Liftmaster 8075, 8160, 8155, 8065 User Manual

USER’S GUIDE
FOR RESIDENTIAL USE ONLY

CONTRACTOR Series Garage Door Opener

MODELS 8155 • 8160 • 8165 • 8065 • 8075
• Please read this guide and the enclosed safety materials carefully!
• The door WILL NOT CLOSE unless the Protector System®
is connected and properly aligned.
safe operation.
• This garage door opener is ONLY compatible with MyQ®
and Security+ 2.0® accessories.
• DO NOT install on a one-piece door if using devices or features
providing unattended close. Unattended devices and features are to be used ONLY with sectional doors.
• Attach enclosed warning labels to the location indicated on label.
Register your garage door opener to receive
updates and offers from LiftMaster
Take a photo of the camera icon
including the points ( ).
Send it in by texting the photo to 71403 (US) or visit www.liftmaster.photo (Global)
Elmhurst, Illinois 60126-1196
LiftMaster.com
LiftMaster
845 Larch Avenue

Contents

Important Safety Instructions ............................3-4
Operation...................................................... 5
Using the Door Control.................................... 6
Programming - Push Button Door Control ............. 6
Programming - Multi-Function Control Panel ......... 7
Programming - Remote Controls ........................ 8
To Erase the Memory ..................................... 8
To Open the Door Manually .............................. 9
Adjustment ...................................................10
Program the Travel ....................................... 11
Test the Safety Reversal System ....................... 12
Test the Protector System
Maintenance .................................................13
Troubleshooting .........................................14-15
Repair Parts .................................................16
Accessories .................................................. 17
Registration..................................................17
Warranty .....................................................18
Write down the following information for future reference:
Serial Number:
Date of Purchase:
®
............................. 12
.

Safety Symbol and Signal Word Review

This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
Mechanical
Electrical
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.
Unattended Operation
The Timer-to-Close (TTC) feature, the MyQ® Smartphone Control app, and MyQ® Garage Door and Gate Monitor are examples of unattended close and are to be used ONLY with sectional doors. Any device or feature that allows the door to close without being in the line of sight of the door is considered unattended close. The Timer-to-Close (TTC) feature, the MyQ® Smartphone Control, and any other MyQ® devices are to be used ONLY with sectional doors.
CONTACT INFORMATION
Leave this Users Guide with the homeowner.
The images throughout this manual are for reference and your product may look different.
2
WARNING
WARNING
WARNING

Important Safety Instructions

IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or more above fl oor.
6. Mount the emergency release within reach, but at least 6 feet (1.83 m) above the fl oor and avoiding contact with vehicles to avoid accidental release.
7. NEVER connect garage door opener to power source until instructed to do so.
8. NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
NOTE: For complete installation instructions visit LiftMaster.com to print the entire owner’s manual.
10. Place entrapment warning label on wall next to garage door control.
11. Place manual release/safety reverse test label in plain view on inside of garage door.
12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid fl at) on the fl oor.
13. To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric and battery power BEFORE performing ANY service or maintenance.
14. DO NOT install on a one-piece door if using devices or features providing unattended close. Unattended devices and features are to be used ONLY with sectional doors.
15.
SAVE THESE INSTRUCTIONS.
3
Important Safety Instructions
WARNING
WARNING
WARNING
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel.
4. ALWAYS keep garage door in sight and away from people and objects until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPENED DOOR.
6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Use caution when using this release with the door open. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly and increasing the risk of SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If rope knot becomes untied, you could fall.
9. After ANY adjustments are made, the safety reversal system MUST be tested.
10. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or a 2x4 laid fl at) on the fl oor. Failure to adjust the garage door opener properly increases the risk of SEVERE INJURY or DEATH.
11. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
12. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.
13. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers.
14. This operator system is equipped with an unattended operation feature. The door could move unexpectedly. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
15. DO NOT install on a one-piece door if using devices or features providing unattended close. Unattended devices and features are to be used ONLY with sectional doors.
16.
SAVE THESE INSTRUCTIONS.
4

Operation

Your garage door opener is equipped with features to provide you with greater control over your garage door operation.

ALERT2CLOSE

The Alert2Close feature provides a visual and an audible alert that an unattended door is closing.

TIMER-TO-CLOSE (TTC)

The Timer-to-Close feature automatically closes the door after a specifi ed time period that can be adjusted using a TTC enabled door control (Models 881LMW or 880LM). Prior to and during the door closing the garage door opener lights will fl ash and the garage door opener will beep.
®
MyQ
MyQ® technology uses a 900MHz signal to provide two­way communication between the garage door opener and MyQ® enabled accessories. Your garage door opener is compatible with up to 16 MyQ® accessories.
SECURITY+ 2.0
®
REMOTE CONTROLS AND DOOR
CONTROLS
Your garage door opener has already been programmed at the factory to operate with your remote control, which changes with each use, randomly accessing over 100 billion new codes. Compatible with MyQ
®
and
Security+ 2.0® accessories, see page 17.
NOTE: Older LiftMaster remote controls, door controls, and third party products are not compatible.
Security+ 2.0 Accessories
®
MEMORY CAPACITY
Remote Controls Up to 12 Door Controls Up to 2 Smart Control Panels or 4
of any other Security+ 2.0
®
door
controls
Keyless Entries Up to 1
®
THE PROTECTOR SYSTEM
(SAFETY REVERSING
SENSORS)
When properly connected and aligned, the safety reversing sensors will detect an obstruction in the path of the infrared beam. If an obstruction breaks the infrared beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will fl ash 10 times. If the door is fully open, and the safety reversing sensors are not installed, or are misaligned, the door will not close from a remote control. However, you can close the door if you hold the button on the door control or keyless entry until the door is fully closed. The safety reversing sensors do not affect the opening cycle.

