT (FACTORY SET DO NOT ADJUST)
SPEAKER VOLUME ADJUSTMENT
SPEAKER CONNECTOR
AE-1 TO AM/II INTERCONNECT CABLE
ON-LINE INDICATOR (LIGHTS WHEN PHONE LINE IS ACTIVE)
LINE TERMINALS
MICROPHONE & POSTAL KEY SWITCH TERMINALS
TEST JUMPER (REMOVE TO HEAR UNIT DIAL)
BUSY INDICATOR (LIGHTS WHEN AE-1 IS COMMUNICATING OR WHEN PHONE LINE IS DISCONNECTED)
DISPLAY CONTRAST ADJUSTMENT
THE AE-1 SHOULD BE MOUNTED IN A WELL LIT LOCATION NEAR THE CONTROLLED OPENING. WIRING ACCESS FOR POWER, TELEPHONE, EARTH GROUND, CONTROL OUTPUT AND ANTENNA CO-AX MUST BE AVAILABLE BEHIND THE MOUNTING LOCATION.
AREA LIGHTING
AE-1 TELEPHONE ENTRY SYSTEM
CONTROLLED ENTRY DOOR
5 3/8" 5 3/8"
5 3/8" 5 3/8"
MOUNTING LOCATION
9 3/8"
MOUNT CABINET WITH SUITABLE HARDWARE FOR MOUNTING SURFACE.
USE TOGGLE BOLTS FOR STUCCO WALL, WEDGE ANCHORS OR EXPANSION BOLTS FOR CONCRETE WALL, LAG SCREWS FOR WOOD WALL.
5. CONNECT WIRING 6. OPTIONAL MODEM INSTALLATION 7. OPTIONAL POSTAL LOCK INSTALLATION
REFER TO THE AM/II INSTALLATION & PROGRAMMING INSTRUCTIONS FOR DETAILS ON WIRING POWER, EARTH GROUND, REMOTE DEVICES, ANTENNA, CONTROL INPUTS AND RELAY OUTPUTS TO THE AM/II
RELAY OUTPUT TO ACCESS DEVICE
POWER INPUT TO TRANSFORMER
EARTH GROUND CONNECTION
USE LOWER WIRING HOLE IF MODEM IS GOING TO BE INSTALLED
TELEPHONE LINE (USE MODULAR JACK OR TERMINALS)
CONNECT UNITS WITH THE MODEL A2M MODEM CABLE
CONNECT INCOMING TELEPHONE LINE TO THE MODEM'S "LINE" JACK
NOTE: SEPARATE PHONE LINES ARE RECOMMENDED FOR THE MODEM AND AE-1. ONE PHONE LINE CAN BE USED AS SHOWN ALTHOUGH THE ENTRY SYSTEM IS UNAVAILABLE WHILE MODEM IS ON-LINE.
ATTACH MODEM WITH VELCRO ® STRIPS
USE THE TELEPHONE CABLE SUPPLIED WITH THE MODEM TO CONNECT BETWEEN THE MODEM'S "PHONE" JACK AND THE AE-1 TELEPHONE LINE JACK
CONNECT MODEM TRANSFORMER POWER CABLE AND SLIDE MODEM POWER SWITCH TO "1"
1
BARRIER PLATE
BEND UP TABS ON THE HOLE PLUG AND REMOVE THE PLUG
3
REMOVE THE TWO NUTS AND THE POSTAL LOCK BARRIER PLATE
2
INSTALL THE POSTAL LOCK USING FOUR 10-32 NUTS
VERIFY THAT THE LOCK STRIKE ACTIVATES THE MICRO SWITCH
8. PROGRAM SYSTEM 9. ADJUST SPEAKER VOLUME & TESTING LINEAR LIMITED WARRANTY
INSTALLERS OF AE-1 SYSTEMS SHOULD FAMILIARIZE THEMSELVES WITH THE AM/II SYSTEM BY READING THE ENTIRE AM/II INSTALLATION & PROGRAMMING INSTRUCTIONS. PROGRAM AREAS SPECIFIC TO THE AE-1 ARE AREAS 07 &
27. AREA 21 HAS TWO OPTIONS FOR THE AE-1. PROGRAMMING WITH A PERSONAL COMPUTER IS RECOMMENDED, ESPECIALLY FOR ENTERING THE TENANT NAMES.
AREA 21
RELAY SETUP
Which Relay to Program. CH-A CH-B CH-C CH-D
Select Operation: Control Shunt Alarm Obstacle CCTV
Select Timing Mode: Time Pulse Toggle Latch
Enter Activation Time: Time in seconds: 00000
Assign Time Zone [1]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [2]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [3]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [4]: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Enter Channel Name
Assign Telephone Digit None 1 2 3 4 5 6 7 8 9
Channel Control Normal Activate LockOpen LockClosed
21.1
21.2
21.3
21.4
21.5
21.6
21.7
21.8
21.9
21.10
21.11
AREA 07
TELEPHONE ENTRY NUMBERS
Enter Directory Code Directory Code: 0000
Enter Tenant Name
Enter Telephone Number Telephone#: ************
Extended Talk Time Yes No
Delete Directory Entry Directory Code: 0000
AREA 27
TELEPHONE ENTRY SETUP
Directory Code Length 1 2 3 4
Directory Begins At Beginning(A) Middle(M)
PBX Dialing Digit Off 9 8 7 6 5 4 3 2 1 0
Set Talk Time Talk Time Seconds: 060
Assign Postal Key Door CH-A CH-B CH-C CH-D
Sort Directory Names Yes No
Edit Display Messages Message Number: 00
Edit Display Message
Max Directory Entries Maximum Entries: 00000
Delete All Tlph. Entries Yes No
Adjust Hybrid Level Press OK To Start/Stop
Display Briteness Dim Low Med High
Priority Access ABCD 0 = No 1 = Yes 0000
7.1
7.2
7.3
7.4
7.5
27.1
27.2
27.3
27.4
27.5
27.6
27.7
27.8
27.9
27.10
27.11
27.12
27.13
1
REMOVE TEST JUMPER
ADJUST THE SPEAKER VOLUME AND DISPLAY CONTRAST TO SUIT THE ENVRONMENT THE UNIT IS MOUNTED IN
3
5
VERIFY THAT THE PROPER RELAY ACTIVATES AND THAT THE ACCESS DOOR STRIKE OR GATE CONTROL ACTIVATES
2
PRESS # TO VIEW DIRECTORY AND ENTER CODE TO DIAL A TEST PHONE NUMBER
4
HAVE TESTING PARTY PRESS ASSIGNED TELEPHONE DIGIT (DEFAULT IS 9) TO GRANT ACCESS
6
REPLACE THE TEST JUMPER, LOCK THE CABINET AND INSTRUCT FACILITY MANAGER ON SYSTEM USE
This Linear product is warrant ed against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear
Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All
implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express
or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15
devices. As such, they have limited transmitter power and therefore limited range. A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals
that occur on or near their operating frequencies, regardless of code settings. Changes or modificati ons to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or
dealer, and these facts should be communicated to the ultimate users.
Copyright © 1999 Linear Corporation 213071 B