LiftMaster 8360 Owner's Manual

PREMIUM Series Garage Door Opener

User’s Guide

FOR RESIDENTIAL USE ONLY
.
Write down the following information for future reference:
Serial Number:
Date of Purchase:
Please read this guide and the enclosed safety materials carefully!
The door WILL NOT CLOSE unless the Protector System
properly aligned.
Periodic checks of the garage door opener are required to ensure safe operation.
This garage door opener is ONLY compatible with MyQ accessories.
DO NOT enable the Timer-to-Close feature if you are installing the garage door opener on a one-piece door. The Timer-to-Close is to be used ONLY with
sectional doors.
Attach enclosed warning labels to the location indicated on label.
®
is connected and
®
and Security 2.0™
CONTACT INFORMATION
Leave this Users Guide with the homeowner.
The images throughout this manual are for reference and your product may look different.
CONTENTS
Important Safety Instructions .........2-3
Operation....................................4
Using the Door Control..................5
Programming-Door Control Panel ....6
Programming - Remote Controls ......7
To Erase the Memory ...................7
To Open the Door Manually ............8
Battery Backup*..........................8
Adjustment ..................................9
Program the Travel .................... 10
Test the Safety Reversal System .... 11
Test the Protector System
Maintenance .............................. 12
Troubleshooting ...................... 13-14
Repair Parts .............................. 15
Warranty .................................. 16
The Chamberlain Group, Inc.
Elmhurst, Illinois 60126-1196
®
.......... 11
www.liftmaster.com
845 Larch Avenue
*If applicable.
WARNING
WARNING
WARNING WARNING

Important Safety Instructions

Safety Symbol and Signal Word Review

This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
Mechanical
Electrical
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. Install garage door opener ONLY on properly balanced and
3. ALL repairs to cables, spring assemblies and other hardware
4. Disable ALL locks and remove ALL ropes connected
5. Install garage door opener 7 feet (2.13 m) or more above
6. Mount the emergency release within reach, but at least 6 feet
7. NEVER connect garage door opener to power source until
8. NEVER wear watches, rings or loose clothing while installing
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
9. Install wall-mounted garage door control:
• within sight of the garage door.
lubricated garage door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
MUST be made by a trained door systems technician BEFORE installing opener.
to garage door BEFORE installing opener to avoid entanglement.
fl oor.
(1.83 m) above the fl oor and avoiding contact with vehicles to avoid accidental release.
instructed to do so.
or servicing opener. They could be caught in garage door or opener mechanisms.
• out of reach of children at minimum height of 5 feet (1.5 m).
• away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to garage door control.
11. Place manual release/safety reverse test label in plain view on inside of garage door.
12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid fl at) on the fl oor.
13. To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric and battery power BEFORE performing ANY service or maintenance.
14. DO NOT enable the Timer-to-Close functionality if operating either one-piece or swinging garage doors. To be enabled ONLY when operating a sectional door.
15.
SAVE THESE INSTRUCTIONS.
NOTE: For complete installation instructions visit www.liftmaster.com to print the entire owner’s manual.
2
WARNING
WARNING
WARNING WARNING
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel.
4. ALWAYS keep garage door in sight and away from people and objects until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPENED DOOR.
6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Use caution when using this release with the door open. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly and increasing the risk of SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If rope knot becomes untied, you could fall.
9. After ANY adjustments are made, the safety reversal system MUST be tested.
10. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or a 2x4 laid fl at) on the fl oor. Failure to adjust the garage door opener properly increases the risk of SEVERE INJURY or DEATH.
11. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
12. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.
13. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers.
14. This operator system is equipped with an unattended operation feature. The door could move unexpectedly. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
15. DO NOT enable the Timer-to-Close functionality if operating either one-piece or swinging garage doors. To be enabled ONLY when operating a sectional door.
16.
SAVE THESE INSTRUCTIONS.
3