ENERGY CONSERVATION

For energy effi ciency the garage door opener will enter sleep mode when the door is fully closed. The sleep mode shuts the garage door opener down until activated. The sleep mode is sequenced with the garage door opener light bulb; as the light bulb turns off the sensor LEDs will turn off and whenever the garage door opener lights turn on the sensor LEDs will light. The garage door opener will not go into the sleep mode until the garage door opener has completed 5 cycles upon power up.

LIGHTS

The garage door opener light bulbs will turn on when the opener is initially plugged in; power is restored after interruption, or when the garage door opener is activated. The lights will turn off automatically after 4-1/2 minutes. An incandescent A19 light bulb (100 watt maximum) or for maximum energy effi ciency a 26W (100W equivalent) compact fl uorescent light (CFL) bulb may be used.
Light Feature
The garage door opener is equipped with an added feature; the lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken. For added control over the light bulbs on your garage door opener.

USING YOUR GARAGE DOOR OPENER

The garage door opener can be activated through a wall-mounted door control, remote control, or wireless keyless entry. When the door is closed and the garage door opener is activated the door will open. If the door senses an obstruction or is interrupted while opening the door will stop. When the door is in any position other than closed and the garage door opener is activated the door will close. If the garage door opener senses an obstruction while closing, the door will reverse. If the obstruction interrupts the sensor beam the garage door opener lights will blink 10 times. However, you can close the door if you hold the button on the door control or keyless entry until the door is fully closed. The safety reversing sensors do not affect the opening cycle. The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
5
Operation

Using the Door Control

SYNCHRONIZE THE DOOR CONTROL
To synchronize the door control to the garage door opener, press the push bar or push button until the garage door opener activates (it may take up to 3 presses). Test the door control by pressing the push bar or push button, each press of the push bar or push button will activate the garage door opener.
Push Bar
SERVICE LED
LEARN Button
LOCK Button
COMMAND LED
LIGHT Button
Push Button
Light Button
LOCK
The LOCK feature is designed to prevent activation of the garage door opener from remote controls while still allowing activation from the door control and keyless entry. This feature is useful for added peace of mind when the home is empty (i.e. vacation).
AUTOMATIC LIGHT Light Feature
The lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door opener system stays in good working condition. When the garage door opener needs to be serviced (approximately 4500 garage door opener cycles) the command (yellow) and service (red) LEDs will begin to alternately fl ash back and forth. The factory setting for the MAS feature is off and can be activated at time of installation. Contact your installing dealer for service.
Programming - Push Button Door Control
Push Button
Light Button
PUSH BAR OR PUSH BUTTON
Press the push bar or push button to open or close the door.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned on they will stay on until the LIGHT button is pressed again, or until the garage door opener is activated. Once the garage door opener is activated the lights will turn off after the specifi ed period of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the door is in motion.
The following features are accessible by lifting the push bar (multi-function door control only):
LEARN A DEVICE
Any compatible remote controls or wireless keyless entries can be programmed to the garage door opener by pressing the LEARN button on the Multi-Function Control Panel.
Feature To Program
a Remote Control or Keyless Entry
6
1. Press and hold the Light button and the Push button until the Push button LED begins to blink.
2. Remote Control: Press the button on the remote control that you wish to operate your garage door. Keyless Entry: Enter a 4-digit personal identifi cation number (PIN) of your choice on the keyless entry keypad. Then press the ENTER button.
The garage door opener lights will fl ash (or two clicks will be heard) when the code has been programmed.
Operation

