Feature Overview
SCREEN
The screen will display the time and temperature until the menu button is pressed, and then it will
display the menu options. If there is a problem with the garage door opener the screen will display the
Diagnostic Code.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned on
they will stay on until the LIGHT button is pressed again, or until the garage door opener is activated.
Once the garage door opener is activated the lights will turn off after the specified period of time (the
factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the door is in
motion. The duration of the light timing can be adjusted by accessing the menu using the navigation
buttons.
MOTION SENSOR
The motion sensor will automatically turn on the garage door opener lights when motion is detected.
The lights will come on for the set period of time, then shut off. The factory setting is on and set at
4-1/2 minutes.
LOCK
The LOCK feature is designed to prevent activation of the garage door opener from remote controls
while still allowing activation from the door control and keyless entry. This feature is useful for added
peace of mind when the home is empty (i.e. vacation).
SMART CONTROL PANEL
MODEL 880LM
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is NOT connected BEFORE installing door control.
• Connect ONLY to 12 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum height of
5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote control
transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no
obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path
of closing garage door.
Yellow
LEARN Button
®
TIMER-TO-CLOSE (TTC)
DO NOT enable TTC if operating a one-piece door. TTC is to be used ONLY with sectional doors.
Factory default is set to off. TTC can be set to automatically close your garage door from the fully
open position after a specified period of time (1, 5, 10 minute intervals or a custom setting up to 99
minutes). The garage door opener will beep and the lights will flash before closing the door. The
screen on the door control can display the status of the TTC. TTC WILL NOT work if the garage door
opener is operating by battery power or if the safety reversing sensors are misaligned. This feature is
NOT intended to be the primary method of closing the door. A keyless entry should be installed in
the event of an accidental lock out when using this feature.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door opener system stays in good working
condition. A maintenance alert message will display on the screen indicating the garage door opener
may be in need of maintenance.
The MAS feature MUST be activated at time of installation. The factory setting is off.
Safety
Reversing
Sensors
Smart Control
®
Panel
1
Installation
Install the door control within sight of the door at a minimum height of 5 feet (1.5 m) where small
children cannot reach, and away from the moving parts of the door. For gang box installations it is not
necessary to drill holes or install the drywall anchors. Use the existing holes in the gang box.
NOTE: Pre-wiring means that your garage already has wires installed for the door control.
6ABx1-1/4"
HARDWARE
Drywall Anchors
GANG BOXDRYWALL
6-32x1"
WIRE THE DOOR CONTROL
Unplug the garage door opener to
1
prevent the garage door opener from
activating during wiring.
Strip 7/16 inch (11 mm) of insulation
2
from one end of the wire and separate
the wires.
7/16" (11 mm)
Connect one wire to each of the two
3
screws on the back of the door control.
The wires can be connected to either
screw.
PRE-WIRED INSTALLATIONS: Choose any two
wires to connect, but make note of which wires
are used.
MOUNT THE DOOR CONTROL
Mark the location of the bottom mounting
1
hole and drill a 5/32 inch (4 mm) hole.
Install the bottom screw, allowing
2
1/8 inch (3 mm) to protrude from
the wall.
Position the bottom hole of the door
3
control over the screw and slide down
into place.
1
2
WIRE TO GARAGE DOOR OPENER
Lift the push bar up and mark the top
4
hole.
Remove the door control from the wall
5
and drill a 5/32 inch (4 mm) hole for
the top screw.
Position the bottom hole of the door
6
control over the screw and slide down
into place. Attach the top screw.
Close the push bar.
7
7
4
6
3
5
1
Strip 7/16 inch (11 mm) of insulation
from the end of the wire near the garage
door opener.
Connect the wire to the red and white
2
terminals on the garage door opener.
The wires can be connected to either
terminal.
To insert or release wire, push
in tab with screwdriver tip.
PRE-WIRED INSTALLATIONS: Connect the same
wires to the garage door opener that were
previously connected to the door control.
Reconnect power to the garage door
3
opener. If the door control has been
installed and wired correctly, a message
will display on the screen. To synchronize
the garage door opener and the door
control, press the push bar up to 3 times,
until the garage door opener activates.
The time and temperature will display on
the door control when the door control
and the garage door opener are
synchronized.
7/16" (11 mm)
RED
WHITE
WHITE
GREY
2