Operation

Your garage door opener is equipped with features to provide you with greater control over your garage door operation. Accessories provided with your garage door opener will vary depending on the garage door opener model purchased.
ALERT2CLOSE
The Alert2Close feature provides a visual and an audible alert that an unattended door is closing.
TIMER-TO-CLOSE (TTC)
The Timer-to-Close feature automatically closes the door after a specifi ed time period that can be adjusted using a TTC enabled door control (Models 881LM or 880LM). Prior to and during the door closing the garage door opener lights will fl ash and the garage door opener will beep.
®
MyQ
MyQ® technology uses a 900MHz signal to provide two-way communication between the garage door opener and MyQ® enabled accessories. Your garage door opener is compatible with up to 16 MyQ® accessories.
REMOTE CONTROLS AND DOOR CONTROLS (SECURITY 2.0™)
Your garage door opener has already been programmed at the factory to operate with your remote control, which changes with each use, randomly accessing over 100 billion new codes. Compatible with MyQ® and Security 2.0™.
NOTE: Older LiftMaster remote controls, door controls, and third party products are not compatible.
Accessories (Security 2.0™) Remote Controls Door Controls
Keyless Entries
Up to 24 Up to 2 Smart Control Panels or 4 of any other
Security+ 2.0™ door controls Up to 2
THE PROTECTOR SYSTEM® (SAFETY REVERSING SENSORS)
When properly connected and aligned, the safety reversing sensors will detect an obstruction in the path of the infrared beam. If an obstruction breaks the infrared beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will fl ash 10 times. If the door is fully open, and the safety reversing sensors are not installed, or are misaligned, the door will not close from a remote control. However, you can close the door
MEMORY CAPACITY
if you hold the button on the door control or keyless entry until the door is fully closed. The safety reversing sensors do not affect the opening cycle.
ENERGY CONSERVATION
For energy effi ciency the garage door opener will enter sleep mode when the door is fully closed. The sleep mode shuts the garage door opener down until activated. The sleep mode is sequenced with the garage door opener light bulb; as the light bulb turns off the sensor LEDs will turn off and whenever the garage door opener lights turn on the sensor LEDs will light.
LIGHTS
The garage door opener light bulbs will turn on when the opener is initially plugged in; power is restored after interruption, or when the garage door opener is activated. The lights will turn off automatically after 4-1/2 minutes. An incandescent A19 light bulb (100 watt maximum) or for maximum energy effi ciency a 26W (100W equivalent) compact fl uorescent light (CFL bulb may be used.
Light Feature
The garage door opener is equipped with an added feature; the lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken. For added control over the light bulbs on your garage door opener, see page 6.
USING YOUR GARAGE DOOR OPENER
The garage door opener can be activated through a wall-mounted door control, remote control, wireless keyless entry or MyQ® accessory. When the door is closed and the garage door opener is activated the door will open. If the door senses an obstruction or is interrupted while opening the door will stop. When the door is in any position other than closed and the garage door opener is activated the door will close. If the garage door opener senses an obstruction while closing, the door will reverse. If the obstruction interrupts the sensor beam the garage door opener lights will blink 10 times. However, you can close the door if you hold the button on the door control or keyless entry until the door is fully closed. The safety reversing sensors do not affect the opening cycle. The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
4
Operation