Programming - Multi-Function Control Panel

Service LED
LEARN Button
LOCK Button
Features Lock NOTE: Your remote controls will NOT work when LOCK mode is active however your keyless entry will
Light To change the amount of time the garage door opener lights will stay on (default time is 4-1/2
To Program a Remote Control or Keyless Entry
Maintenance Alert System (MAS)
still allow access to your garage.
Activate: Press and hold the LOCK button for 2 seconds. The command LED will fl ash as long as the lock feature is activated and your handheld remote control will not operate your door at this time. Deactivate: Press and hold the LOCK button again for 2 seconds. The command LED will stop fl ashing and normal operation will resume.
Minutes):
Press and hold the LOCK button until the garage door opener lights fl ash.* The garage door opener lights will then indicate the current light duration by fl ashing up to 4 times (see table below).
NUMBER OF TIMES GARAGE DOOR OPENER LIGHTS FLASH 1234
TIME THE GARAGE DOOR OPENER LIGHT STAYS ON 1½ Minutes 2½ Minutes 3½ Minutes 4½ Minutes
To change the light duration time repeat the steps above until the lights fl ashes indicate your desired time frame.
NOTE: Factory setting is on.
This feature will turn on the garage door opener lights when the safety reversing sensors beam has been broken. Deactivate: Start with the garage door opener lights off. Press and hold the LIGHT button to turn on the light, continue to hold until the light turns off.* Activate: Start with the garage door opener lights on. Press and hold the LIGHT button to turn off the light, continue to hold until the light turns on.*
* Approximately 10 seconds
1. Press the LEARN button on the door control twice. The Command LED will blink.
2. Remote Control: Press and release the button on the remote control that you wish to operate your
garage door. Keyless Entry: Enter a 4-digit personal identifi cation number (PIN) on the keypad. Then press the
ENTER button. The garage door opener lights will fl ash (or two clicks will be heard) and the Command LED will stop blinking when the code has been programmed.
Activate/Deactivate
NOTE: Factory setting is on.
Press and hold the LEARN button. Then press the LIGHT button. The service LED will fl ash the status; Activated is 2 fl ashes and deactivated is 3 fl ashes.
Command LED
LIGHT Button
7
Operation

Programming - Remote Controls

Your garage door opener has been programmed at the factory to operate with your remote control. Older LiftMaster
remote controls are NOT compatible. Programming can be done through the door control or the Learn button on the garage door opener. To program additional remote controls refer to the instructions provided with the additional remote controls or visit LiftMaster.com. If your vehicle is equipped with HomeLink®, a Compatability BridgeTM (not included) may be necessary for certain vehicles. Visit bridge.LiftMaster.com to fi nd out if a Bridge is needed.
NOTE: The products illustrated in the instructions are for reference. Your product may look different.
PROGRAM A REMOTE USING THE LEARN BUTTON ON THE GARAGE DOOR OPENER
1 Locate the Learn button.
3 Press and hold the button on the remote control that
you wish to use.
Release the button when the garage door opener
lights blink or two clicks are heard.
If programming to other products, press the button a
second time to activate products.
ERASE ALL DEVICES (INCLUDING MYQ® ENABLED ACCESSORIES)
2 Press and immediately release the Learn button.
The Learn LED will glow steady for 30 seconds. Within 30 seconds...
“click”
“click”
1 Press and hold the learn button on garage door opener until the learn LED goes out (approximately 6 seconds). 2 Immediately press and hold the learn button again until the learn LED goes out. All codes are now erased.
Reprogram any accessory you wish to use.
8
Operation

To Open the Door Manually

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
DISCONNECT THE TROLLEY
1 The door should be fully
closed if possible.
2 Pull down on the emergency
release handle.
RECONNECT THE TROLLEY
The lockout feature prevents the trolley from reconnecting automatically.
1 Pull the emergency release
handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary.
2 To disengage the lockout feature, pull the handle
straight down. The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote control.
9

Adjustment

Introduction

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
Your garage door opener is designed with electronic controls to make setup and adjustments easy. The adjustments allow you to program where the door will stop in the open (UP) and close (DOWN) position. The electronic controls sense the amount of force required to open and close the door.
NOTE: If anything interferes with the door’s upward travel it will stop. If anything interferes with the door’s downward travel, it will reverse.
To watch a short instructional video on programming your new garage door opener use your smartphone to read the QR Code below:
UP (Open)
PROGRAMMING BUTTONS
The programming buttons are located on the left side panel of the garage door opener and are used to program the travel.
PROGRAMMING BUTTONS
10
DOWN (Close)
UP Button
Adjustment Button
DOWN Button
Adjustment

Program the Travel

1
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
1.1 Press and hold the
Adjustment Button until the UP Button begins to fl ash and/or a beep is heard.
1.3 Once the door is in the
desired UP position press and release the Adjustment Button. The garage door opener lights will fl ash twice and the DOWN Button will begin to fl ash.
1.5 Once the door is in the
desired DOWN position press and release the Adjustment Button. The garage door opener lights will fl ash twice and the UP Button will begin to fl ash.
1.2 Press and hold the UP Button until the door is
in the desired UP position.
NOTE: The UP and DOWN Buttons can be used to move the door up and down as needed.
1.4 Press and hold the DOWN Button until the door
is in the desired DOWN position.
NOTE: The UP and DOWN Buttons can be used to move the door up and down as needed.
1.6 Press and release the UP Button. When the door
travels to the programmed UP position, the DOWN Button will begin to fl ash.
1.7 Press and release the DOWN Button. The door
will travel to the programmed DOWN position. Programming is complete.
If the garage door opener lights are fl ashing 5 times during the steps for Program the Travel, the programming has timed out. If the garage door opener lights are fl ashing 10 times during the steps for Program the Travel, the safety reversing sensors are misaligned or obstructed. When the sensors are aligned and unobstructed, cycle the door through a complete up and down cycle using the remote control or the UP and DOWN buttons. Programming is complete. If you are unable to operate the door up and down, repeat the steps for Program the Travel.