JIC SPECIFICATIONS
MODIFICATION
909204
APPLICATION
Modifies a door operator to generally meet JIC (Joint
Industry Conference) specifications for electrical equipment
in industrial locations (some minor exceptions are taken).
Includes TEFC motor, oiltight/dusttight rotary limit switches,
oiltight/dusttight 3-button control station, and separate
wall-mounted combination reversing starter. The starter is
an industrial size 1 with a fusible disconnect switch in a
NEMA 12 enclosure. The control circuit is 115VAC and the
operator supply voltage must be 460V - 3 phase (not
available on 115V or 230V operators).
Refer to the wiring diagram included with this addendum in
lieu of diagrams included with owner's manual.
NEMA 12 Limit Switch Enclosure
TEFC Motor
Industrial Size 1 with Fusible
Disconnect Switch in NEMA 12 Enclosure
To prevent possible SERIOUS INJURY or DEATH, safety
equipment MUST be used with operators employing this
modification.
1 PHASE SCHEMATIC DIAGRAM 1832-1
Power In
L2
BK
L1
BK
115V. Only
230V. Only
OR
P
BL
Y
GY
115V. Connection
NOTE: I.R. Coil voltage is the same as the line voltage.
W
CL
3
4
0/L
BK
BK
I.R.
Safety Edge
To Reverse
Open
Radio To Open
And Close
R1
Open And
Close
Close
4
GY
10 NC
R2
OR
OP
4
2OP1
CL
6
BR
W
BR
External
Interlock
Auxilary Close
Limit Switch
C
Y
Y
7
OR
R1
3
1
8
5
42
5OP6
5
Y
5
Y
3
Internal
Interlock
(When
provided)
GY
BL-BK
BL-BK
OR
C
GY
BL
P
Y
OR
1
NC
Auxilary Open
NC
P
2
P
Soleniod
115V. Brake
(When Required)
To
Motor
Hand Chain
Switch
(When
provided)
Y
I.R.
Limit Switch
I.R.
P
BL
Y
GY
interchange purple & gray wires.
PRI.
24 VAC.
SEC.
14
OP
13
Y
OR
R
R
1
8
5
4
230V. Connection
To reverse motor direction
A2
A1
OP
R1
24 VAC
DPDT
R1
P
A2
BL-BK
2
3
BL-BK
Open L/S
OR
NC
R
P
CL
A1
Soleniod
230V. Brake
(When Required)
Bypass
Switch
BL
NC
Lock Sensor
Switch
OR
C
Y
P
Close L/S
N.C.
NC
BL
C
CNO
RD
Wire Nut
R
R
R3
P
C
14
CL
13
R
NOTE: I.R. (Instant Reverse) relay is wired normally open and is held closed when motor is not running.