Using the Door Control

SYNCHRONIZE THE DOOR CONTROL
To synchronize the door control to the garage door opener, press the push bar until the garage door opener activates (it may take up to 3 presses). Test the door control by pressing the push bar, each press of the push bar will activate the garage door opener.
MOTION-DETECTING CONTROL PANEL
Push Bar
Service LED
LEARN Button
LOCK Button
Light Button
MULTI-FUNCTION CONTROL PANEL
Push Bar
Service LED
LEARN Button
LOCK Button Command LED
Light Button
The control panel will vary depending on the garage door opener model purchased.
PUSH BAR
Press the push bar to open and close the door.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned on they will stay on until the LIGHT button is pressed again, or until the garage door opener is activated. Once the garage door opener is activated the lights will turn off after the specifi ed period of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the door is in motion. The duration of the light timing can be adjusted using the door control, see page 6.
The following features are accessible by lifting the push bar: LEARN A DEVICE
Any compatible remote controls, wireless keyless entry, or MyQ® accessories can be programmed to the garage door opener by pressing the Learn button.
LOCK
The LOCK feature is designed to prevent activation of the garage door opener from remote controls while still allowing activation from the door control and keyless entry. This feature is useful for added peace of mind when the home is empty (i.e. vacation).
AUTOMATIC LIGHT Motion Sensor (Motion-Detecting Control Panel)
Factory default is set to on. This feature automatically turns on the garage door opener lights when motion is sensed. The lights will come on for the set period of time, then shut off. If using the garage door opener light as a work light disable the motion sensor, otherwise the light will turn off automatically if you are beyond the range of the sensor.
Light Feature
The lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door opener system stays in good working condition. When the garage door opener needs to be serviced (approximately 4500 garage door opener cycles) the command (yellow) and service (red) LEDs will begin to alternately fl ash back and forth. The factory setting for the MAS feature is off and can be activated at time of installation. Contact your installing dealer for service.
5
Operation
Programming
MOTION-DETECTING CONTROL PANEL
Motion Sensor Switch
Service LED
LEARN Button
LOCK Button
Command LED
MULTI-FUNCTION CONTROL PANEL
Service LED
LEARN Button
LOCK Button
Motion Sensor
Command LED
LIGHT Button
LIGHT Button
Features Lock
NOTE: Your remote controls will NOT work when LOCK mode is active however your keyless entry will still allow access to your garage.
Activate: Press and hold the LOCK button for 2 seconds. The command LED will flash as long as the lock feature is activated and your handheld remote control will not operate your door at this time. Deactivate: Press and hold the LOCK button again for 2 seconds. The command LED will stop flashing and normal operation will resume.
Light To change the amount of time the garage door opener lights will stay on:
Press and hold the LOCK button until the garage door opener lights fl ash.* The time interval is indicated by the number of fl ashes.
NUMBER OF TIMES GARAGE DOOR OPENER LIGHTS FLASH
TIME THE GARAGE DOOR OPENER LIGHT STAYS ON
123 4
1 ½ Minutes 2 ½ Minutes 3 ½ Minutes 4 ½ Minutes
To cycle through the time intervals repeat the step above.
Deactivate: Press and hold the LIGHT button until the garage door opener lights turn on, then off again.* Activate: Start with the garage door opener lights on. Press and hold the LIGHT button until the garage door opener lights turn off, then
on again.*
* Approximately 10 seconds
Motion Sensor
Activate/Deactivate: Slide the motion sensor switch ON or OFF. (Motion-Detecting Control Panel)
To Program a Remote Control or Keyless Entry
1. Press the LEARN button on the door control to enter Programming Mode.
2. Press the LEARN button again, the LED will fl ash once.
3. Remote Control: Press the button on the remote control that you wish to operate your garage door. Keyless Entry: Enter a 4-digit personal identifi cation number (PIN) of your choice on the keyless entry keypad. Then press the ENTER button.
The garage door opener lights will fl ash (or two clicks will be heard) when the code has been programmed. If programming is unsuccessful, repeat steps 1-3 or program the remote using the learn button on the garage door opener.
Maintenance Alert System (MAS)
Activate/Deactivate
Press and hold the LEARN button. Then press the LIGHT button. The service LED will fl ash the status; Active is 2 fl ashes and deactivated is 3 fl ashes.
6
Operation

Programming - Remote Controls

Your garage door opener has been programmed at the factory to operate with your remote control. Older LiftMaster remote controls are NOT compatible. Programming can be done
through the door control or the Learn button on the garage door opener. To program additional remote controls refer to the instructions provided with the additional remote controls or visit www.liftmaster.com. If your vehicle is equipped with a Homelink®, you may require an external adapter depending on the make, model, and year of your vehicle. Visit www.homelink.com for additional information.
PROGRAM A REMOTE USING THE LEARN BUTTON ON THE GARAGE DOOR OPENER
1 Press and release the Learn button on the garage
door opener. The Learn indicator light will glow steadily for 30 seconds.
When replacing the light lens cover, ensure the antenna wires are hanging straight down.
Learn Indicator Light
Yellow Learn Button
ERASE ALL REMOTE CONTROLS AND KEYLESS ENTRIES
1 Press and hold the learn button on garage door opener until the learn LED goes out
(approximately 6 seconds). All remote control and keyless entry codes are now erased.
Reprogram any accessory you wish to use.
ERASE ALL DEVICES (Including MyQ® enabled accessories)
1 Press and hold the learn button on garage door opener until the learn LED goes out
(approximately 6 seconds).
2 Immediately press and hold the learn button again until the learn LED goes out. All codes
are now erased.
Reprogram any accessory you wish to use.
2 Within 30 seconds, press and hold
the button on the remote control.
7
3 Release the button when the
garage door opener light blinks. It has learned the code. If light bulbs are not installed, two clicks will be heard.
Operation

To Open the Door Manually

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.

Battery Backup (If applicable)

The battery backup system allows access in and out of your garage, even when the power is out. When the garage door opener is operating on battery power, the garage door opener will run slower, the light will not function, the Battery Status LED will glow solid orange, and a beep will sound approximately every 2 seconds.
The battery charges when the garage door opener is plugged into a 110Vac electrical outlet that has power and requires 24 hours to fully charge. A fully charged battery supplies 12Vdc to the garage door opener for one to two days of normal operation during an electrical power outage. After the electrical power has been restored, the battery will recharge within 24 hours. The battery will last approximately 1 to 2 years with normal usage. Instructions for replacement are provided with the battery. To obtain maximum battery life and prevent damage, disconnect the battery when the garage door opener is unplugged for an extended period of time.
NOTE: When the garage door opener is in battery backup mode the garage door opener lights, Timer-to-Close, and Remote Close features are unavailable.
BATTERY STATUS LED
NOTE: The Battery Status LED is most visible with the garage door opener light off. Battery does not have to be fully charged to operate the garage door opener.
Battery Status LED
GREEN LED:
All systems are normal.
• A solid green LED light indicates the battery is fully charged.
• A fl ashing green LED indicates the battery is being charged.
DISCONNECT THE TROLLEY
1 The door should be fully closed if possible. 2 Pull down on the emergency release handle.
RECONNECT THE TROLLEY
The lockout feature prevents the trolley from reconnecting automatically.
1 Pull the emergency release handle down and back (toward
the opener). The door can then be raised and lowered manually as often as necessary.
2 To disengage the lockout feature, pull the handle straight
down.
The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote control.
ORANGE LED:
The garage door opener has lost power and is in battery backup mode.
• A solid orange LED with beep, sounding approximately every 2 seconds, indicates the garage door opener is operating on battery power.
• A fl ashing orange LED with beep, sounding every 30 seconds, indicates the battery is low.
8
RED LED:
The garage door opener’s 12V battery needs to be replaced.
• A solid red LED with beep, sounding every 30 seconds, indicates the garage door opener needs servicing. Please call for replacement battery to allow your system to operate during a power outage.

Adjustment

Introduction

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
Your garage door opener is designed with electronic controls to make setup and adjustments easy. The adjustments allow you to program where the door will stop in the open (UP) and close (DOWN) position. The electronic controls sense the amount of force required to open and close the door.
NOTE: If anything interferes with the door’s upward travel it will stop. If anything interferes with the door’s downward travel, it will reverse.
To watch a short instructional video on programming your new garage door opener use your smartphone to read the QR Code below:
UP (Open)
DOWN (Close)
PROGRAMMING BUTTONS
UP Button
PROGRAMMING BUTTONS
The programming buttons are located on the left side panel of the garage door opener and are used to program the travel.
Adjustment Button
DOWN Button
9
Adjustment

Program the Travel

1
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
1.1 Press and hold the Adjustment
Button until the UP Button begins to fl ash and/or a beep is heard.
1.5 Once the door is in the desired
DOWN position press and release the Adjustment Button. The garage door opener lights will fl ash twice and the UP Button will begin to fl ash.
1.2 Press and hold the UP Button
until the door is in the desired UP position.
NOTE: The UP and DOWN Buttons can be used to move the door up and down as needed.
1.6 Press and release the UP Button.
When the door travels to the programmed UP position, the DOWN Button will begin to fl ash.
1.3 Once the door is in the desired
UP position press and release the Adjustment Button. The garage door opener lights will fl ash twice and the DOWN Button will begin to fl ash.
1.7 Press and release the DOWN
Button. The door will travel to the programmed DOWN position. Programming is complete.
10
1.4 Press and hold the DOWN Button
until the door is in the desired DOWN position.
NOTE: The UP and DOWN Buttons can be used to move the door up and down as needed.
* If the garage door opener lights are
fl ashing 5 times during the steps for Program the Travel, the programming has timed out. If the garage door opener lights are fl ashing 10 times during the steps for Program the Travel, the safety reversing sensors are misaligned or obstructed. When the sensors are aligned and unobstructed, cycle the door through a complete up and down cycle using the remote control or the UP and DOWN buttons. Programming is complete. If you are unable to operate the door up and down, repeat the steps for Programming the Travel.